- Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
- art of the energy transition taken care of. After all, the low energy demand in a Passive House can sus... alance. * In a **Passive House Premium**, typically far more energy is produced than needed. It is t... ssive House Standard. This figure is the bases of all of the classes because it provides a starting poi... ria for comfort and hygiene are also the same for all three classes. But heating energy demand does n
- PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
- eist 2015].// ===== Introduction ===== The so-called PER concept (Primary Energy Renewable) were fir... urther developed, applied and analysed internationally. With an hourly resolution load profiles of the ... d solely from renewable energy sources, including all necessary storage facilities (Figure 1). The indi... final energy consumed at the building, including all losses incurred along the way. For example, a PER
- Addendum concerning the use of vacuum insulation
- w U-values can be reached, even with very narrow wall constructions. This seems to be especially attractive for developers in locations where floor space is... fit schemes where the available space for the installation of insulation is limited. On the other hand... rd, non-vacuum insulation materials cannot be installed or are not economical (under consideration of l
- The Passive House Classes: Classic, Plus and Premium
- They classify the building in terms of their overall efficiency level and the renewable energy generat... it standards remain unchanged and is the same for all three classes (relating to useful energy demand f... ergy supply. The higher the achieved level of overall efficiency and of renewable energy generation, th... Passive House Classes. Plus and Premium classes call for increased overall efficiency (figures on the
- Building Certification
- _benefits-of-certification.htm|advantages]]** for all parties involved. The focus is on planning, becau... bridge free design, high-quality windows and installation, ventilation system and other building servi... educational buildings). These are exclusively so-called "functional criteria", i.e. individual structur... technical details are not prescribed, but an overall coherent planning with a competently executed ene
- Certified Passive House Components
- ng engineering systems and not by living “economically”. Besides careful planning of details, this requ... larly energy-efficient components –which are generally about two to four times as efficient as the prod... nt specific values of the related products, especially with regard to their permanency. Relevant experi... PHI to base the requirement standard on the physically or physiologically verifiable impartial requirem
- Building Criteria: Overview of Changes
- through the quality assurance system set up in parallel. Through the course of time, these criteria ha... onventional methods may continue to be used optionally. ===Classic, Plus and Premium Classes === {{... or heating and cooling demand remain the same for all classes. ===Globally applicable === Based on extensive scientific preliminary analyses, the criteria
- Certification of terraced houses and semi-detached/duplex houses according to Passive House Institute criteria
- housing as a whole, whereby individual houses (usually the end-of-terrace houses) can have an energy de... ). With this method, the end-of-terrace houses usually require a better standard of thermal protection ... terraced house complies with the criteria individually or if the planning for individual terraced house... ifferent parties. **Method 1** is appropriate in all other cases. This reduces the expenditure for pla
- Certification of buildings in which the ground floor is used for commercial purposes (for PHPP 9, revised 5-Sep-2016)
- the entire heated volume of a building, including all floors and usage areas, is generally taken into account for certification. The anticipated types of us... , homogeneous utilisation of the upper floors (usually residential or office use), while the commercial... loors which are used for commercial purposes. For all variants it is assumed that the upper floors are
- Evaluation of server and server room efficiency for non-residential buildings that exceed the primary energy criterion
- e evaluation of servers and server rooms: As for all other Passive House components, basically the most energy-efficient and cost-effective server variant ... tiated information for this and lists the commercially available server models with their hardware; usi... own server using the listed hardware. For externally communicating simple and clearly defined criteri
- Certification of Passive House office buildings @certification:certified_passive_houses
- ed building must perform as a Passive House under all circumstances that can reasonably be assumed with... assumption. This is very significant for the overall performance, as heating the building with losses ... in summer:\\ \\ A higher occupancy level essentially leads to higher internal gains, which means that
- Sample Documents for Building Certification @certification:certified_passive_houses
- ewable energy generation systems that are not installed on the building site === Guidance, checklists ... n of a window profile and a {{:picopen:window_installation_thermal_bridge_calculation.pdf|window installation thermal bridge}} Guidance on the calculation