• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » all

all

Search

You can find the results of your search below.

Ends with
  • Exact match
  • Starts with
  • Ends with
  • Contains
@certification
  • Any namespace
  • certification:passive_house_categories (2)
  • certification:certified_passive_houses (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Fulltext results:

PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
14 Hits, Last modified: 15 months ago
d solely from renewable energy sources, including all necessary storage facilities (Figure 1). The indi... final energy consumed at the building, including all losses incurred along the way. For example, a PER... ly be stored and used on a demand basis. In fact, all systems based on secondary energy (e.g. district ... he electrical load profile (end energy demand). All load profiles are smoothed ±4 hours in order to a
Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
10 Hits, Last modified: 15 months ago
art of the energy transition taken care of. After all, the low energy demand in a Passive House can sus... ssive House Standard. This figure is the bases of all of the classes because it provides a starting poi... ria for comfort and hygiene are also the same for all three classes. But heating energy demand does not tell the whole story; after all, heating energy demand is roughly equal to hot wa
The Passive House Classes: Classic, Plus and Premium
6 Hits, Last modified: 15 months ago
They classify the building in terms of their overall efficiency level and the renewable energy generat... it standards remain unchanged and is the same for all three classes (relating to useful energy demand f... ergy supply. The higher the achieved level of overall efficiency and of renewable energy generation, th... Passive House Classes. Plus and Premium classes call for increased overall efficiency (figures on the
Building Certification
5 Hits, Last modified: 14 months ago
_benefits-of-certification.htm|advantages]]** for all parties involved. The focus is on planning, becau... technical details are not prescribed, but an overall coherent planning with a competently executed ene... lightly higher energy demand, it offers virtually all the advantages of the Passive House Standard. Th... _certificaton_guide|Building Certification Guide (all languages)]] [[.:certified_passive_houses:exampl
Building Criteria: Overview of Changes
4 Hits, Last modified: 3 years ago
or heating and cooling demand remain the same for all classes. ===Globally applicable === Based on ex... ey can now be applied without any restrictions in all climates globally for all energy standards and building types (i.e. for Passive House, EnerPHit and Lo... difficult basic prerequisites such as extremely small detached houses in strongly shaded situations. An
Addendum concerning the use of vacuum insulation
3 Hits, Last modified: 3 years ago
w U-values can be reached, even with very narrow wall constructions. This seems to be especially attrac... e, unless it can be demonstrated that this would fall under national operation and maintenance requirem... protection:external_walls:passive_house_suitable_wall_systems]] [[planning:thermal_protection:integrat
Certification of terraced houses and semi-detached/duplex houses according to Passive House Institute criteria
3 Hits, Last modified: 3 years ago
ifferent parties. **Method 1** is appropriate in all other cases. This reduces the expenditure for pla... is necessary. Despite this, the energy demand for all terraced houses in total is not higher than with ... and set out in written form at an early stage by all relevant stakeholders. It is possible to certif
Evaluation of server and server room efficiency for non-residential buildings that exceed the primary energy criterion
3 Hits, Last modified: 18 months ago
e evaluation of servers and server rooms: As for all other Passive House components, basically the mos... onsumption measurements should be carried out for all servers in idle mode as well as in operation mode... the effectiveness of the measures and so that a small database with "empirical values" can be created f
Certification of buildings in which the ground floor is used for commercial purposes (for PHPP 9, revised 5-Sep-2016)
2 Hits, Last modified: 2 years ago
the entire heated volume of a building, including all floors and usage areas, is generally taken into a... loors which are used for commercial purposes. For all variants it is assumed that the upper floors are
Certification of Passive House office buildings @certification:certified_passive_houses
2 Hits, Last modified: 6 years ago
ed building must perform as a Passive House under all circumstances that can reasonably be assumed with... assumption. This is very significant for the overall performance, as heating the building with losses
Certified Passive House Components
1 Hits, Last modified: 2 years ago
e also been specified for defined climate zones. All criteria can be expressed by using measurable qua

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN