Fulltext results:
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- === Airtightness – how and why? ===== There are many disadvantages of air flowing in through joints an... is why airtightness standards have been set for many years and why we still have them in current regul... k (so-called initial or preliminary measurement), any problematic areas where airtightness may be inade... evel of airtightness is expected for a building (many leaks) or if the building is particularly large,
- Refurbishment with Passive House components - introduction
- ter completion of the Tevesstraße (Frankfurt, Germany) and Hoheloogstraße (Ludwigshafen, Germany) projects, comprehensive metrological examinations were car... weather etc. (this would not be profitable under any circumstances). That is why, from the very beginn... for the relevant building component to be renewed anyway, then scaffolding will be put up and all remai
- Windows in a step-by-step retrofit
- rmal bridges and optimise solar gains. There are many reasons why retrofits are done step by step. Ofte... pe that it cannot wait. If a façade is renovated, any windows renewed “in the meantime” will still be i... h lowers investment costs because windowsills and any shading fixtures used do not need to be changed; ... r less cold outdoor air, insulation does not have any advantages. It is therefore recommended that th
- Component Award 2016: Affordable ventilation solutions for retrofits
- === Seventy percent of the building stock in Germany was constructed before 1989. Solutions that are e... unit, components, duct network, installation and any other costs, such as an encasement or suspended c... t their stands. ===== 6. Acknowledgments ===== Many thanks go to the members of the jury: André Zaman... nal Passive House Conference 2015 in Leipzig, Germany, Passive House Institute, Darmstadt.| | [Beuth Ve
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
- nstitute Rheinstrasse 44/46, 64283 Darmstadt, Germany Phone: +49 (0) 6151 826990, jan.steiger@passiv.de... ban Affairs and Spatial Development (BBSR) in Germany in 2014, 85 % of the costs for retrofits of resid... ts for the measures here, including the costs for anyhow-measures and financial support. \\ \\ \\ Effi... I nor the European Commission are responsible for any use that may be made of the information contained
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
- ces of electricity and CO2 in France (FR) and Germany (DE).}}] The Comparison worksheet in PHPP 9 enabl... investment costs. Costs that would have occurred anyway have been considered for the existing building... I nor the European Commission are responsible for any use that may be made of the information contained
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
- ause the ‘million program’ buildings (similar to many masonry structures built all over Europe in the m... onsidered a façade material (that would be needed anyway when applying external insulation). Maintenanc... I nor the European Commission are responsible for any use that may be made of the information contained
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
- assivhaus standard was initially developed in Germany for mid and northern European climates but has sp... I nor the European Commission are responsible for any use that may be made of the information contained
- Prospects for the modernisation of existing buildings using highly efficient components
- based on hot water pump heating) and there isn’t any reason why the existing system cannot continue to... , the existing heating surfaces are over-sized in any case as a rule, and if the heating demand is furt
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
- situation is called ‘energy poverty’ and affects many people i ===== 2 Issues for Interventions in Exi... I nor the European Commission are responsible for any use that may be made of the information contained
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- h 300mm FOAMGLAS® insulation in all rooms. As in many places in Sweden, the ground beneath this family ... I nor the European Commission are responsible for any use that may be made of the information contained
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
- pact on daylighting. Optimized lighting has very many positive features that should be considered when ... ngs less self-sufficient in terms of daylighting. Any such losses can be avoided or offset by taking th
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- ishment with Faktor 10, final report of the accompanying scientific research, published by Schulze Daru
- Crosstalk silencers @planning:refurbishment_with_passive_house_components:ventilation
- ions only have a slightly damping effect: without any preventive measures, a supply air network would f