Fulltext results:
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- sed by leaks in the building envelope. Sound insulation is reduced, drafts cause discomfort for occupants and there are high heat losses. That is why airtightness standards have been set for many years and why we still have them in current regulations. It is still widely beleived that poor airti
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
- lligent Energy –Europe (IEE) programme, deep renovations carried out step by step have been the focus ... ute for Research on Building, Urban Affairs and Spatial Development (BBSR) in Germany in 2014, 85 % of... uroPHit consortium thereby has developed recommendations, products, tools and quality assurance proces... mprove step-by-step retrofit processes and facilitate deep energy retrofitting even for single measure
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
- = Nuria Díaz Antón, Anne Vogt, Mercedes Sánchez Mateos, VAND arquitectura c/Villablanca, 85, oficina ... nfo ===== 1 Refurbishment in Spain – Current Situation ===== Refurbishment projects were not taken ... nto account by the Spanish energy efficiency regulation Código Técnico Español, CTE) until 2013, when the CTE was updated, and till now comfort and efficiency are not me
- Component Award 2016: Affordable ventilation solutions for retrofits
- \\ ====== Component Award 2016: Affordable ventilation solutions for retrofits ====== Author: Kristi... dability: the key to widespread residential ventilation with heat recovery ===== Seventy percent of the building stock in Germany was constructed before 1989. Solutions that are easy to integrate in such buildings will be c
- Windows in a step-by-step retrofit
- ctice, windows and façades are seldom retrofitted at the same time, even though doing so would save co... n tenants, or a window may be in such bad shape that it cannot wait. If a façade is renovated, any windows renewed “in the meantime” will still be in good... re simply is not enough capital to do both things at once. Sometimes, the ownership community can only
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
- architecture Le Rouget}}] **1. Envelope and Ventilation** \\ This 320m² house was built in the late 70’s near Lyon. The heating demand of the existing site according to PHPP9 was 105kWh/(m².a). The cast concrete wall (already insulated internally by 10cm of mineral wool) has been ex
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
- === Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house ======... (Gothenburg), which has long been run as a cooperative, will demonstrate a cost effective step-by-step deep retrofit with building integrated solar photovoltaics (BIPV) on the façade and ro
- Refurbishment with Passive House components - introduction
- roduction ====== The possibilities for the application of Passive House components in the modernisation of existing building stock was systematically investigated in the 24th session of the Research Group for Cost-effective Passive Houses [[pla
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
- go.png|}}]] \\ \\ \\ \\ \\ ====== Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitti... oped in Germany for mid and northern European climates but has spread around the world. It has been proved to work extremely well in Mediterranean climates and not only in residential buildings. Moreover, EnerPHit certification recognises refurbishment projects under Passiv
- Prospects for the modernisation of existing buildings using highly efficient components
- ====== Prospects for the modernisation of existing buildings using highly efficient components ====== ... ntribution to the 24th Session of the [[phi_publications:research_group_for_cost-effective_passive_hou... assive_house_components:prospects_for_the_modernisation_of_existing_buildings_using_highly_efficient_components#Literature|[Feist 2003] ]] focuses on the use of highly e
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- ign – i.e. optimising the details to the extent that the thermal bridge addition becomes smaller or eq... idges and airtightness in existing buildings#Literature|[AkkP 16] ]] ; [[planning:refurbishment_with_p... idges and airtightness in existing buildings#Literature|[AkkP 21] ]]). The advantages are obvious: the... with cold spots and moisture damage and no complicated and tedious calculations to make, just a few cl
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- ====== Insulation measures for the external envelope ====== Modernisation of the building envelope without insulation ("cosmetic refurbishment") is not efficient. The first... osts arising from energy losses through an uninsulated exterior wall over a 20-year period. The other
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- en ====== {{ :picopen:stages_of_floor_slab_renovation_1.png?700|}} Svartbäcksvägen 11 in Bagarmosse... e basement habitable. For this, the old, non-insulated concrete floor was dug out and replaced by a new floor with 300mm FOAMGLAS® insulation in all rooms. As in many places in Sweden, the ground beneath this family dwelling is pure rock and also has h
- Passive House refurbishment - thermal envelope
- :thermal_protection:thermal_protection_works:insulation_prevents_structural_damage_evidence_no.4_measu... th Passive House components:thermal envelope:Insulation measures for the external envelope]] {{:picop... members_only.png?25}} \\ \\ ===== Interior insulation ===== [[planning:refurbishment with Passive House components:thermal envelope:interior insulation|Interior insulation]] {{:picopen:members_only
- Passive House refurbishment - ventilation
- ====== Passive House refurbishment - ventilation ====== [[planning:refurbishment_with_passive_house_components:Ventilation:Crosstalk silencer]] [[planning:refurbishment_with_passive_house_components:Ventilation:Integrating ventilation ducts]] {{:picopen:members_only.png?25}} [[planning:building services:Ve