• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » at

at

Search

You can find the results of your search below.

Starts with
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning:thermal_protection:thermal_protection_works
  • Any namespace
  • planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • Outdoor thermography
  • Thermal protection in retrofits
  • Insulation works – Evidence no.1 "Measurements at a highly insulated wall"
  • Energy use for heating in a well insulated new building
  • Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems

Fulltext results:

Insulation works – Evidence no.1 "Measurements at a highly insulated wall"
30 Hits, Last modified: 3 years ago
== Insulation works – Evidence no.1 "Measurements at a highly insulated wall" ====== ===== Long-term measurements at exterior walls of highly insulated new buildings ... on _works.png?600 }}| |//** Temperatures measured at a highly insulated wall.\\ The entire section of the brick wall stays warm even at low outside temperatures\\ since it is protected
Outdoor thermography
12 Hits, Last modified: 3 years ago
application of the insulation:\\ The insulation at the exterior walls of the ground floor is nearly ... the facade with packages of\\ insulation panels attached to them (see regular picture).\\ \\ \\ **//... air temperature is approx. 6.46 °C ** as measured at the surface of the bags hanging from the scaffold... heat losses are caused by thermal bridges – e.g. at the edge of the window where the heat only travel
Thermal protection in retrofits
7 Hits, Last modified: 11 years ago
rt_eng.png?450 }}| |//** Old building - situation at the facade without insulation **//|//**Refurbishe... n the corner the temperatures can drop below 5°C. At these low temperatures the air contains very litt... ate additional insulation raises the temperatures at all critical connection points so far that the re... dernisation measures, but this is not appropriate at all. Especially the external walls must be well-
Insulation vs. thermal mass
6 Hits, Last modified: 3 years ago
s from solar radiation are insufficiently, or not at all, taken into account by scientists. The auth... the heating in a Passive House breaks down? Even at minus temperatures, such an insulated house cools... to be stored up as the amount which is available at the end again, if the temperatures at the beginning and end are the same.\\ \\ -> How long are "long
Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
6 Hits, Last modified: 6 years ago
ecially in these cases the decreased temperatures at the beam heads outside the insulation plane can c... ion systems, temperatures and relative humidities at different positions within the construction were ... reproduced with a deviation of less than ~5 % RH at the end of the considered period. With some varia... ably by the ventilation unit not working properly at that time. After the change of the filter a steep
Energy use for heating in a well insulated new building
2 Hits, Last modified: 6 years ago
rks:insulation_works_-_evidence_no.1_measurements_at_a_highly_insulated_wall| measurements at a highly insulated wall]]and it is based on the energy consu

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN