Fulltext results:
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- ====== ===== Basic and airtightness in existing building===== ===== Airtightness – how and why? ===== T... of air flowing in through joints and gaps in the building envelope. A large percentage of building damage is caused by leaks in the building envelope. Sound insulation is reduced, drafts cause discomfort fo
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
- e share of step-by-step retrofit processes in the building retrofit sector is significant: According to a st... t by the German Federal Institute for Research on Building, Urban Affairs and Spatial Development (BBSR) in ... d retrofit measures after the project completion. Building types and retrofit measures range from single-fam... flat roofs of only a section of the whole school building. In EuroPHit, a total budget of 26 million Euros
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
- for an integral technical solution for the whole building to achieve the EnerPHit standard requirements. R... an to do an initial study or project. The first building energy refurbishments are now showing damages that did not exist in the building before. They become obvious shortly after finishi... se, single flat and common areas of a residential building retrofit. ==== 3.1 Centón House ==== The Centón
- Component Award 2016: Affordable ventilation solutions for retrofits
- with heat recovery ===== Seventy percent of the building stock in Germany was constructed before 1989. Sol... the ventilation system takes up less space in the building, more floor space is available for active use. Pr... in its own closet or engineering room within the building. It may also be interesting to install decentra... **Devices and components meant to be seen** For building retrofits, another good option is components that
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
- mulsionen) ====== Step-by-step deep retrofit and building integrated façade/roof on a 'million program' hou... === Stacken, a classic Swedish ‘million program’ building with 35 apartments in Göteborg (Gothenburg), whic... a cost effective step-by-step deep retrofit with building integrated solar photovoltaics (BIPV) on the faça... o show the positive synergy effects of installing building integrated solar at the same time as achieving th
- Refurbishment with Passive House components - introduction
- House components in the modernisation of existing building stock was systematically investigated in the 24th... terature|[AKKP-24] ]], and the special aspects of building facades that are worth preserving were dealt with... |//Calculated (PHPP) heating demand of existing\\ building stock and calculated heating demand\\ and measure... each procedure. When it is time for the relevant building component to be renewed anyway, then scaffolding
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
- pen:europhit_logo.png|}}]] \\ \\ \\ \\ \\ ====== Building Integrated Photovoltaics (BIPV) in Step by Step R... nce of Buildings Directive)__ targets by 2020. Building integrated photovoltaic solutions are capable of ... acing conventional construction materials for the building envelope such as skylights, façades, windows, cur... thodology for testing the energetic properties of building envelopes. The main objective of this approach is
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- particular. Fig. 1 shows a section through an old building that is to be modernised. The additional uninterr... en:fig.2_pb24.png?350|}}| |//**Figure 2: Standard building components – status quo**//|\\ The initial assump... rative to also insulate the exterior walls of the building with adequate insulation thicknesses if new airti... , Oktober 2002. Feist, W.; John, M.; Pfluger, R.: Building physics monitoring of the construction project Je
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- e external envelope ====== Modernisation of the building envelope without insulation ("cosmetic refurbishm... period of time [AKKP24]. Depending on the type of building component, these figures may be even more extreme... ngs – Quality Assurance for the Jean-Paul-Platz 4 building project in Nuremberg, Final Report, in: Jean-Paul-Platz 4 in Nuremberg – energy-efficient building refurbishment with Faktor 10, final report of the
- Prospects for the modernisation of existing buildings using highly efficient components
- ]] focuses on the use of highly energy-efficient building components for the modernisation of existing buil... nts. For this reason, an increasing range of such building components has been developed in recent years. As... oach also requires significant improvement of the building envelope and the ventilation technology as well a... Funding concept ort he modernisation of existing building stock, on behalf of the „Jetzt!“ Initiative; 1st
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
- it measures documented in the region for the same building typology (data gathered from www.observatoirebbc.... rred anyway have been considered for the existing building: windows had to be replaced, so the existing scen... oom height, the ventilation unit is placed in the building core and does not have the highest efficiency on ... rms of total cost and try to make use of what the building offers (existing systems and geometry) to reduce
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
- aylighting ====== ===== Introduction ===== Some building physics projects can have a direct impact on dayl... ures that should be considered when modernizing a building. For instance, light directly impacts building users’ mental capacity and visual perception [Ba 1999]. Ligh... s used (8 am to 6 pm) with daylight hours. When a building has good daylighting, daylight can cover approxim
- Windows in a step-by-step retrofit
- ood shape and not need retrofitting. In addition, building users may not wish to be bothered further. Often,... utter boxes are one of the major weak points in a building envelope. Generally, roller shutter boxes are not
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- es when fitting a new ground floor to an existing building is to reduce thermal bridging to an acceptable mi... ss and condensation (which in turn may damage the building structure and/or cause mould growth). [{{:picope
- Passive House refurbishment - ventilation
- s]] {{:picopen:members_only.png?25}} [[planning:building services:Ventilation:flow rates:Automatic volume