Fulltext results:
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
- rest rate 2%, * financial assessment period = 30 years, * no Residual Value, * heating and... from €22/tCO2 for 2016-2019 to €100/tCO2 after 2030. The declared CO2 content of the electricity mix ... sement windows, inward opening – 12m² gross area, 30 year investment period, 30 year product lifetime) gives a similar annual cost for triple glazing than
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
- Component Award 2016: Affordable ventilation solutions for retrofits
- noise levels of ≤ 25 dB(A) in a living room and ≤ 30 dB(A) in a functional room). For volume air flows... must not exceed ≤ 25 dB(A) in living rooms and ≤ 30 dB(A) in functional rooms. If the device itself d
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
- egree, the light transmission can vary from 10 to 30%, which is normally the optimal range for interio... | Opaque || 10% transp. || 20% transp. || 30% transp. || | |U<sub>value</sub> |g<sub>value</
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- ssigkeit von Baustoffen und Baukonstruktionen, gi 30 (1928). Raisch, E.: Air permeability of building materials and structures, gi 30 (1928). \\ **[Sedlbauer 2002]** Sedlbauer, K.; G
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
- :primary_energy_renewable_per_chart_in_phpp_9.png?300 | Figure 7: Primary Energy Renewable (PER) chart
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
- ard) and electricity consumption to approximately 30 kWh/(m2a). * Achieve a highly comfortable ind
- Windows in a step-by-step retrofit
- 3 Shading/blinds ==== [{{ :picopen:fig_2_win.png?300|Figure 2: Existing roller shutter boxes should b
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- \ |{{ :picopen:blowerdoor_bild01_en_mit_logo.png?300 }}|{{ :picopen:blowerdoor_bild02_en_mit_logo.png?300 }}| |//**Figure 1: Basic measurement setup for... ntrast, the actual test normally takes only about 30 to 40 minutes, therefore saving time here wouldn’... ing on the type of construction, there are 150 to 300 m of leak-prone component connections [[.:airtig
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- loor was dug out and replaced by a new floor with 300mm FOAMGLAS® insulation in all rooms. As in many
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- ing roof overhang will usually be too short for a 30 cm insulation layer. Alternatively, if the roof i