Fulltext results:
- Thermal comfort parameters
- mal comfort is established when the heat released by the human body is in equilibrium with its heat pr... n as the **comfort range**. It can be determined by Fanger’s equation, documented in ISO 7730 (see al... * the perceived temperatures in the room change by no more than 0.8 °C at different locations. Rega... rridor of the institute)}}] It is exciting that by the requirements of the passive house standard al
- Adaptive versus Heat Balance Comfort Models
- The heat balance models have also been confirmed by many field studies, mostly in air-conditioned off... oader temperature range is considered comfortable by users of free-running buildings because they can ... buildings), a fact that is already accounted for by the heat balance models. Often, vague references ... nly, whereas the same condition would be rated +3 by a subject who rarely experiences such temperature
- Local thermal comfort
- l comfort. This can be explained as follows: * By improving thermal insulation (regardless of the e... peratures at various locations in the room differ by less than 0.8 °C.\\ \\ > ** All the comfort crite... nieders 2002] ]]). - Physiological measurements by Bernhard Lipp objectify the perception of comfort