Fulltext results:
- Introduction: Retail stores as Passive Houses
- n moderately insulated building envelopes have to be cooled all throughout the year. Increasingly long... consumption. The primacy of economy will have to be accepted in all cases: turnover is all-important;... the energy demand of retail stores do not have to be economically viable by themselves; above all, they must be compatible with the sales concept. \\ [{{ :picop
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- hools:Passive House schools – requirements]] can be met with justifiable effort. These recommendations are not meant to be requirements – it is possible to deviate from them, but then compensating measures must generally be taken elsewhere. Calculations using the PHPP for ... gs. A/V ratios of less than 0.4 m²/m³ can usually be achieved if the buildings are well-planned, and n
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- w rates of the school's ventilation system should be based on health and educational objectives and no... lt also shows that the designed values should not be reduced even further. For increased air quantities attention would have to be paid to the resulting reduction in the relative a... y objectives of indoor air quality will certainly be achieved and the problem of low relative humidity
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- ingfor the State of Hesse. **The full study can be downloaded [[https://database.passivehouse.com/de... in_hospitals#references|[Destatis 2009]]] need to be renovated. To evaluate and tap the conservation p... concept, a few special aspects of hospitals must be taken into consideration, including areas with se... ance, such as operating rooms, the solutions must be adjusted accordingly. New concepts and approaches
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- on. \\ The main way that ventilation systems can be tweaked to improve operational efficiency is by o... nto the extent to which heat recovery systems can be used in hospital ventilation systems. Requirement... d for outdoor air, outdoor air exchange rates can be reduced considerably. \\ * Air exchange rates required for cooling demand should be determined based on the actual output data of med
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- a lot of internal heat and moisture, which has to be drawn out of the kitchen with sufficiently dimens... ads, and thus allows smaller ventilation units to be used. The topic is especially timely as Germany s... nologies already available allow energy demand to be reduced by up to 70 % for all energy applications... l. Optimization of each core process was found to be decisive. For instance, if dishwashing is energy-
- Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- cial kitchens in order to find out how energy can be saved without reducing indoor air quality. The fo... \ In general, the ventilation system also has to be optimally calibrated for kitchen usage and workfl... ces planners, kitchen planners, and users) has to be involved from the beginning of the planning phase
- Passive House schools
- men_pausenhalle_passivhausschule.jpg|//Can school be beautiful?// – impressions from the central recre... hat is important is the// know-how // - which can be obtained by every architect thanks to the book "P
- Passive House swimming pools @planning:non-residential_passive_house_buildings:swimming_pools
- for operational energy savings. These savings can be tapped by implementing various efficiency measure... ermany__** was one of two first pilot projects to be built based on the energy efficiency concepts dev