• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » all

all

Search

You can find the results of your search below.

Contains
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning:refurbishment_with_passive_house_components
  • Any namespace
  • planning:refurbishment_with_passive_house_components:thermal_envelope (4)
  • planning:refurbishment_with_passive_house_components:mechanical_systems (1)
  • planning:refurbishment_with_passive_house_components:ventilation (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • Overall retrofit plan for step-by-step retrofits to EnerPHit Standard

Fulltext results:

Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
47 Hits, Last modified: 6 years ago
ophit_logo.png|}}]] \\ \\ \\ \\ \\ ====== Overall retrofit plan for step-by-step retrofits to EnerP... ave been the focus of a consortium of 14 partners all across Europe. The share of step-by-step retrofit... efficient heating system, which could not be installed for now. In other multi-family buildings, only ... components:** For example, Step 1 consist of the wall insulation; in Step 2, the windows will be replac
Windows in a step-by-step retrofit
47 Hits, Last modified: 9 years ago
community can only reach a minimal consensus. Ideally, windows and façades should always be retrofitte... ulation ===== ==== 2.1 Starting point ==== Generally, new windows are installed in the position of the old ones. This approach lowers investment costs bec... ever, high follow-up costs. In the end, once the wall is insulated, it will have thermal bridges from i
Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
44 Hits, Last modified: 9 years ago
ld and inefficient facilities. This situation is called ‘energy poverty’ and affects many people i ===... es for Interventions in Existing Buildings, Especially in Social Housing ===== [{{:picopen:treviana_fac... fly. Moreover, these retrofits are performed by small companies where no qualified technicians are invo... priate and the execution quality is deficient. Usually, no quality control is done at the end of the wo
Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
38 Hits, Last modified: 12 months ago
t or “blower door test”) which determines the overall remaining leakage of a building. A fan is installed into a door or window to create a negative pressur... l_features_in_modernisations#literature|[Darup et all 2005] ]]). With professional planning and implem... ement before the start of modernisation work (so-called initial or preliminary measurement), any proble
Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
30 Hits, Last modified: 6 years ago
ng to PHPP9 was 105kWh/(m².a). The cast concrete wall (already insulated internally by 10cm of mineral wool) has been externally insulated with 20cm of expanded polystyrene (lambda 0.036W/m.K), then fixed to the wall with mortar glue and thermal bridge free dowels,
Refurbishment with Passive House components - introduction
30 Hits, Last modified: 7 years ago
nisation of existing building stock was systematically investigated in the 24th session of the Research... ent_-_introduction#Literature|[AKKP-32] ]]. The challenges of carrying out individual renovation measur... ng buildings using Passive House components is finally ready for implementation on a large scale. Since... ith Passive House level insulation is econo-\\ mically ideal under the present and future conditions.\\
Component Award 2016: Affordable ventilation solutions for retrofits
24 Hits, Last modified: 6 years ago
peration but also the initial work needed for installation. Comfort ventilation systems with heat recov... from supply air rooms into extract air rooms via hallways, but also, for instance, from bedrooms into l... istribution (Figure 1). This new concept is especially useful for retrofits because the duct network ca... dea is that supply air enters only one room (the hallway or living room, for instance). Small ventilato
Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
24 Hits, Last modified: 5 years ago
ct is to show the positive synergy effects of installing building integrated solar at the same time as ... s that the existing concrete façade will be externally insulated and covered with thin film solar modules and more effective crystalline solar modules will be installed on the roof. New Passive House-certified doors and windows will als
Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
19 Hits, Last modified: 6 years ago
extent that the thermal bridge addition becomes smaller or equal to zero with regard to the external su... uninterrupted layer of thermal insulation applied all around the envelope is represented schematically. One glance is enough to identify the potentially significant thermal bridges: * Masonry projecting
Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
16 Hits, Last modified: 6 years ago
r.com // \\ \\ The Passivhaus standard was initially developed in Germany for mid and northern Europe... ct is improving the energy-efficiency and RES installation of step-by-step retrofitting to contribute t... ope such as skylights, façades, windows, curtain walls, roofs, balcony railings and floors. These multi... at offers the best result in terms of kWh/kWp installed under these irradiation conditions. The a-Si te
Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
9 Hits, Last modified: 7 years ago
om energy losses through an uninsulated exterior wall over a 20-year period. The other four columns give the overall costs (i.e. additional investment plus energy costs) for an insulated exterior wall, each based on different levels of insulation (co... less significant, as additional costs are practically limited to the additional insulation material [K
Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
8 Hits, Last modified: 8 years ago
by a new floor with 300mm FOAMGLAS® insulation in all rooms. As in many places in Sweden, the ground be... fitted, despite FOAMGLAS® board (if properly installed) already having radon barrier properties. This shield, plus the later installation of a MVHR system, will ensure that there is ... radioactive gas in the house. One of the main challenges when fitting a new ground floor to an existi
Prospects for the modernisation of existing buildings using highly efficient components
5 Hits, Last modified: 7 years ago
or the modernisation of existing buildings. Originally, these components were developed for use in new ... Achieving the Passive House limit (heating load smaller than 10W/m²) in new constructions therefore jus... mples, in the case of existing buildings it is usually not possible to achieve the Passive House Standa... the apartments and commercial spaces involved usually have a functioning heat distribution system (usu
Passive House refurbishment - thermal envelope
2 Hits, Last modified: 7 years ago
:microsoft_word_-_01_fact-sheet_en_window-better-wall_kk.pdf|Is it problematic if the window is better than the wall? }}
Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
2 Hits, Last modified: 11 years ago
d daylight openings that can be altered only minimally. Retrofits can also have a negative impact on da... mpact on daylighting [We1 2012]. Beyond systematically analyzing daylighting, the goal is to develop a ... assive_house_conference_contributions_4|List]] of all released conference proceedings of the 17th Inter
Crosstalk silencers @planning:refurbishment_with_passive_house_components:ventilation
1 Hits, Last modified: 11 years ago

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN