Fulltext results:
- Dynamic simulation of a building's thermal performance
- ====== Dynamic simulation of a building's thermal performance ====== ==== Dynamic Simulation using DYNBIL =... l room model used in instationary simulation of a buildings \\ thermal performance; this is the model-type u... t 1994]| \\ Dynbil is a multizone dynamic thermal building simulation program developed at the Passive House... nd ventilation models. Although DYNBIL models the building components very accurately (see e.g. comparison o
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Commission, in which urban settlements and larger building projects in the Passive House Standard were built... demonstrated that the thermal characteristics of buildings - even in the case of Passive Houses - could be ... red results; - incidentally this was true for all building standards. \\ \\ |{{ :picopen: comp_PHPP_measurem... on and already published before completion of the buildings. \\ \\ Mitchell and Natarajan investigated a lar
- Energy balances - Background
- ce" or more precisely: it includes all areas in a building in which comfortable thermal conditions should pr... lope is seen primarily in pragmatic terms: for a building it is particularly convenient to opt for the bala... n the outside of the thermally insulated external building components. (**__Fig. 1__**) The purpose of heat... emperature comfortable, i.e. constant, inside the building being considered (see [[Planning:calculating ener
- PHPP – Passive House Planning Package
- ce and calculates the annual energy demand of the building based on the user input relating to the building's characteristics.\\ The main results provided by this sof... hod_for_determining_thermal_comfort_in_summer_for_buildings_without_active_cooling|passive cooling tool]] )\\ * Annual primary energy demand for the whole building [kWh/(m²a)] The actual PHPP programme is based o
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- ssumptions for internal heat gains in residential buildings in the PHPP 9// \\ \\ \\ At the 18th Passive H... lues for internal heat gains (IHG) in residential buildings [Grant 2014]. For the UK they ascertained that h... will be used as a standard value for residential buildings in the PHPP 9 (2015). The calculations were perf... e will also change during the service life of the building, therefore these are only estimated average value
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- e and easy-to-use tool for planning Passive House buildings and EnerPHit retrofits. It is also accepted as p... tion was drawn up, allows users to input a single building with its geometry and the heat insulation properties of its building components etc. and calculates an energy balance ... to calculate various design options for the same building. This may arise with modernization projects if us
- The overall heat transfer coefficient or U-value @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- lue ====== In the PHPP worksheet U-Values of all building elements of the building envelope, or, in other words, all building elements through which heat is lost, are listed with their assem... ty (lambda value) of each insulation material and building component must be submitted. For Passive Houses i
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- ble Sketchup ====== **3D modelling tool to input building geometry into PHPP** \\ {{:picopen:designPH_logo... PHI to provide a 3D model interface for entering building geometry into PHPP. The benefits of the tool are ... n for Trimble Sketchup 3D modelling tool to input building geometry into PHPP|Read more]] \\ ===== An iter... allowing the user to get an immediate idea of the building’s energy performance, and rule out poorly perform
- Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- t are heated to a lower temperature than the main building:** * For temperatures above 10 °C these spaces ... conservative approach and is only recommended for buildings, for which the influence on the total specific h... ISO 13789. * For unheated garages attached to buildings, investigations by PHI have shown that the reduc
- PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- f optimising the energy efficiency of residential buildings in cool-temperate climates where the space heati... t has proved its worth in thousands of successful building projects. Meanwhile, the Passive House concept is... tailed comparison of PHPP results of a simplified building model with the equivalent reference values determ