Fulltext results:
- Outdoor thermography @planning:thermal_protection:thermal_protection_works
- images are rather revealing: * ** The outdoor air temperature is approx. 6.46 °C ** as measured at ... eached a temperature equilibrium with the outdoor air; therefore they neither give off heat nor do they... re difference between this object and the outdoor air temperature**. \\ In this case, the difference is... en delivered.**//|\\ \\ That morning, the outdoor air temperature is approx. 3.5 degrees Celsius. The u
- Types of glazing and their specific values @planning:thermal_protection:windows
- first oil crisis. There is a layer of insulating air between the two panes. * The thermal transmittance coefficient is reduced by the air layer to about **2.8 W/(m²K)**, which means that ... which has a lower heat conductivity than ordinary air. Thus this so called "heat protection glazing" or... emperatures (-15°C). However, there is still cold air descent ocurring at the window and uncomfortable
- Thermal insulation
- f the interior surfaces is nearly the same as the air temperature, irrespective of the type of heating ... indoor climate without any cold radiation or cold air pockets near the floor. - ...And if your bui... r surface temperature is also close to the indoor air temperature which means that it is lower than tha
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- the exterior plaster (blue square) * outdoor air (green curve). Each sensor measures the temperat... * Throughout the entire period of time outdoor air temperatures are well below the room temperature:... comfortable temperature close to that of the room air. Extremely little heat is lost through the wall a
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- pecially in the context of interior insulation an air ventilation unit helps to limit the indoor RH and... ]** DELPHIN: Simulation program for coupled heat, air, moisture, salt and VOC transport. Available at:
- Windows
- e heating near the windows to compensate for cold air drops, draughts and “cold radiation” caused by th
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- ilation heat loss which is based on the exchanged air volumes and the heat recovery system (see [[Plann
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- ection of the external envelope (U-value) and the air exchange are mainly responsible for the heating e