- Insulation works – Evidence no.1 "Measurements at a highly insulated wall"
- == Insulation works – Evidence no.1 "Measurements at a highly insulated wall" ====== ===== Long-term measurements at exterior walls of highly insulated new buildings ... on _works.png?600 }}| |//** Temperatures measured at a highly insulated wall.\\ The entire section of the brick wall stays warm even at low outside temperatures\\ since it is protected
- Outdoor thermography
- application of the insulation:\\ The insulation at the exterior walls of the ground floor is nearly ... air temperature is approx. 6.46 °C ** as measured at the surface of the bags hanging from the scaffold... heat losses are caused by thermal bridges – e.g. at the edge of the window where the heat only travel... he heat losses through the wall: those occurring at the insulated wall are reduced by a factor of 8 c
- Thermal protection in retrofits
- rt_eng.png?450 }}| |//** Old building - situation at the facade without insulation **//|//**Refurbishe... n the corner the temperatures can drop below 5°C. At these low temperatures the air contains very litt... ate additional insulation raises the temperatures at all critical connection points so far that the re... dernisation measures, but this is not appropriate at all. Especially the external walls must be well-
- Insulation vs. thermal mass
- s from solar radiation are insufficiently, or not at all, taken into account by scientists. The auth... the heating in a Passive House breaks down? Even at minus temperatures, such an insulated house cools... to be stored up as the amount which is available at the end again, if the temperatures at the beginning and end are the same.\\ \\ -> How long are "long
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- ecially in these cases the decreased temperatures at the beam heads outside the insulation plane can c... ion systems, temperatures and relative humidities at different positions within the construction were ... reproduced with a deviation of less than ~5 % RH at the end of the considered period. With some varia... ably by the ventilation unit not working properly at that time. After the change of the filter a steep
- Energy use for heating in a well insulated new building
- rks:insulation_works_-_evidence_no.1_measurements_at_a_highly_insulated_wall| measurements at a highly insulated wall]]and it is based on the energy consu