Fulltext results:
- Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
- emium: The Passive House classes and how they can be reached ====== // This article is an based on th... m: The new Passive House classes and how they can be reached" presented at the 19th International Pass... ous: building owners and designers who want to go beyond what economic and ecological considerations a... d. This figure is the bases of all of the classes because it provides a starting point by limiting the
- Certification of buildings in which the ground floor is used for commercial purposes (for PHPP 9, revised 5-Sep-2016)
- es (for PHPP 9, revised 5-Sep-2016) ====== **The below provisions are an older version which is appli... version 10 of the Criteria for Buildings may also be applied to projects using PHPP 9. ** ---- For t... hile the commercial areas on the ground floor may be utilised in widely differing ways depending on th... pper floors (without the ground floor). This will be stated on the certificate. b) The upper floors o
- PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
- actors is based on the ideas that have previously been published in [Feist 2013] and [Feist 2014] (see... tors describe how much more renewable energy must be supplied in order to cover the final energy consu... a surplus of 50% renewable primary energy has to be generated in order to be able to meet the final energy demand at the building. PER-factor = Δ(Ene
- Addendum concerning the use of vacuum insulation
- eir relative slimness means that low U-values can be reached, even with very narrow wall constructions. This seems to be especially attractive for developers in locations... floor space is very expensive and must therefore be maximized, and also for retrofit schemes where th... e Institute (PHI) recommends that this technology be used in a controlled manner, and only where stand
- Evaluation of server and server room efficiency for non-residential buildings that exceed the primary energy criterion
- t exceeds the primary energy requirements it must be demonstrated, that this exceedance occurs despite... fficient and cost-effective server variant should be chosen (taking into account the system requirements). Because the requirements for different server system... ergy consumption and high processing capacity can be just as efficient as a server with a low energy c
- Certified Passive House Components
- neering systems and not by living “economically”. Besides careful planning of details, this requires t... and clearly ascertainable criteria which need to be met by Passive-House-suitable products. These cri... . maximum radiation temperature difference of 5 K between the half spaces, derived from ISO7730). Wher... mulating the criteria, efficiency categories have been introduced (e.g. as for Passive House windows).
- Building Certification
- om/03_certification/02_certification_buildings/01_benefits-of-certification/01_benefits-of-certification.htm|advantages]]** for all parties involved. The focus is on planning, because only practice-oriented planning can be translated into a functioning building at the constructio
- Building Criteria: Overview of Changes
- ion square metres of Passive House floor area has been certified through the quality assurance system ... Through the course of time, these criteria have been carefully adapted and augmented several times i... solely through renewable sources. This system has been adopted into the criteria and replaces the prev... the new and conventional methods may continue to be used optionally. ===Classic, Plus and Premium
- Certification of Passive House office buildings @certification:certified_passive_houses
- ng internal gains of 3.5 W/m² (the reference area being the “treated floor area” of the PHPP, not the ... s standard values for certification are partly to be able to ensure consistency and also because the use of a building is often not permanent and not alwa... House under all circumstances that can reasonably be assumed within this time span. By planning the bu
- The Passive House Classes: Classic, Plus and Premium
- ches is to generate at least as much energy as is being consumed over the course of the year in absolu... uitive, this approach presents challenges and can be very misleading: * In a "net" energy balance, ... nergy needs to cover storage losses can, however, be quite significant (especially for heating demand,... zero-energy" approach, these losses would need to be taken into account. * It is easier to offset th
- EnerPHit – the Passive House Certificate for retrofits
- ents” Certificate. Significant energy savings of between 75 and 90 % can be achieved even in existing buildings, for which the following measures have proved to be particularly effective [Bastian 2022]: * impro... insulation (based on the principle: if it has to be done, do it right) * [[:planning:refurbishment_
- Certification of terraced houses and semi-detached/duplex houses according to Passive House Institute criteria
- terraced house may take place. Each homeowner may be given a copy of the certificate and the certifica... thod, the end-of-terrace houses usually require a better standard of thermal protection on account of ... re for planning, implementation and certification because the same standard of thermal protection (insulation thickness etc.) can be implemented and only one PHPP calculation is nece
- Criteria for buildings in other languages @certification:certified_passive_houses
- s ====== The official Criteria for Buildings can be downloaded from the Passive House Institute's web... e House organisations worldwide exist. These may be of use for your local promotion of the Passive Ho
- Sample Documents for Building Certification @certification:certified_passive_houses
- xamples of the most important documents that must be submitted for the building certification. === Sa