Fulltext results:
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- btracted from the building volume). If the floor construction or suspended ceiling is not yet present or comple... planning of the airtightness – whether for a new construction or for a refurbishment of an old building (based ... prevent any deficiencies in the workmanship, all construction details should be as simple to carry out as possi... ably **large uniform** areas with a simple basic construction * selection of reliable and proven basic const
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- lf bricks“ masonry is typical for plastered solid constructions built before the Second World War. The “24cm ver... lly perforated brickwork” stands for slender wall constructions of the 50s and 60s, and also for those in the 70... e to transfer the planning principles for the new construction of Passive Houses to modernisations of old buildi... f airtightness, the same rules apply as for a new construction, but specific solutions needs to be worked out fo
- Refurbishment with Passive House components - introduction
- ic principle applies to older buildings and new\\ constructions alike. If it is properly carried out, the facade... mp walls, also at areas with outside connections. Constructions that are well-insulated on the outside remain fr... rature|[Vallentin 2008] ]]). * even today, the construction costs remain within reasonable limits – although ... |Passive House refurbishment - ventilation]]\\ [[construction:quality_assurance:nuremberg_case_study|Quality As
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
- hment will be performed step by step. Most of the construction works will be undertaken by the owner (self-construction refurbishment). [{{:picopen:centon_house_left_origin... as a first step of a complete refurbishment. The construction and building services are typical of the 1960’s a... Most of the thermal bridges are eliminated by the construction of a continuous inner insulation layer, which is
- Prospects for the modernisation of existing buildings using highly efficient components
- y, these components were developed for use in new constructions. In order to make full use of innovative technol... e limit (heating load smaller than 10W/m²) in new constructions therefore justifies the use of particularly effi... 39ff. Simons, P.: Refurbishment of half-timbered construction using 12cm interior insulation; Measurement of mo
- Component Award 2016: Affordable ventilation solutions for retrofits
- Intelligent Energy Europe Programme. Residential construction and real estate companies ABG Frankfurt Holding,
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
- tions are capable of fully replacing conventional construction materials for the building envelope such as skyli
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
- wood log stove in the living room. See photos and construction details on http://europhit.eu/op20-house-st-cyr-a