Fulltext results:
- Certification of buildings in which the ground floor is used for commercial purposes (for PHPP 9, revised 5-Sep-2016)
- em boundary and is assumed as adiabatic. In the stairwell area etc. the boundary can also be at the ceiling level even if an air space exists here in part (the system boundary do... not have to continue down to the ground in the stairwell area). c) In addition, a separate PHPP calcu... eneral values for internal heat gains (3.5 W/m²), air change rate (0.4- fold) and heat recovery efficie
- Sample Documents for Building Certification @certification:certified_passive_houses
- cord of an {{ :picopen:blowerdoortest_report.pdf |airtightness test}} according to EN 13829, Method A ... open:blowerdoortest_report_according_iso9972.pdf |airtightness test}} according to ISO9972:2018-12 Co... cumenting a {{:picopen:thermal_bridges_to_ambient_air.pdf|thermal bridge calculation}} for a connection detail adjacent to ambient air Guidance on documenting the calculation of a win
- Evaluation of server and server room efficiency for non-residential buildings that exceed the primary energy criterion
- ver rooms (warm/cold aisle encasing and optimised air flow) and if possible, reliance must be placed on open air cooling with fresh air supply (instead of a fully air-conditioned system). However, these guidelines presuppose a separate s
- Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
- rposes indoors. Useful energy demand for cooling, airtightness, and criteria for comfort and hygiene ar... nnual heating demand of 11 kWh/(m²TFA*a). With an airtightness of 0.14 h-1, it is also very well built.... evaluation changes considerably. Variant 3 has an air-air heat pump that reduces PER demand to 40 kWh/(m²TFA*a). The level of Passive House Plus is then rea
- EnerPHit – the Passive House Certificate for retrofits
- nt_with_passive_house_components:thermal_envelope:airtightness|improved airtightness]] {{:picopen:members_only.png?20}} * use of high quality [[:planning:... ilation#the_convenient_solutionsupply_and_exhaust_air_systems_with_heat_recovery|ventilation with highl
- PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
- . Short-term storage can technically be achieved fairly efficiently, whilst longer term seasonal storag... ty. The profile of the hydropower electricity is fairly constant throughout the year and takes into acc... feature lower PER factors, as this RE source is fairly constant throughout the year. ==== Regional P
- Building Criteria: Overview of Changes
- unt of unplanned deviations in construction, e.g. airtightness level not meeting the requirements. =
- Certification of terraced houses and semi-detached/duplex houses according to Passive House Institute criteria
- uses when dimensioning the heating system (supply air heating alone may not be sufficient). The end-o
- Building Certification
- a functioning building at the construction site: Airtightness, thermal bridge free design, high-qualit
- The Passive House Classes: Classic, Plus and Premium
- energy demand for heating and cooling, as well as airtightness and comfort criteria). The assessment of
- Certification of Passive House office buildings @certification:certified_passive_houses
- rms of the primary energy demand and will also impair the thermal comfort in summer:\\ \\ A higher occ