• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » has

has

Search

You can find the results of your search below.

Exact match
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning
  • Any namespace
  • planning:refurbishment_with_passive_house_components (12)
  • planning:calculating_energy_efficiency (10)
  • planning:non-residential_passive_house_buildings (10)
  • planning:thermal_protection (9)
  • planning:building_services (7)
  • planning:airtight_construction (6)
  • planning:planning (1)
  • planning:summer_comfort (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Fulltext results:

Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
13 Hits, Last modified: 3 years ago
count by scientists. The author of this article has already dealt with this topic systematically in 1... ge to reach a very high degree of reliability: it has stood up to each test till today. This does not p... ample.\\ \\ On the face of it, reputable science "has a harder time" than fanatics who believe in the absoluteness of their convictions.\\ \\ Science has always stood up to examination time and time agai
Thermal insulation @planning:thermal_protection
11 Hits, Last modified: 4 years ago
a heating demand the entire **building envelope** has to be well insulated. The building envelope consi... be achieved for **all construction methods** and has already been successfully implemented in solid co... any given point of time. An important principle has been derived from experience with new low-energy ... ulation or storage]]). A high level of insulation has always proven to be effective; to learn more plea
Energy balances - Background @planning:calculating_energy_efficiency
10 Hits, Last modified: 5 years ago
iving comfort. Therefore, the energy flowing out has to be replaced: another heat flow must travel fr... energy costs – whenever the envelope thus formed has a reduced surface area.\\ \\ - ** Isn't it bett... ell known fact that the internal body temperature has a daily rhythm with a maximum occuring some time ... se performed in the evening, an observation which has been confirmed in the present study <Fanger>... I
Outdoor thermography @planning:thermal_protection:thermal_protection_works
10 Hits, Last modified: 3 years ago
shows a blue spot where a fresh layer of plaster has just been added below the window sill. The plaste... lity windows have been installed\\ A scaffolding has been put up in front of the facade with packages ... ing insulated. The uniform image in the area that has already been insulated is a good sign, showing that the insulation has been properly applied. * ** The facade areas
Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
9 Hits, Last modified: 5 years ago
mponents connecting the different zones.| Dynbil has been validated with the detailed measurements in ... space of a double-pane insulation glazing). This has its cause * on the one hand in the complexity ... formation for the individual components: it only has to be guaranteed that the interactions between th... scientific theories - after all, not every model has to be a mathematical one and, in addition, comput
Types of glazing and their specific values @planning:thermal_protection:windows
9 Hits, Last modified: 3 years ago
ows ===== Quality thermal protection for windows has advanced more rapidly than for any other building... w</sub>-value) of windows available on the market has been reduced by a **factor of 8** in the last 40 ... be filled with inert gases, usually Argon, which has a lower heat conductivity than ordinary air. Thus... tions. * An interesting fact is that "glazing" has not become more expensive in spite of the enormou
Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
8 Hits, Last modified: 6 years ago
etrofit measures. The EuroPHit consortium thereby has developed recommendations, products, tools and qu... . In EuroPHit, a total budget of 26 million Euros has been foreseen to start or complete retrofit proce... a have been submitted. • The first retrofit step has been completed and meets the specifications in the ERP. • The primary energy demand has been reduced significantly compared with the init
Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
7 Hits, Last modified: 9 years ago
are not rented but owned. The fact each dwelling has a different owner makes it difficult to perform c... common areas because every change or intervention has to be ratified by the majority of owners. Further... s case studies or observer projects. Each example has been addressed from a different approach, allowin... Centón house is a low-budget detached house that has been vacant for some time (Figure 2). The current
Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
6 Hits, Last modified: 6 years ago
ady insulated internally by 10cm of mineral wool) has been externally insulated with 20cm of expanded p... to be airtight. The ceiling in the unheated attic has already been insulated in the past with 40cm of c... eating an airtight layer. A Polyethylene membrane has been placed below the ceiling brickwork, interior... to shift towards efficiency if the energy source has a low carbon intensity (CO2 tax is only 3% of the
Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
6 Hits, Last modified: 5 years ago
ith 35 apartments in Göteborg (Gothenburg), which has long been run as a cooperative, will demonstrate ... to the “full” Passive House level is planned (and has already partially been implemented) with the step... ecovery (MVHR) was installed. It is a model which has since been certified by the Passive House Institute. It has no special control and only ensures fresh air sup
Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
6 Hits, Last modified: 2 years ago
aintaining at least the same level of comfort. As has already been done with other non-residential buil... hether the clinic sterilizes its own instruments, has its own cafeteria, washes its own laundry, and co... ore than 30 percent even though energy efficiency has not been a focal point for medical and professional appliances the way it has been for household appliances. Figure 1 shows the
Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
6 Hits, Last modified: 10 months ago
rolled ventilation). In particular, airtightness has the following advantages: * prevention of mois... e a negative pressure in the whole house. The fan has a measuring device which gives the air flow rate ... plies regardless of how airtightly the suspension has been carried out. Among other things, this stipul... nd not for decorative reasons. For such areas, it has proved to be practicable if a smooth layer of cem
Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
6 Hits, Last modified: 3 years ago
works|Thermal protection works]] - Solid evidence has been provided by real-life measurements.\\ The f... ck wall (grayish blue). A 275 mm insulation layer has been added to the exterior of the wall and plaste... f ±0.15 °C. An electronic data acquisition device has recorded the measured values at an interval of 30... current state of scientific knowledge. So far it has stood any test. The state of scientific knowledge
Types of ventilation @planning:building_services:ventilation:basics
6 Hits, Last modified: 2 years ago
he building's occupants; Indoor Air Quality (IAQ) has a much higher priority than energy conservation -... as done in a systematic scientific analysis which has been published in the Protocol Volume for the Wor... n Sweden for more than 50 years and since 1980 it has become obligatory to have home ventilation. In G... now become more airtight), but unfortunately this has not been made compulsory. For the Passive House,
Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
5 Hits, Last modified: 7 years ago
s and in the form of halls without columns, which has resulted in a typical building structure, as show... to be appropriate in view of store opening times, has hardly ever been observed in practice. Even if da... ike other efficiency measures, thermal protection has played a rather subordinate role in retail stores... ning in summer is not required, instead the store has to be heated almost all year round to compensate
Calculating energy efficiency
4 Hits, Last modified: 5 years ago
Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
4 Hits, Last modified: 3 years ago
Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
4 Hits, Last modified: 6 years ago
Non-residential Passive House buildings
3 Hits, Last modified: 14 months ago
Tools
3 Hits, Last modified: 10 months ago
PHPP – Passive House Planning Package @planning:calculating_energy_efficiency
3 Hits, Last modified: 12 months ago
Thermal protection and modernisation of existing buildings @planning:planning
3 Hits, Last modified: 6 years ago
Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
3 Hits, Last modified: 6 years ago
Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
3 Hits, Last modified: 23 months ago
Why build an airtight house? – Leakage problems @planning:airtight_construction:general_principles
3 Hits, Last modified: 6 years ago
Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
3 Hits, Last modified: 16 months ago
Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
3 Hits, Last modified: 4 years ago
Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
3 Hits, Last modified: 11 years ago
Airtight construction
2 Hits, Last modified: 10 months ago
Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
2 Hits, Last modified: 6 years ago
Windows in a step-by-step retrofit @planning:refurbishment_with_passive_house_components
2 Hits, Last modified: 9 years ago
Don’t save on the insulation @planning:thermal_protection
2 Hits, Last modified: 5 years ago
Airtightness test @planning:airtight_construction:general_principles
2 Hits, Last modified: 7 years ago
Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
2 Hits, Last modified: 2 years ago
Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
2 Hits, Last modified: 4 years ago
PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
2 Hits, Last modified: 6 years ago
Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
2 Hits, Last modified: 6 years ago
Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
2 Hits, Last modified: 3 years ago
Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
2 Hits, Last modified: 8 years ago
Building Services
1 Hits, Last modified: 24 months ago
Climate data tool
1 Hits, Last modified: 4 years ago
Climate data tool for the southern hemisphere
1 Hits, Last modified: 4 years ago
Commercial kitchens and cafeterias
1 Hits, Last modified: 3 years ago
Data processing tool
1 Hits, Last modified: 4 years ago
Design tools
1 Hits, Last modified: 11 months ago
Scaled pointer
1 Hits, Last modified: 4 years ago
Summer Comfort
1 Hits, Last modified: 22 months ago
Thermal bridge tool
1 Hits, Last modified: 4 years ago
Building envelope
1 Hits, Last modified: 10 months ago
Airtightness Measurement of High-Rise Buildings @planning:airtight_construction
1 Hits, Last modified: 3 years ago
Airtightness measurements in Passive Houses @planning:airtight_construction
1 Hits, Last modified: 2 years ago
Compact HVAC systems @planning:building_services
1 Hits, Last modified: 5 years ago
Ventilation @planning:building_services
1 Hits, Last modified: 18 months ago
Passive House schools @planning:non-residential_passive_house_buildings
1 Hits, Last modified: 5 years ago
Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
1 Hits, Last modified: 7 years ago
Summer Comfort Guideline @planning:summer_comfort
1 Hits, Last modified: 2 years ago
General principles for improving airtightness @planning:airtight_construction:general_principles
1 Hits, Last modified: 10 years ago
Supplying Passive Houses with sustainable energy @planning:building_services:heating_and_dhw
1 Hits, Last modified: 11 years ago
Checklist for Design: Ventilation System in a residential Passive House Building @planning:building_services:ventilation
1 Hits, Last modified: 2 years ago
The ventilation system – there is no alternative @planning:building_services:ventilation
1 Hits, Last modified: 3 years ago
“designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
1 Hits, Last modified: 6 years ago
PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
1 Hits, Last modified: 12 months ago
The overall heat transfer coefficient or U-value @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
1 Hits, Last modified: 11 years ago
Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
1 Hits, Last modified: 3 years ago
Passive House Hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
1 Hits, Last modified: 21 months ago
Passive House swimming pools @planning:non-residential_passive_house_buildings:swimming_pools
1 Hits, Last modified: 13 months ago
Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
1 Hits, Last modified: 8 years ago
Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
1 Hits, Last modified: 6 years ago
Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
1 Hits, Last modified: 6 years ago
PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
1 Hits, Last modified: 3 years ago

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN