As stated in Energy sufficiency – an introduction. Concept paper for eceee (2018), “Energy sufficiency is a state in which people's basic needs for energy services are met equitably, and ecological limits are respected.”

It goes beyond energy efficiency: having enough but not using too much. In the past, some of these measures were enforced by law. However, this did not always contribute to acceptance among the public. Higher levels of public participation can be achieved by implementing energy efficiency measures, which require more minor behavioural change and compromise. Ideally, these measures will be executed when a building component already requires replacement at the right time in the part's lifecycle. If such improvements are undertaken systematically throughout the components' lifecycles, then the building's overall energy efficiency will be significantly enhanced. Thus, legally enforced restrictions to implement energy sufficiency, often extremely unpopular, can be avoided.

However, sometimes sufficiency is necessary, especially when energy savings are needed rapidly. In this case, it would then be sensible to undertake such measures so that neither injury to health nor material damage to the structure arises - with these pages; we want to help provide the know-how for this.

Room temperature reduction

This measure is easy to achieve: heating less and lowering temperatures during winter always saves energy (and thus costs and emissions). This can include:

  • Setting the average heating temperature to a lower level
  • Temporarily decreasing the heating temperature and frequency
  • Applying partial heating (not heating some rooms or heating less).

All three changes to our behaviour can be adopted in almost any building, whereby lowering the average temperature to heat can almost always be applied. However, when temporarily decreasing the heating temperature or frequency or using partial heating, increased humidity levels may occur in unheated rooms. This can lead to mould growth and ensuing structural damage or health concerns. However, this situation can be avoided by using additional ventilation in winter when air humidity levels are too high (relative humidity > 55%).

Thermal comfort in the room

Did you know that the internal temperature considered comfortable or “bearable” depends significantly on the clothing occupants are wearing! A sweater acts as an extra layer of thermal insulation for the body. The temperature required for optimal thermal comfort when wearing a sweater is approximately 3 degrees Celcius lower than that with just a long-sleeved shirt. Lowering the average heating temperature by three degrees can save 18 to 30 % heating energy. The percentage of energy saved by decreasing the thermostat is even higher in better-insulated buildings; however, the absolute values are so small that the difference plays a less significant role.

Temporary reduction

If the set temperature is reduced only temporarily, e.g. when leaving the building or at night, then the internal temperature, especially of the building components and furnishings, only decreases gradually from time of reduction onwards. This reduces unnecessary energy use when the building is unoccupied, or the occupants are unlikely to notice the internal temperature change (e.g. are asleep). However, the heat output is initially much higher when switching on the heating after the setback because the building components must first be heated up again. Nevertheless, an energy-saving remains, but this is smaller than is often assumed. Even in already well-insulated buildings, this kind of “night setback” still saves energy, even if it's less than in uninsulated buildings, simply because the temperatures drop less due to lower heat losses through the building envelope. Compared to continuous heating, the savings from consistent night setbacks can amount to around 5% (in a Passive House building) and up to 20% (in an uninsulated existing building); on average, this would be an almost 8% saving across the Central European building stock.

A note for those living in multi-family buildings: out of regard for neighbours, the room temperature should not be below 15°C in Germany. The indoor air humidity should also be regularly checked and, in case of uncertainty, measured 1). If it is higher than 55%, the moisture should be reduced by employing ventilation.

1); low-cost electronic Thermo hygrometers are readily available today.

Partial heating

The situation is similar to executing only partial heating in a selected room, and the moisture damage is more critical. If the cold room (e.g. through the open door) is only heated „a little“ (e.g.15°C) and people stay in the warm room, both the heat and moisture would transfer by the internal air change, and too high humidity could be caused in the unheated room. This is important for old buildings.

If a building is well insulated, the temperatures won't have a huge difference between the room and building envelope. The partial heating can still work, however it doesn’t have a prominent effect.

In the paper [Ahn 2015], it is shown that the achievable range of energy saving can be from 13% (Passive House with high occupancy) to 48% (old buildings with unevenly distributed occupants), the average is around 20%. In fact, partial heating has the greatest saving potential among other sufficiency measures. If users pay attention to the humidity level (in winter and in a cold room, it shouldn’t be more than 55%), this is definitely the measure that can be implemented successfully.

Considering the achievable expectation, it must be taken into account that the situation described here (few heated rooms) has already been partially „implemented“ in many old buildings, either willingly or unwillingly; often some rooms are heated insufficiently or for cost reasons the thermostatic valve isn’t opened in some rooms. Therefor, in such cases the additional savings might be lower than expected.

Heating with the fan heater

In a nutshell, under normal circumstances this is never recommended, including several reasons:

  • The fan heater is loud and disturbing.
  • The resistance wires are heated electrically and become very hot - with these wires passed by the room air; the organic dust in the air can be carbonised (or burned) by the wire. This often causes noticeable smell.
  • With the direct electrical heating systems, the electric power is converted 1:1 into heat. Again this causes a series of undesirable consequences:
  • Cost! Today the electricity prices for the general household use is regularly much higher than the heat from commonly used heating systems: Even though oil and gas prices are expensive, the kilowatt-hour price from traditional heating is always cheaper than that of electricity. The household which uses fan heaters regularly or other similar equipment will clearly notice this in the electricity bill. Besides, the heating consumption in old buildings is much higher than normal household electricity use. For this reason, as long as the traditional heating is working, we do not recomend the use of a fan heater. In contrast different claims are sometimes made in commercial advertisements.
  • Seriously fails the goal! If the goal is to „save Gas“ or to restrain CO2 emissions, then the user in most countries with significant heating will achieve the opposite1). Especially in winter, when everyone uses a heating system, the electricity demand is higher, so there is usually no surplus from renewable energy2). During this period (usually when the fan heater is working), conventional fossil power generation will be needed. In best conditions this can achieve a maximum efficiency of 55%. Each modern furnace using gas requires less fuel. With the fan heater, thus we consume even more gas and produce more CO2 compared with conventional heating. However, the situation might change by having renewable energy, especially wind energy in the future; but this will still need many years to be achieved.

The emergency situation - when the heating system fails

The traditional fan heater can reach 2 kilowatts (maximum). In an old building, a (small) single room may remain to be heated with such an equipment (when the doors3) remain closed). This will only work when all residents in that district don’t have the same electricity demand, otherwise the electricity consumption in these areas will increase severely. This is the situation that we all probably don’t want to experience. Having several fan heaters in the house at the same time will reach the limit of the electricity network (not to mention the cost). In the situation of a supply crisis (e.g. for oil or gas), municipalities and electricity suppliers will inform who, when, and how fan heaters may be used. (The supply will be limited in certain periods. If it doesn’t work this could cause even bigger problems with the electricity network.)

Thus, electric space heating normally should use a heat pump system, which only uses about one third of the electricity to provide the heat. This will also restrain the overall CO2 emission. At least, if electricity isn't generated by coal.

Literature

[Ahn 2015] A study on the impact of different occupant behavior on heating demand; Passive House Institute, Darmstadt 2015

1)