Fulltext results:
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- ave been the focus of a consortium of 14 partners all across Europe. The share of step-by-step retrofit... ed for will actually be achieved after completing all steps. The pre-certification can take place as so... owing prerequisites have been met: • The ERP and all other necessary documents in accordance with buil... ptimal final result can securely be obtained over all steps with manageable effort. The ERP output file
- Energy balances - Background @planning:calculating_energy_efficiency
- d or cooled space" or more precisely: it includes all areas in a building in which comfortable thermal ... ould prevail. It is usually convenient to include all "passively heated" areas in the balance, if the b... (stationary) U-values be used in calculations at all? Isn't the heat storage more important than the ... ndicated which reference area they are based on. All other values should be treated with caution – and
- Thermal insulation @planning:thermal_protection
- well insulated. The building envelope consists of all the building elements which separate the inside f... -> Good thermal protection can be achieved for **all construction methods** and has already been succe... rmwork element technology, steel construction and all types of mixed constructions. -> An appropria... limate). These values are not only benchmarks for all construction methods but also the [[planning:ther
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- considerably reduce the amount of energy used by all healthcare applications while maintaining at leas... e first step in studying hospitals is to identify all energy consumers and determine what the usual con... Figure 2: \\ Example of energy demand values from all energy applications in a hospital \\ (EnEV: refer... ]].//|\\ \\ In terms of primary energy demand for all applications in a hospital providing maximum care
- Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
- ly insulated building envelopes have to be cooled all throughout the year. Increasingly longer opening ... he primacy of economy will have to be accepted in all cases: turnover is all-important; attempts to reduce the energy demand of retail stores do not have to be economically viable by themselves; above all, they must be compatible with the sales concept.
- Types of ventilation @planning:building_services:ventilation:basics
- n - but it turns out that there is no conflict at all, if efficient components are used. ===== Ventila... gh leaks is not adequate in the heating period at all (see also [[Planning:Airtight construction]]): \\... ouse Institute shares this opinion, that first of all, air pollution should be limited at the source if... on concept is of utmost importance today, even if all efforts are being made to keep indoor air polluti
- Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
- The entire building defines the system boundary. All energy fluxes are part of the model, including all electric appliances. This makes it possible to simu... the whole building approach is the integration of all system components including the consideration of ... l problem "building & heating" in the coupling of all appropriate physical theories ("first principles"
- Outdoor thermography @planning:thermal_protection:thermal_protection_works
- de independent evidence that insulating buildings allows for considerable energy savings and increases ... rared|infrared radiation (from Wikipedia)]] (IR). All objects surrounding us emit thermal radiation wit... ation with a wavelength between 8 and 15 µm which allows for conclusions to be drawn regarding the obje... ound floor\\ window. The scaffolding and the bags allow a good view of\\ the wall and will serve as poi
- Thermal protection and modernisation of existing buildings @planning:planning
- mplemented measures prove to be adequate. This is all the more important because subsequent "correction... resent, EnerPHit certification can be achieved if all energy related building components have been mode... es of the KfW-Bank show that approximately 2/3 of all funded projects consisted of single or multiple r... th a section of the building only, then including all or at least most components, the efficiency of a
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- , usually in the first winter season, because not all relevant factors had been considered in the plann... ple has been addressed from a different approach, allowing us to explore three scenarios: detached hous... As the owner cannot afford to undertake the works all at once, the refurbishment will be performed step... and cooling demands as far as possible but above all to increase the surface temperature, raise the co
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- the second path to go - and that will also reduce all the other indoor air pullutants to secure levels ... nt in this case that the humidifier is kept clean all the time. \\ In comparison with residential bui... substances e.g. Radon. With a ventilation system, all pollution is reduced to a hygienically satisfacto... note that "it doesn't smell like a school here at all").}}] As shown by experience, it should be ensur
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- of external walls is pointless or even damaging. Allegedly, the effects of the thermal storage capacit... rom solar radiation are insufficiently, or not at all, taken into account by scientists. The author o... eantime, many new findings have become available, all of which support this publication. The full (Germ... edge in the rank of "absolute truth", but it does allow the best possible description of the facts poss
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- cooking, dishes are washed and food is kept cool, all of which requires a lot of energy; in addition, e... nergy, generally reduces internal loads, and thus allows smaller ventilation units to be used. The topic is especially timely as Germany switches to all-day schools with school cafeterias. \\ \\ ===== ... ich 2013]]]. The technologies already available allow energy demand to be reduced by up to 70 % for a
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- newed anyway, then scaffolding will be put up and all remaining measures will be carried out in any cas... nts is not only economical but also preferable in all aspects. The economic situation is even better f... he building owner and residents also benefit from all the other advantages, which have already been exp... tion. An exhaust air outlet should be planned for all rooms with high levels of humidity. Constantly ex
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- l):\\ \\ ===== Very low heat flows ===== Since all three temperature curves are very close together ... been – using this precise calculation method for all scientific analyses. The calculated results ba... eat flowing from the wall to the exterior – after all, this is where the insulation layer does an excel... and just before 6am, the temperature decreases in all brick layers of the wall: The wall gives off heat
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
- The overall heat transfer coefficient or U-value @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems