Air volumes @planning:building_services:ventilation:basics
5 Hits, Last modified: 6 years ago
]] whose output is based on the number of people (30 m³/h per person), there are hardly any complaints... utomatically return to the "Normal" setting after 30-45 minutes, the "Minimal" setting should ensure t... With ordinary moisture sources in the household (330 g/h – varying individually) and “standard“ ventil... y this is acceptable.\\ (Air quantity per person 30 m³/h based on DIN 1946,\\ air changes based on ai
Ventilation
3 Hits, Last modified: 18 months ago
n:hausgrafik_lueftung_daemmung_2023_en.jpg?nolink&300x305|The basic principle of Passive House ventila... ventilation system should be designed to provide 30m<sup>3</sup> of fresh air per person per hour. For a living space of 30m<sup>2</sup> per person, this equates to a supp
Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
2 Hits, Last modified: 2 years ago
eper 2007] measured a seasonal efficiency of 8.9 (30 BTU/(Wh)). Some manufacturers suggest to replace... occupancy is 35 m²/person and fresh air supply is 30 m³/(h*person). As a reference, the buildings are
Compact HVAC systems
1 Hits, Last modified: 5 years ago
Supplying Passive Houses with sustainable energy @planning:building_services:heating_and_dhw
1 Hits, Last modified: 11 years ago
Basics @planning:building_services:ventilation
1 Hits, Last modified: 7 years ago
em whose output is based on the number of people (30 m³/h per person), there are hardly any complaints
Differentiation between Vv and Vn50 values @planning:building_services:ventilation
1 Hits, Last modified: 2 years ago
Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
1 Hits, Last modified: 6 years ago
Types of ventilation @planning:building_services:ventilation:basics
1 Hits, Last modified: 23 months ago
heat loss without heat recovery is between 20 and 30 kWh/(m²a) in apartments with adequate ventilation