Fulltext results:
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- ====== ===== Basic and airtightness in existing building===== ===== Airtightness – how and why? ===== T... of air flowing in through joints and gaps in the building envelope. A large percentage of building damage is caused by leaks in the building envelope. Sound insulation is reduced, drafts cause discomfort fo
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
- e share of step-by-step retrofit processes in the building retrofit sector is significant: According to a st... t by the German Federal Institute for Research on Building, Urban Affairs and Spatial Development (BBSR) in ... 4, 85 % of the costs for retrofits of residential buildings have been invested into single measures or packa... d retrofit measures after the project completion. Building types and retrofit measures range from single-fam
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
- the compulsory technical inspections of existing buildings. There is a large number of buildings in poor conditions. Their dwellers do not enjoy adequate comfort con... e i ===== 2 Issues for Interventions in Existing Buildings, Especially in Social Housing ===== [{{:picopen:... for an integral technical solution for the whole building to achieve the EnerPHit standard requirements. R
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
- mulsionen) ====== Step-by-step deep retrofit and building integrated façade/roof on a 'million program' hou... === Stacken, a classic Swedish ‘million program’ building with 35 apartments in Göteborg (Gothenburg), whic... a cost effective step-by-step deep retrofit with building integrated solar photovoltaics (BIPV) on the faça... o show the positive synergy effects of installing building integrated solar at the same time as achieving th
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- ving thermal bridges and airtightness in existing buildings ====== ===== Introduction: Old buildings – thermal bridge free? ===== Thermal bridge free design – i.e. ... ving thermal bridges and airtightness in existing buildings#Literature|[AkkP 16] ]] ; [[planning:refurbishme... ving thermal bridges and airtightness in existing buildings#Literature|[AkkP 21] ]]). The advantages are obv
- Prospects for the modernisation of existing buildings using highly efficient components
- ===== Prospects for the modernisation of existing buildings using highly efficient components ====== This a... nents:prospects_for_the_modernisation_of_existing_buildings_using_highly_efficient_components#Literature|[Fe... ]] focuses on the use of highly energy-efficient building components for the modernisation of existing buildings. Originally, these components were developed for use
- Component Award 2016: Affordable ventilation solutions for retrofits
- with heat recovery ===== Seventy percent of the building stock in Germany was constructed before 1989. Solutions that are easy to integrate in such buildings will be crucial towards providing high-quality v... airflow concepts for energy-efficient residential buildings, http://www.phi-ibk.at/luftfuehrung/), the Unive... the ventilation system takes up less space in the building, more floor space is available for active use. Pr
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
- pen:europhit_logo.png|}}]] \\ \\ \\ \\ \\ ====== Building Integrated Photovoltaics (BIPV) in Step by Step R... editerranean climates and not only in residential buildings. Moreover, EnerPHit certification recognises ref... achievement of the EPBD __(Energy Performance of Buildings Directive)__ targets by 2020. Building integrated photovoltaic solutions are capable of fully replacing
- Refurbishment with Passive House components - introduction
- House components in the modernisation of existing building stock was systematically investigated in the 24th... terature|[AKKP-24] ]], and the special aspects of building facades that are worth preserving were dealt with... of pilot projects, the modernisation of existing buildings using Passive House components is finally ready ... |//Calculated (PHPP) heating demand of existing\\ building stock and calculated heating demand\\ and measure
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- e external envelope ====== Modernisation of the building envelope without insulation ("cosmetic refurbishm... period of time [AKKP24]. Depending on the type of building component, these figures may be even more extreme... on details between refurbished and un-refurbished buildings components. If, for example, the exterior wall i... M.; Kah, O.: Passive House technology in existing buildings – Quality Assurance for the Jean-Paul-Platz 4 bu
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
- it measures documented in the region for the same building typology (data gathered from www.observatoirebbc.... rred anyway have been considered for the existing building: windows had to be replaced, so the existing scen... oom height, the ventilation unit is placed in the building core and does not have the highest efficiency on ... rms of total cost and try to make use of what the building offers (existing systems and geometry) to reduce
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
- aylighting ====== ===== Introduction ===== Some building physics projects can have a direct impact on dayl... ures that should be considered when modernizing a building. For instance, light directly impacts building users’ mental capacity and visual perception [Ba 1999]. Ligh... s of available daylight//**|\\ \\ Non-residential buildings can get a lot of their lighting from daylight. F
- Passive House refurbishment - ventilation
- s]] {{:picopen:members_only.png?25}} [[planning:building services:Ventilation:flow rates:Automatic volume ... :Summer situations in refurbished non-residential buildings|Summer situations in refurbished non-residential buildings]] {{:picopen:members_only.png?25}}
- Windows in a step-by-step retrofit
- ood shape and not need retrofitting. In addition, building users may not wish to be bothered further. Often,... utter boxes are one of the major weak points in a building envelope. Generally, roller shutter boxes are not... tight, and it is hard to make them so in existing buildings. The result is high heat losses, even when the r
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- es when fitting a new ground floor to an existing building is to reduce thermal bridging to an acceptable mi... ss and condensation (which in turn may damage the building structure and/or cause mould growth). [{{:picope