Fulltext results:
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- recovered from air lost through building joints (also known as uncontrolled ventilation). In particula... h<sup>-1</sup> ; however, much higher values are also acheived. Energy efficient buildings should reach... 2000] ]]). Such excellent airtightness levels can also be achieved for modernised buildings if airtightn... rature|[EN 13829] ]] standard, the measurement is also valid if a pressure difference of at least 25 Pa
- Refurbishment with Passive House components - introduction
- e insulation would be a waste of money. It should also be considered that it would be practically imposs... ulation, thereby reducing the risk of damp walls, also at areas with outside connections. Constructions ... ly in relation to windows. * Summer comfort is also improved due to insulation of the heat-accumulati... me (e.g. through night-time ventilation). This is also applicable to improved windows. * If at some l
- Component Award 2016: Affordable ventilation solutions for retrofits
- uce not only pressure losses during operation but also the initial work needed for installation. Comfort... ir rooms into extract air rooms via hallways, but also, for instance, from bedrooms into living rooms an... or engineering room within the building. It may also be interesting to install decentral dwelling vent... in the past few years. Brushless electric motors (also called EC motors for “electronically commutated”
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- even\\ in old buildings?**//|\\ Can this approach also be applied in the case of modernisations of old b... lender wall constructions of the 50s and 60s, and also for those in the 70s as other materials were also used (e.g. pumice), but the results are similar, and ... d for the basement ceiling, later on increasingly also for other floors except for the topmost ceiling.
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
- ew Passive House-certified doors and windows will also be installed and demand controlled ventilation co... d temperature / humidity from each apartment will also be installed. The project is led by members of K... han the lower cost per square meter) is that they also perform well under shading and in diffuse light. ... cally up the façade and rest on L shaped fittings also screwed into the furring. Using point fasteners t
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
- ures. All external meteorological parameters were also logged. Basically, the test cell is an accurate c... ly does it produce free clean energy on site, but also natural illumination is provided. Furthermore, th... triple glazing photovoltaic insulating units can also be incorporated into the project providing improv
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
- ilation concepts, heating or cooling systems, can also be adapted using pre-defined entries. • Other pa... ill be replaced later) (Figure 6). • There might also be retrofits of sections of a building, even sing... able (PER) chart in PHPP 9}}] You can, of course, also indicate if renewable energy sources are to be in
- Windows in a step-by-step retrofit
- site window solution presented in Section 2.3 can also be used here. ==== 3.4 Replacing glazing ==== I... , however, is much more expensive than argon, and also the losses at the glass edges are much lower if t... life. When the glass is renewed, old sealants can also be replaced if necessary. [{{:picopen:fig_6_win.
- Prospects for the modernisation of existing buildings using highly efficient components
- th a high degree of utilisation. Such an approach also requires significant improvement of the building ... ve Houses [AkkP 24], Passive House components are also suitable for the modernisation of existing buildi
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- und beneath this family dwelling is pure rock and also has high levels of radon gas emissions. An additi... e this is the exact point where the floor surface also meets the wall. The concrete foundation is still
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
- Available: http://www.passibat.fr/. | ==== See also ==== [[planning:refurbishment_with_passive_house
- Passive House refurbishment - thermal envelope
- ofits - windows first, then insulation }} (read also in {{ :picopen:07_fachinfo_fenster_schritt_fuer_s