Fulltext results:
- Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
- , Premium: The Passive House classes and how they can be reached ====== // This article is an based on... emium: The new Passive House classes and how they can be reached" presented at the 19th International P... ter all, the low energy demand in a Passive House can sustainably come from regional energy sources. Th... on specific reference projects and shows how you can take your project to the next level. The first se
- Building Certification
- planning, because only practice-oriented planning can be translated into a functioning building at the ... this stage, problems identified by the certifier can still be easily remedied. The [[certification:b... required. This ensures that the designed building can really produce the results expected of it in prac... ive House Classes]] **Classic, Plus or Premium** can be achieved depending on the use of renewable ene
- Evaluation of server and server room efficiency for non-residential buildings that exceed the primary energy criterion
- h energy consumption and high processing capacity can be just as efficient as a server with a low energ... ervice is efficient or not, the power consumption can be put into relation to the computations carried ... the current hardware generation is selected, one can be sure that the processor is designed to be as e... over-dimensioned, nor under-dimensioned), then it can be ensured that the biggest energy application of
- Certification of buildings in which the ground floor is used for commercial purposes (for PHPP 9, revised 5-Sep-2016)
- diabatic. In the stairwell area etc. the boundary can also be at the ceiling level even if an air space... eed those for the other floors. Alternatively, it can be ensured that the ground floor will always be k... e entire building), in which case the certificate can subsequently be extended to the entire building a... round floor with which the Passive House Standard can be achieved for the entire building. This will be
- PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
- rily stored before it is used. Short-term storage can technically be achieved fairly efficiently, whils... larger proportion of the associated energy demand can be used directly without need for temporary stora... be treated differently in the calculations as it can easily be stored and used on a demand basis. In f... amples are shown in Figure 4). In some cases this can lead to factors below one, which would mean that
- Addendum concerning the use of vacuum insulation
- . Their relative slimness means that low U-values can be reached, even with very narrow wall constructi... typical building life cycle of 60 years. Failure can lead to low interior surface temperatures, which can, in turn, result in surface condensation and moul... e of panels for the foreseeable future, unless it can be demonstrated that this would fall under nation
- Certification of Passive House office buildings @certification:certified_passive_houses
- m as a Passive House under all circumstances that can reasonably be assumed within this time span. By p... in theory easier to reach. On the other hand, it can cause problems during hot summer periods. It is i... be needed to ensure summer comfort. The same PHPP can be used to calculate both scenarios, based on the... al shading etc. and any excess heat during summer can only be effectively removed from the building by
- Certification of terraced houses and semi-detached/duplex houses according to Passive House Institute criteria
- vidual houses (usually the end-of-terrace houses) can have an energy demand that is slightly higher tha... of thermal protection (insulation thickness etc.) can be implemented and only one PHPP calculation is n... zoning regulation which applies as a general rule can be found in the section "Boundary conditions for
- The Passive House Classes: Classic, Plus and Premium
- intuitive, this approach presents challenges and can be very misleading: * In a "net" energy balanc... e additional energy needs to cover storage losses can, however, be quite significant (especially for he... s have the same efficiency level, the multifamily can achieve the same PH Class rating as a single fami
- Building Criteria: Overview of Changes
- y, Passive House buildings and EnerPHit retrofits can be classified into one of three classes. A partic... the criteria were adapted in such a way that they can now be applied without any restrictions in all cl
- EnerPHit – the Passive House Certificate for retrofits
- Significant energy savings of between 75 and 90 % can be achieved even in existing buildings, for which... gs. To know more about the EnerPHit-Standard you can also visit the corresponding section in the Passi
- Certified Passive House Components
- pecified for defined climate zones. All criteria can be expressed by using measurable quantities and t... ents and the specific values that have to be used can be rather difficult. Specific values as described