certification:certified_passive_houses:example_documents

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
certification:certified_passive_houses:example_documents [2023/04/26 16:33] gergina.radeva@passiv.decertification:certified_passive_houses:example_documents [2025/11/24 09:38] (current) yaling.hsiao@passiv.de
Line 13: Line 13:
 Sample {{:picopen:sample_window_schedule.pdf|window schedule}} Sample {{:picopen:sample_window_schedule.pdf|window schedule}}
  
-Sample {{ :picopen:glazing_characteristics.pdf |glazing data sheet}} +Sample {{:picopen:glazing_characteristics.pdf|glazing data sheet}}
  
-Sample {{ :picopen:uf_value_calculation.pdf |window frame U value calculation}} in accordance with EN ISO 10077-2+Sample {{:picopen:uf_value_calculation.pdf|window frame U value calculation}}  in accordance with EN ISO 10077-2
  
-Sample {{ :picopen:glazing_edge_thermal_bridge_calculation.pdf |glazing edge thermal bridge calculation}} in accordance with EN ISO 10077-2+Sample {{:picopen:glazing_edge_thermal_bridge_calculation.pdf|glazing edge thermal bridge calculation}}  in accordance with EN ISO 10077-2
  
-Completed mm documentation of flow rate adjustment mm  (commissioning of the ventilation system) based on the “ventilation specification sheet”+Completed {{:picopen:final_protocol_worksheets_ventilation_example.pdf|documentation of flow rate adjustment}}  (commissioning of the ventilation system) based on the “ventilation specification sheet”
  
-Record of an {{:picopen:blowerdoortest_report.pdf|airtightness test}}+Record of an {{:picopen:blowerdoortest_report.pdf|airtightness test}}  according to EN 13829, Method A 
 + 
 +Record of an {{:picopen:blowerdoortest_report_according_iso9972.pdf|airtightness test}}  according to ISO9972:2018-12
  
 Completed {{:picopen:enerphit_retrofit_plan_mfh.pdf|EnerPHit Retrofit Plan}}  for a staged renovation to the EnerPHit Standard Completed {{:picopen:enerphit_retrofit_plan_mfh.pdf|EnerPHit Retrofit Plan}}  for a staged renovation to the EnerPHit Standard
Line 31: Line 33:
 Guidance on documenting a {{:picopen:thermal_bridges_to_ambient_air.pdf|thermal bridge calculation}}  for a connection detail adjacent to ambient air Guidance on documenting a {{:picopen:thermal_bridges_to_ambient_air.pdf|thermal bridge calculation}}  for a connection detail adjacent to ambient air
  
-Guidance on documenting the calculation of a window profile and a {{:picopen:window_installation_thermal_bridge_calculation.pdf|window installation thermal bridge}}+Guidance on documenting the calculation of a window profile and a {{ :picopen:window_installation_thermal_bridge_calculation.pdf |window installation thermal bridge}}
  
 Guidance on the calculation of thermal bridges for building assemblies in contact with the ground: Guidance on the calculation of thermal bridges for building assemblies in contact with the ground:
Line 41: Line 43:
  
 Checklist for the report of the [[:planning:airtight_construction:general_principles:checklist_test_reports_of_airtightness_measurements|airtightness test]] Checklist for the report of the [[:planning:airtight_construction:general_principles:checklist_test_reports_of_airtightness_measurements|airtightness test]]
 +
 +Simple and extended checklist for [[:planning:construction_site_photos_list_-_detailed|building site photographs]]
  
 Template for the {{:picopen:construction_manager_declaration.pdf|Construction manager declaration}} Template for the {{:picopen:construction_manager_declaration.pdf|Construction manager declaration}}
  
-Checklist {{:picopen:building_site_pictures_list_passive_house_building_certification.pdf|Building site photographs}}+Template for the {{:picopen:declaration_moe.pdf|Construction manager declaration in French}} 
 + 
 +Template for the {{:picopen:declaracion_director_obra.pdf|Construction manager declaration in Spanish}}
  
 ---- ----
certification/certified_passive_houses/example_documents.1682519598.txt.gz · Last modified: by gergina.radeva@passiv.de