• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » all

all

Search

You can find the results of your search below.

Ends with
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning:refurbishment_with_passive_house_components
  • Any namespace
  • planning:refurbishment_with_passive_house_components:thermal_envelope (4)
  • planning:refurbishment_with_passive_house_components:mechanical_systems (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • Overall retrofit plan for step-by-step retrofits to EnerPHit Standard

Fulltext results:

Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
17 Hits, Last modified: 12 months ago
t or “blower door test”) which determines the overall remaining leakage of a building. A fan is install... l_features_in_modernisations#literature|[Darup et all 2005] ]]). With professional planning and implem... plied by the clear room height. The volume in a wall that results from the installation of a window or... 29] ]]. The envelope surface is the total area of all floors, walls and ceilings that enclose the volum
Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
16 Hits, Last modified: 9 years ago
fly. Moreover, these retrofits are performed by small companies where no qualified technicians are invo... , usually in the first winter season, because not all relevant factors had been considered in the plann... As the owner cannot afford to undertake the works all at once, the refurbishment will be performed step... ructure, insulation and airtightness • Exterior wall insulation and thermal bridges improving • Passi
Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
14 Hits, Last modified: 6 years ago
ophit_logo.png|}}]] \\ \\ \\ \\ \\ ====== Overall retrofit plan for step-by-step retrofits to EnerP... ave been the focus of a consortium of 14 partners all across Europe. The share of step-by-step retrofit... components:** For example, Step 1 consist of the wall insulation; in Step 2, the windows will be replac... ed for will actually be achieved after completing all steps. The pre-certification can take place as so
Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
12 Hits, Last modified: 6 years ago
ng to PHPP9 was 105kWh/(m².a). The cast concrete wall (already insulated internally by 10cm of mineral ... lystyrene (lambda 0.036W/m.K), then fixed to the wall with mortar glue and thermal bridge free dowels, ... nstalled flush on the outer face of the concrete wall and equipped with movable shutters. Existing shut... ernal walls to tape the membrane to the concrete wall. The house was equipped with a mechanical supply-
Windows in a step-by-step retrofit
12 Hits, Last modified: 9 years ago
ever, high follow-up costs. In the end, once the wall is insulated, it will have thermal bridges from i... aises costs further; the application of exterior wall insulation and lower exterior aperture sizes due ... ‘embrasure’ effect, especially when windows are small. ==== 2.2 Proposed solution ==== For the EuroPH... dow frame can easily have insulation added to it. All other solutions turned out to be detrimental: If
Refurbishment with Passive House components - introduction
10 Hits, Last modified: 6 years ago
newed anyway, then scaffolding will be put up and all remaining measures will be carried out in any cas... ualitatively better implementation will be very small.\\ \\ | {{:picopen:daemmung_altbau.jpg}} |//Retro... nts is not only economical but also preferable in all aspects. The economic situation is even better f... he building owner and residents also benefit from all the other advantages, which have already been exp
Component Award 2016: Affordable ventilation solutions for retrofits
9 Hits, Last modified: 6 years ago
oom (the hallway or living room, for instance). Small ventilators in the lintels of interior doors or i... the building. It may also be interesting to install decentral dwelling ventilation systems in space t... ance of the ventilation unit (once a year in the fall before the heating season begins is recommended, ... the reason for the improvements, especially for small ventilators. The duct networks must have low pres
Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
7 Hits, Last modified: 6 years ago
uninterrupted layer of thermal insulation applied all around the envelope is represented schematically.... sonry projecting out of the envelope at the knee wall * Wood beam ceilings as intermediate ceilings;... the two standard components shown in Fig. 2. The wall with its “one-and-a-half bricks“ masonry is typic... tically perforated brickwork” stands for slender wall constructions of the 50s and 60s, and also for th
Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
6 Hits, Last modified: 6 years ago
ed surface temperatures and ambient temperatures. All external meteorological parameters were also logg... d under Madrid (Spain) climate condition: a base wall BW (plaster + concrete blocks + cement mortar) and a photovoltaic ventilated facade PVF (base wall + thermal insulation+ air chamber+ opaque a-Si ph... situation, the inner and outer temperatures of a wall would remain constant. This thermal transmittance
Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
6 Hits, Last modified: 5 years ago
ildings (similar to many masonry structures built all over Europe in the mid-late 1900’s) are now in gr... sts for renovating other similar buildings could fall to the level that no subventions would be needed ... e entire cost of the photovoltaic system and the wall assembly (i.e. inverters, cables, insulation) and... e investment is around 200 €/m². For a plastered wall, the investment cost is approximately 100 €/m² (m
Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
6 Hits, Last modified: 7 years ago
om energy losses through an uninsulated exterior wall over a 20-year period. The other four columns give the overall costs (i.e. additional investment plus energy costs) for an insulated exterior wall, each based on different levels of insulation (co... ldings components. If, for example, the exterior wall is to be renovated first, the existing roof overh
Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
5 Hits, Last modified: 8 years ago
by a new floor with 300mm FOAMGLAS® insulation in all rooms. As in many places in Sweden, the ground be... oards with draining properties are fitted to the wall. The resulting Ψ–value of the wall/floor connection for the PHPP input is approximately 0.020-0.040W/(... rner where the concrete foundation stops and the wall begins, since this is the exact point where the f
Passive House refurbishment - thermal envelope
2 Hits, Last modified: 7 years ago
:microsoft_word_-_01_fact-sheet_en_window-better-wall_kk.pdf|Is it problematic if the window is better than the wall? }}
Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
1 Hits, Last modified: 11 years ago
assive_house_conference_contributions_4|List]] of all released conference proceedings of the 17th Inter

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN