Fulltext results:
- Energy balances - Background
- d or cooled space" or more precisely: it includes all areas in a building in which comfortable thermal ... ould prevail. It is usually convenient to include all "passively heated" areas in the balance, if the b... (stationary) U-values be used in calculations at all? Isn't the heat storage more important than the ... ndicated which reference area they are based on. All other values should be treated with caution – and
- Dynamic simulation of a building's thermal performance
- The entire building defines the system boundary. All energy fluxes are part of the model, including all electric appliances. This makes it possible to simu... the whole building approach is the integration of all system components including the consideration of ... l problem "building & heating" in the coupling of all appropriate physical theories ("first principles"
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- easured results; - incidentally this was true for all building standards. \\ \\ |{{ :picopen: comp_PHPP... different users]]: This is actually the case for all energy standards and not specific for energy effi... ch the results of dynamic simulations [AkkP 13]. All simulation models that were used had been previou... PHPP results fell within the acceptance range in all cases. For sensible cooling, PHPP was within the
- The overall heat transfer coefficient or U-value @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- U-value ====== In the PHPP worksheet U-Values of all building elements of the building envelope, or, in other words, all building elements through which heat is lost, are... 108-4. For the certification of Passive Houses in all other countries, the lambda value determined as d
- PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- values for both sensible and latent cooling under all considered boundary conditions. The algorithm mod... assive_house_conference_contributions_4|List]] of all released conference proceedings of the 17th Inter
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- possible to visually verify in the 3D model that all the heat-loss surfaces have been correctly taken ... assive_house_conference_contributions_4|List]] of all released conference proceedings of the 17th Inter
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- The PHI points out that it is not permissible at all to use such high values for the planning of Passi... ill correct requires more closer examination (Are all the usual household appliances present and are th
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- _the_passive_house_planning_package|Overview]] of all articles on Passipedia about PHPP [[phi_publica... assive_house_conference_contributions_4|List]] of all released conference proceedings of the 18th Inter
- PHPP – Passive House Planning Package
- for different climatic regions around the world. All calculations in the PHPP are based strictly on th
- Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- recommend ignoring the buffer zones and entering all envelope areas as adjacent to ambient. * If a