Fulltext results:
- Types of ventilation @planning:building_services:ventilation:basics
- n - but it turns out that there is no conflict at all, if efficient components are used. ===== Ventila... gh leaks is not adequate in the heating period at all (see also [[Planning:Airtight construction]]): \\... ouse Institute shares this opinion, that first of all, air pollution should be limited at the source if... on concept is of utmost importance today, even if all efforts are being made to keep indoor air polluti
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- \ ==== ...do I need to keep the windows closed at all times? ==== \\ **Wrong** – Absolutely not! There ... turn and tilt fitting. At least this is true for all places on the planet, there external conditions a... ent type of ventilation system would be needed to allow for significantly higher air change rates. Such... se problems, even when bedroom windows are tilted all night long during winter. In this case, the only
- Air volumes @planning:building_services:ventilation:basics
- witch.png?250}}\\ In principle, it makes sense to allow occupants to control the air volumes according ... to problems for lower air volumes! ==== First of all, the linear characteristics of the ducting networ... ctions and the loss of pressure including that of all installations. * Based on these linear characte... ause due to the good level of thermal protection, all interior surfaces of external components are so w
- Compact HVAC systems
- mpact heat pump systems' are the best choice that allow heating, as well as cooling and dehumidificatio... water tank and a more sophisticted controller and all parts to be well combined. The basic technology c... Passive Houses: The low heating and cooling loads allow a wide variety of effient heating and cooling s
- Ventilation
- moved constantly from the kitchen, bathrooms, and all other rooms with air pollution. Fresh air has to ... , over 90 percent of the heat can be transferred, allowing the supply air to come in at nearly room tem... components/| certified ventilation units ]]to see all the high-efficient components. Additional articl
- Differentiation between Vv and Vn50 values @planning:building_services:ventilation
- ess of the actual height. | Exact caltulation: \\ All rooms of the building (including the stairs + ele... For non-residential buildings, the mean value of all room heights should be entered here. The air vo
- The ventilation system – there is no alternative @planning:building_services:ventilation
- e requirements for a healthy indoor climate while allowing for significant energy savings; and once thi... sensible and economical option will be to fulfil all the remaining Passive House criteria and build a
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
- g:building_services:heating_and_dhw|Overview]] of all articles on Passipedia about "Heating and DHW" [... assive_house_conference_contributions_4|List]] of all released conference proceedings of the 18th Inter
- Heating and DHW
- ion units were studied. The treated floor area of all projects totals 25,440m². Nine of the projects ar
- Supplying Passive Houses with sustainable energy @planning:building_services:heating_and_dhw
- this example village would only be sustainable if all buildings could be heated with the available wood
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- ures and the efficiency of the passive systems** All other systems are assumed to provide the same hea