• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » be

be

Search

You can find the results of your search below.

Exact match
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning
  • Any namespace
  • planning:refurbishment_with_passive_house_components (15)
  • planning:building_services (12)
  • planning:thermal_protection (12)
  • planning:calculating_energy_efficiency (9)
  • planning:non-residential_passive_house_buildings (9)
  • planning:airtight_construction (6)
  • planning:guides_and_aids (1)
  • planning:planning (1)
  • planning:summer_comfort (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • Differentiation between Vv and Vn50 values

Fulltext results:

Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
67 Hits, Last modified: 10 months ago
ir change rate necessary for good quality air can be ensured with mechanical ventilation. At the very... iscomfort and heat losses because the heat cannot be recovered from air lost through building joints (... air flowing through it Two similar terms should be clarified: the __wind__tightness of a building co... to increased energy consumption. This should not be confused with __air__tightness that is being disc
Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
44 Hits, Last modified: 5 years ago
measured in detail. A single room ("zone") will be modelled by DYNBIL as shown in fig. 1. In the me... heat gains. General assumptions on heat gains may be tolerable for energy inefficient buildings, but l... bil_multizonal.png|}}| |Fig. 2 Several zones will be connected to a building model with air flows betw... t conduction in solids and non-flowing fluids can be described by Fourier's dynamic heat conduction eq
Windows in a step-by-step retrofit @planning:refurbishment_with_passive_house_components
43 Hits, Last modified: 9 years ago
ndows are put in between tenants, or a window may be in such bad shape that it cannot wait. If a façad... any windows renewed “in the meantime” will still be in good shape and not need retrofitting. In addition, building users may not wish to be bothered further. Often, there simply is not enou... nsus. Ideally, windows and façades should always be retrofitted simultaneously whenever possible. Whe
Airtightness measurements in Passive Houses @planning:airtight_construction
41 Hits, Last modified: 2 years ago
ss measurements in Passive House buildings are to be carried out uniformly worldwide according to ISO ... of the reference volume for passive houses is to be carried out according to the procedure listed bel... part of the ISO 9972. The resulting volume is to be used for the determination of the n<sub>50</sub>-... \\ For the calculation and documentation, it can be helpful to use the "room data", which is included
Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
37 Hits, Last modified: 7 years ago
n moderately insulated building envelopes have to be cooled all throughout the year. Increasingly long... consumption. The primacy of economy will have to be accepted in all cases: turnover is all-important;... the energy demand of retail stores do not have to be economically viable by themselves; above all, they must be compatible with the sales concept. \\ [{{ :picop
Thermal insulation @planning:thermal_protection
37 Hits, Last modified: 4 years ago
ng demand the entire **building envelope** has to be well insulated. The building envelope consists of... ection comes in. -> Good thermal protection can be achieved for **all construction methods** and has... -> An appropriate level of insulation can also be applied to **existing buildings** at any given po... . A high level of insulation has always proven to be effective; to learn more please go to the followi
Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
35 Hits, Last modified: 8 years ago
hools:Passive House schools – requirements]] can be met with justifiable effort. These recommendations are not meant to be requirements – it is possible to deviate from them, but then compensating measures must generally be taken elsewhere. Calculations using the PHPP for ... gs. A/V ratios of less than 0.4 m²/m³ can usually be achieved if the buildings are well-planned, and n
Energy balances - Background @planning:calculating_energy_efficiency
34 Hits, Last modified: 5 years ago
fic area. Consequently, energy balances can only be prepared for restricted spatial areas with clearl... is sinking. However, this is exactly what should be prevented in order to maintain living comfort. Therefore, the energy flowing out has to be replaced: another heat flow must travel from the... eplacement of this heat loss \\ and can therefore be reduced as required by more effective prevention
Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
32 Hits, Last modified: 3 years ago
ll (German) version of the summary given here can be ordered from the following link: [[https://shop.p... ossible today. Furthermore, these statements can be checked by everyone, even regarding the topic of ... es absolute truth. One's own conviction can never be important enough to call into question the dignit... tally: by using statistical methods something can be said about the reliability with which energy can
Thermal protection and modernisation of existing buildings @planning:planning
30 Hits, Last modified: 6 years ago
the refurbishment so that the building owner can be sure that the stipulated optimal standard of ther... hieved and that the implemented measures prove to be adequate. This is all the more important because ... ermal protection measures almost always proves to be uneconomical. The EnerPHit standard requires eith... its ==== At present, EnerPHit certification can be achieved if all energy related building component
Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
30 Hits, Last modified: 3 years ago
internal heat gains was devised below which will be used as a standard value for residential building... aken from the PHPP worksheet IHG. First it must be noted that the fluctuation range of occupancy and... verage values for the model shown here, which may be higher or lower in individual cases. Nevertheless... who inhabit this dwelling; temporary absence will be taken into account later on) can be calculated as
Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
30 Hits, Last modified: 4 years ago
w rates of the school's ventilation system should be based on health and educational objectives and no... lt also shows that the designed values should not be reduced even further. For increased air quantities attention would have to be paid to the resulting reduction in the relative a... y objectives of indoor air quality will certainly be achieved and the problem of low relative humidity
Don’t save on the insulation @planning:thermal_protection
29 Hits, Last modified: 5 years ago
with in the following list. Taking no action will be much more expensive than carrying out insulation ... tter the level of insulation, the more money will be saved. The other features are also positively aff... e are the advantages of good insulation which can be enjoyed by the owner and occupant themselves.\\ \... it, do it right"** is the principle which should be applied to thermal protection. * No exterior
Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
26 Hits, Last modified: 6 years ago
a more efficient heating system, which could not be installed for now. In other multi-family building... the wall insulation; in Step 2, the windows will be replaced and a ventilation system is installed; a... e retrofit of single sides of a building only can be envisaged (Figure 3). [{{:picopen:retrofitting_c... y that the standard being aimed for will actually be achieved after completing all steps. The pre-cert
Types of ventilation @planning:building_services:ventilation:basics
26 Hits, Last modified: 2 years ago
air quality is especially essential and can only be achieved if "used" air is regularly replaced by f... days, the heat losses\\ during strong winds will be intolerably high. Gap ventilation is\\ therefore ... ventilation is insufficient, the air quality will be poor and there will be a risk of condensation occurring. * If too much ventilation takes place, th
Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
25 Hits, Last modified: 6 years ago
Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
25 Hits, Last modified: 2 years ago
Air volumes @planning:building_services:ventilation:basics
25 Hits, Last modified: 6 years ago
Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
23 Hits, Last modified: 6 years ago
Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
22 Hits, Last modified: 3 years ago
Compact HVAC systems @planning:building_services
18 Hits, Last modified: 5 years ago
Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
18 Hits, Last modified: 9 years ago
Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
17 Hits, Last modified: 5 years ago
Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
16 Hits, Last modified: 3 years ago
Why build an airtight house? – Leakage problems @planning:airtight_construction:general_principles
15 Hits, Last modified: 6 years ago
Calculating energy efficiency
14 Hits, Last modified: 5 years ago
Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
13 Hits, Last modified: 6 years ago
Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
12 Hits, Last modified: 6 years ago
Differentiation between Vv and Vn50 values @planning:building_services:ventilation
11 Hits, Last modified: 2 years ago
Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
10 Hits, Last modified: 4 years ago
“designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
10 Hits, Last modified: 6 years ago
Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
9 Hits, Last modified: 6 years ago
Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
9 Hits, Last modified: 6 years ago
Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
9 Hits, Last modified: 6 years ago
Non-residential Passive House buildings
8 Hits, Last modified: 14 months ago
Tools
8 Hits, Last modified: 10 months ago
Airtightness Measurement of High-Rise Buildings @planning:airtight_construction
8 Hits, Last modified: 3 years ago
Ventilation @planning:building_services
8 Hits, Last modified: 18 months ago
Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
8 Hits, Last modified: 2 years ago
PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
8 Hits, Last modified: 12 months ago
Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
8 Hits, Last modified: 3 years ago
Types of glazing and their specific values @planning:thermal_protection:windows
8 Hits, Last modified: 3 years ago
Heating and DHW @planning:building_services
7 Hits, Last modified: 7 years ago
Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
7 Hits, Last modified: 6 years ago
Airtight construction
6 Hits, Last modified: 10 months ago
Climate data tool for the southern hemisphere
6 Hits, Last modified: 4 years ago
Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
6 Hits, Last modified: 23 months ago
Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
6 Hits, Last modified: 6 years ago
Component guidelines for cost-optimal Passive Houses and EnerPHit retrofits
5 Hits, Last modified: 8 years ago
Pressure Loss Calculation Tool
5 Hits, Last modified: 2 years ago
Airtightness test @planning:airtight_construction:general_principles
5 Hits, Last modified: 7 years ago
PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
5 Hits, Last modified: 6 years ago
Outdoor thermography @planning:thermal_protection:thermal_protection_works
5 Hits, Last modified: 3 years ago
Sound generation, sound dispersion and sound proofing in heat pumps @planning:building_services:heating_and_dhw:heating:heat_pumps
5 Hits, Last modified: 7 years ago
Building envelope
4 Hits, Last modified: 10 months ago
General principles for improving airtightness @planning:airtight_construction:general_principles
4 Hits, Last modified: 10 years ago
Thermal protection in retrofits @planning:thermal_protection:thermal_protection_works
4 Hits, Last modified: 11 years ago
Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
4 Hits, Last modified: 6 years ago
Construction site photos list - detailed
3 Hits, Last modified: 2 years ago
PHPP – Passive House Planning Package @planning:calculating_energy_efficiency
3 Hits, Last modified: 12 months ago
Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
3 Hits, Last modified: 7 years ago
Summer Comfort Guideline @planning:summer_comfort
3 Hits, Last modified: 2 years ago
Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
3 Hits, Last modified: 16 months ago
PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
3 Hits, Last modified: 3 years ago
Building Services
2 Hits, Last modified: 24 months ago
Commercial kitchens and cafeterias
2 Hits, Last modified: 3 years ago
Heat pump tool
2 Hits, Last modified: 14 months ago
Summer Comfort
2 Hits, Last modified: 22 months ago
Ventilation tool
2 Hits, Last modified: 4 years ago
Passive House schools @planning:non-residential_passive_house_buildings
2 Hits, Last modified: 5 years ago
Thermal protection works @planning:thermal_protection
2 Hits, Last modified: 6 years ago
The ventilation system – there is no alternative @planning:building_services:ventilation
2 Hits, Last modified: 3 years ago
Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
2 Hits, Last modified: 6 years ago
Passive House swimming pools @planning:non-residential_passive_house_buildings:swimming_pools
2 Hits, Last modified: 13 months ago
Climate data tool
1 Hits, Last modified: 4 years ago
Cooling Systems tool
1 Hits, Last modified: 4 years ago
Guides and Aids
1 Hits, Last modified: 12 months ago
Lift energy demand tool
1 Hits, Last modified: 4 years ago
Refurbishment with Passive House components
1 Hits, Last modified: 20 months ago
Thermal bridge tool
1 Hits, Last modified: 4 years ago
Planning Guidelines for Passive House Indoor Swimming Pools @planning:guides_and_aids
1 Hits, Last modified: 13 months ago
Windows @planning:thermal_protection
1 Hits, Last modified: 5 years ago
Supplying Passive Houses with sustainable energy @planning:building_services:heating_and_dhw
1 Hits, Last modified: 11 years ago
Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
1 Hits, Last modified: 11 years ago
Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
1 Hits, Last modified: 8 years ago
Crosstalk silencers @planning:refurbishment_with_passive_house_components:ventilation
1 Hits, Last modified: 11 years ago

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN