• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » building

building

Search

You can find the results of your search below.

Contains
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning:building_services
  • Any namespace
  • planning:building_services:ventilation (8)
  • planning:building_services:heating_and_dhw (5)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • Compact HVAC systems
  • Heating and DHW
  • Ventilation
  • Heating
  • Supplying Passive Houses with sustainable energy
  • Basics
  • Checklist for Design: Ventilation System in a residential Passive House Building
  • Comparison of energy performance of ventilation systems using passive vs. active heat recovery
  • Differentiation between Vv and Vn50 values
  • Passive House - 6 reasons why you still need opening windows
  • The ventilation system – there is no alternative
  • Experience with drain water heat recovery
  • Heat pumps
  • Air volumes
  • Types of ventilation
  • Sound generation, sound dispersion and sound proofing in heat pumps

Fulltext results:

Ventilation
44 Hits, Last modified: 20 months ago
ty. Read more about: * **Basic: ** [[:planning:building_services:ventilation:basics:types_of_ventilation|... es]] * **Ventilation instruction in refurbished building:** [[https://passipedia.org/planning/refurbishmen... nents/prospects_for_the_modernisation_of_existing_buildings_using_highly_efficient_components/home_ventilati... ventilation**: [[https://passipedia.org/planning/building_services/ventilation/passive_house_-_6_reasons_wh
Types of ventilation @planning:building_services:ventilation:basics
26 Hits, Last modified: 2 years ago
indows twice a day is not enough (see [[[planning:building services:Ventilation:Basics:Types of ventilation#... ventilation – this also applies for ordinary new buildings. The issue here is not energy efficiency, but the health of the building's occupants; Indoor Air Quality (IAQ) has a much ... are used. ===== Ventilation through leaks in the building envelope ===== Gap ventilation through leaks is
Heating and DHW
22 Hits, Last modified: 7 years ago
eating demand in comparison with conventional new buildings. ===== Heating and DHW systems - overview ====... s less installation space in the room. [[planning:building services:heating_and_dhw:Heating and DHW systems|... 6] Using the example of an intensively researched building (low-energy house in Schrecksbach, details of whi... ach, Germany) and a Passive House standard “twin” building derived from this, the overall cost burden and co
Differentiation between Vv and Vn50 values @planning:building_services:ventilation
15 Hits, Last modified: 2 years ago
e TFA times an average room height for the entire building. \\ In the case of residential buildings, a standard height of 2.50 m should be considered, regardless of t... height. | Exact caltulation: \\ All rooms of the building (including the stairs + elevator) are calculated ... than an exact depiction of the volume within the building. For residential buildings on PHPP, it serves to
Compact HVAC systems
14 Hits, Last modified: 5 years ago
this isn't the way to achieve an energy efficient building with a good quality of indoor air. Home ventilat... rbishments! See also the article about [[planning:building services:Ventilation:Basics:Types of ventilation|... he article comparing the efficiency of [[planning:building_services:ventilation:comparison_of_energy_perform... lies for the low cooling loads of a Passive House building. This makes it possible to develop convincingly
Supplying Passive Houses with sustainable energy @planning:building_services:heating_and_dhw
12 Hits, Last modified: 11 years ago
tainable amount. Possible future solutions in the building sector include zero-carbon / zero-emissions buildings, which are already required in some areas. This pape... ussion, suggests a targeted system for evaluating buildings. ===== "Zero carbon" and "zero emission" = "zer... he environment. The "zero carbon" requirement for buildings is therefore a welcome idea in principle, althou
Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
7 Hits, Last modified: 6 years ago
mfortable range (well, and as long as you are not building on Mars, there are only a few exceptions). //Sav... and environmentally friendly way of cooling your building, with cross ventilation offering the most effecti... ned from the inside. Openable windows thus make a building much easier to maintain and can help reduce runni... t of an emergency.\\ There are few Passive House buildings partially or entirely fitted with fixed glazing.
Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
6 Hits, Last modified: 2 years ago
sive systems and an active system, installed in a building according to the International Passive House standard ([[https://passiv.de/downloads/03_building_criteria_en.pdf|criteria]]). The floor area of the investigated building is 145 m². The occupancy is 35 m²/person and fres... supply is 30 m³/(h*person). As a reference, the buildings are equipped with a passive HRV system with an e
Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
5 Hits, Last modified: 6 years ago
rge amounts of water that need to be processed in buildings and how much water can contribute to heating, it... ess gray water. Even the very first Passive House building in Darmstadt-Kranichstein was built with a coolin... ilable exclusively to iPHA members!// [[planning:building_services:heating_and_dhw:experience_with_drain_wa... re so as they become more common. * In bigger buildings, the nominal heat production output and storage
Air volumes @planning:building_services:ventilation:basics
5 Hits, Last modified: 6 years ago
w much air is acceptable? ==== With a [[planning:building_services:ventilation:basics:types_of_ventilation#... tch position during operation in the multi-storey building in Kassel Marbachshöhe) have shown that the syste... t and good air quality in modern (or refurbished) buildings.\\ \\ ===== Air volumes and air humidity are clo... up>-1</sup>, based on the whole house, but as the building is being constantly supplied with fresh air, the
Sound generation, sound dispersion and sound proofing in heat pumps @planning:building_services:heating_and_dhw:heating:heat_pumps
5 Hits, Last modified: 7 years ago
of German Engineers VDI 3731, Sheet 2 [[planning:building_services:heating_and_dhw:heating:heat_pumps#liter... circulation device connected with it: [[planning:building_services:heating_and_dhw:heating:heat_pumps:Excit... ]] {{:picopen:members_only.png?25|}} [[planning:building_services:heating_and_dhw:heating:heat_pumps:Sound... ]] {{:picopen:members_only.png?25|}} [[planning:building_services:heating_and_dhw:heating:heat_pumps:Analy
Basics @planning:building_services:ventilation
4 Hits, Last modified: 7 years ago
====== Basics ====== **[[planning:building services:Ventilation:Basics:Types of ventilation]]** \\ \\ __**A... air volumes, people tend to complain. [[planning:building services:Ventilation:Basics:Air volumes|Read more...]] \\ \\ coming soon: [[planning:building services:Ventilation:Basics:instructions]] \\ \\ ... al Passive House Conference 2013: // [[planning:building services:Ventilation:Basics:Optimization of dwell
Checklist for Design: Ventilation System in a residential Passive House Building @planning:building_services:ventilation
4 Hits, Last modified: 2 years ago
Ventilation System in a residential Passive House Building====== This checklist for the design of a ventilation system in a residential Passive House building has been written to aid building designers. ---- Download the Checklist **[[https://database.passivehous... tchens in Passive Houses Guidelines]] [[planning:building_services:ventilation | Overview ]] of Passipedia
Heat pumps @planning:building_services:heating_and_dhw:heating
4 Hits, Last modified: 7 years ago
====== Heat pumps ====== [[planning:building_services:heating_and_dhw:heating:heat_pumps:Sound generation, ... spersion and proofing in heat pumps]] [[planning:building_services:compact_hvac_systems:certification_and_p... calculation for compact heat pumps]] [[planning:building_services:heating_and_dhw:heating:heat_pumps:Structural soundproofing for building services systems – Proposed approaches for archit
Heating @planning:building_services:heating_and_dhw
3 Hits, Last modified: 7 years ago
====== Heating ====== [[Planning:building_services:heating_and_dhw:heating:Biomass heating in Passive House... ] {{:picopen:members_only.png?25|}} [[Planning:building_services:heating_and_dhw:heating:Heat pumps]] [[Planning:building_services:heating_and_dhw:heating:Passive House he
The ventilation system – there is no alternative @planning:building_services:ventilation
3 Hits, Last modified: 3 years ago

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN