Fulltext results:
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- ir change rate necessary for good quality air can be ensured with mechanical ventilation. At the very... iscomfort and heat losses because the heat cannot be recovered from air lost through building joints (... air flowing through it Two similar terms should be clarified: the __wind__tightness of a building co... to increased energy consumption. This should not be confused with __air__tightness that is being disc
- Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
- measured in detail. A single room ("zone") will be modelled by DYNBIL as shown in fig. 1. In the me... heat gains. General assumptions on heat gains may be tolerable for energy inefficient buildings, but l... bil_multizonal.png|}}| |Fig. 2 Several zones will be connected to a building model with air flows betw... t conduction in solids and non-flowing fluids can be described by Fourier's dynamic heat conduction eq
- Windows in a step-by-step retrofit @planning:refurbishment_with_passive_house_components
- ndows are put in between tenants, or a window may be in such bad shape that it cannot wait. If a façad... any windows renewed “in the meantime” will still be in good shape and not need retrofitting. In addition, building users may not wish to be bothered further. Often, there simply is not enou... nsus. Ideally, windows and façades should always be retrofitted simultaneously whenever possible. Whe
- Airtightness measurements in Passive Houses @planning:airtight_construction
- ss measurements in Passive House buildings are to be carried out uniformly worldwide according to ISO ... of the reference volume for passive houses is to be carried out according to the procedure listed bel... part of the ISO 9972. The resulting volume is to be used for the determination of the n<sub>50</sub>-... \\ For the calculation and documentation, it can be helpful to use the "room data", which is included
- Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
- n moderately insulated building envelopes have to be cooled all throughout the year. Increasingly long... consumption. The primacy of economy will have to be accepted in all cases: turnover is all-important;... the energy demand of retail stores do not have to be economically viable by themselves; above all, they must be compatible with the sales concept. \\ [{{ :picop
- Thermal insulation @planning:thermal_protection
- ng demand the entire **building envelope** has to be well insulated. The building envelope consists of... ection comes in. -> Good thermal protection can be achieved for **all construction methods** and has... -> An appropriate level of insulation can also be applied to **existing buildings** at any given po... . A high level of insulation has always proven to be effective; to learn more please go to the followi
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- hools:Passive House schools – requirements]] can be met with justifiable effort. These recommendations are not meant to be requirements – it is possible to deviate from them, but then compensating measures must generally be taken elsewhere. Calculations using the PHPP for ... gs. A/V ratios of less than 0.4 m²/m³ can usually be achieved if the buildings are well-planned, and n
- Energy balances - Background @planning:calculating_energy_efficiency
- fic area. Consequently, energy balances can only be prepared for restricted spatial areas with clearl... is sinking. However, this is exactly what should be prevented in order to maintain living comfort. Therefore, the energy flowing out has to be replaced: another heat flow must travel from the... eplacement of this heat loss \\ and can therefore be reduced as required by more effective prevention
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- ll (German) version of the summary given here can be ordered from the following link: [[https://shop.p... ossible today. Furthermore, these statements can be checked by everyone, even regarding the topic of ... es absolute truth. One's own conviction can never be important enough to call into question the dignit... tally: by using statistical methods something can be said about the reliability with which energy can
- Thermal protection and modernisation of existing buildings @planning:planning
- the refurbishment so that the building owner can be sure that the stipulated optimal standard of ther... hieved and that the implemented measures prove to be adequate. This is all the more important because ... ermal protection measures almost always proves to be uneconomical. The EnerPHit standard requires eith... its ==== At present, EnerPHit certification can be achieved if all energy related building component
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- internal heat gains was devised below which will be used as a standard value for residential building... aken from the PHPP worksheet IHG. First it must be noted that the fluctuation range of occupancy and... verage values for the model shown here, which may be higher or lower in individual cases. Nevertheless... who inhabit this dwelling; temporary absence will be taken into account later on) can be calculated as
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- w rates of the school's ventilation system should be based on health and educational objectives and no... lt also shows that the designed values should not be reduced even further. For increased air quantities attention would have to be paid to the resulting reduction in the relative a... y objectives of indoor air quality will certainly be achieved and the problem of low relative humidity
- Don’t save on the insulation @planning:thermal_protection
- with in the following list. Taking no action will be much more expensive than carrying out insulation ... tter the level of insulation, the more money will be saved. The other features are also positively aff... e are the advantages of good insulation which can be enjoyed by the owner and occupant themselves.\\ \... it, do it right"** is the principle which should be applied to thermal protection. * No exterior
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- a more efficient heating system, which could not be installed for now. In other multi-family building... the wall insulation; in Step 2, the windows will be replaced and a ventilation system is installed; a... e retrofit of single sides of a building only can be envisaged (Figure 3). [{{:picopen:retrofitting_c... y that the standard being aimed for will actually be achieved after completing all steps. The pre-cert
- Types of ventilation @planning:building_services:ventilation:basics
- air quality is especially essential and can only be achieved if "used" air is regularly replaced by f... days, the heat losses\\ during strong winds will be intolerably high. Gap ventilation is\\ therefore ... ventilation is insufficient, the air quality will be poor and there will be a risk of condensation occurring. * If too much ventilation takes place, th
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Sound generation, sound dispersion and sound proofing in heat pumps @planning:building_services:heating_and_dhw:heating:heat_pumps
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
- Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems