Fulltext results:
- Addendum concerning the use of vacuum insulation
- mmendations are made: * Panels should be tested by a notified body or other recognized testing insti... n panels (VIP)); performance should be guaranteed by the notified body or testing institute for at lea... etc.) or provide for the installation of services by sub-contractors at a later date by way of suitable gaskets, moldings, etc. * The design of the pane
- PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
- (Primary Energy Renewable) were first introduced by Wolfgang Feist at the 18th International Passive ... d at the building) The PER factor is determined by the simultaneity of available energy resources an... rs in order to account for variations caused e.g. by different user behaviour. [{{:picopen:per_2_en.... and dehumidification are more strongly influenced by the given local climatic conditions. Unfortunatel
- Building Certification
- e of planning. At this stage, problems identified by the certifier can still be easily remedied. The... ate document. Passive Houses are not introduced by law or regulation - they are a voluntarily agreed... house|Passive House buildings]] are characterised by especially high levels of indoor comfort with min... ding on the use of renewable energy sources Step-by-step retrofits can also achieve EnerPHit standard
- The Passive House Classes: Classic, Plus and Premium
- The assessment of the different classes is driven by the //total// primary energy demand, as well as r... ed search to filter for Passive House or EnerPHit by Class Classic/Plus/Premium. \\ ===== Renewabl... nificant (especially for heating demand, as shown by the PER methodology). For an honest "zero-energy"... st the value of the service, which is represented by the useful space of the building, the so-called “
- Certified Passive House Components
- ary new constructions. These savings are achieved by efficient buildings and efficient building engineering systems and not by living “economically”. Besides careful planning o... early ascertainable criteria which need to be met by Passive-House-suitable products. These criteria a... ned climate zones. All criteria can be expressed by using measurable quantities and tested by using e
- Certification of terraced houses and semi-detached/duplex houses according to Passive House Institute criteria
- plex houses, i.e. houses that have two units side by side): - The criteria are met by the row of terraced housing as a whole, whereby individual houses... ndividual terraced houses of a row is carried out by different parties. **Method 1** is appropriate i... on and set out in written form at an early stage by all relevant stakeholders. It is possible to ce
- Certification of Passive House office buildings @certification:certified_passive_houses
- === Passive House office buildings are certified by the Passive House Institute (PHI) based on a stan... can reasonably be assumed within this time span. By planning the building for a typical use, a high l... ternal gains should be reduced as far as possible by using efficient equipment, external shading etc. ... can only be effectively removed from the building by means of ventilation (esp. night flushing). In
- Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
- rview of the PER approach. Which is then followed by example projects to shed light on how to achieve ... the classes because it provides a starting point by limiting the amount of useful energy made availab... g planning, buildings are not properly optimized. By taking account of renewable primary energy, the P... e budget is applied to hot water supply, followed by household power demand. If biomass is used to cov
- EnerPHit – the Passive House Certificate for retrofits
- chinfo_schrittweise_modernisierung_sth.pdf | Step-by-step retrofit to achieve EnerPHit-Standard, the e... me}} {{ :picopen:microsoft_word_-_07_window_step_by_step_retrofit_kk.pdf |Windows in step-by-step retrofits - windows first, then insulation }} [[:cert
- Evaluation of server and server room efficiency for non-residential buildings that exceed the primary energy criterion
- ble. The following text is a guideline elaborated by PHI for the evaluation of servers and server room... vings in the double-digit percentage range simply by using an extremely efficient power supply unit.
- Criteria for buildings in other languages @certification:certified_passive_houses
- and IP units) and Spanish. However, translations by various partners and Passive House organisations