Fulltext results:
- Types of ventilation @planning:building_services:ventilation:basics
- f about 0.33 ach (air change per hour), one would have to open the windows wide for 5 to 10 minutes ever... it or not. \\ There are two other things that have changed: - Buildings are more airtight; draught... of existing buildings in Central Europe - and we have heard about this from other Winter cold climates ... l, on the contrary, well insulated external walls have warmer and therefore more dry internal surfaces a
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- insulation directly on the slab, so buried walls have been insulated externally on the perimeter of the... slab with 16cm of extruded polystyrene. Windows have been replaced by Smartwin wood-aluminium frames (... ped with movable shutters. Existing shutter-boxes have been insulated with mineral wool and taped to be ... aced below the ceiling brickwork, interior bricks have then been cut on the external walls to tape the m
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- gramme, deep renovations carried out step by step have been the focus of a consortium of 14 partners all... the costs for retrofits of residential buildings have been invested into single measures or packages of... se study projects with at least one retrofit step have been completed by April 2016, 9 more projects are currently ongoing and will have completed retrofit measures after the project com
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- he same title. In the meantime, many new findings have become available, all of which support this publi... ctivity or the second law of thermodynamics) that have not been "proven". Strictly speaking, that is in ... 't fall below 14°C. The few interior heat sources have a moderating effect on the temperature in the hou... ation. In the meantime, savings of 80% on average have been statistically proved in random samples of hu
- Outdoor thermography @planning:thermal_protection:thermal_protection_works
- ess than 10% of the original figure. These values have been proven through measurements and have been published (see [[planning:refurbishment_with_passive_hou... ike that of the upper floors. New quality windows have been installed\\ A scaffolding has been put up i... s well as the insulation panels (dark grey) which have\\ already been applied from the bottom to the gro
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- uses]] Vol. 33 \\ **1. Each modern school should have __controlled ventilation__ which meets the criter... rovide, unless you keep windows fully open or you have a working mechanical fresh air supply. The first ... er. For increased air quantities attention would have to be paid to the resulting reduction in the rela... is desirable in case of infection risks, we will have to take care for keeping the indoor relative humi
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- . should be used so that ventilation units do not have to be excessively large in order to handle indoor... around-the-clock operation. Up to now, hospitals have generally not tapped this potential. A study cond... more difficult because the filters required often have two or three stages. \\ [[planning:non-residenti... ergy demand for filtration, final pressure losses have to be lowered considerably. Filters need to be re
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- esses producing the waste heat in the first place have been optimized. \\ Hospitals generally require 24-7 operation and have special demands for thermal comfort. Insulation t... the Frankfurt Höchst Clinic.**//|\\ \\ Hospitals have a wide range of processes and devices. Comprehens... ably only truly be possible if such products also have energy labels. It is unrealistic to expect planne
- Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
- in fig. 1. In the meantime, additional features have been added such as simulations of moisture transp... o longer be solved analytically. Already here you have to rely on numerical methods for the solution. To... estion does not arise: simulation and measurement have different functions in the cognitive process and ... ments within very large samples. (All these paths have been used in the development of passive houses.)
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- ly air into neighbouring rooms. These ventilators have very low power consumption of about 1 W. The retu... check of condensate drain). Improved ventilators have considerably reduced the specific power consumpti... lly for small ventilators. The duct networks must have low pressure losses for the ventilators to be eff... ssive power consumption levels. Air volumes also have to be constantly balanced for efficient operation
- Thermal insulation @planning:thermal_protection
- ods. Good insulation and airtight construction have proved to be extremely effective in Passive House... uses is not affordable. Let's figure it out!!// Have another look at the [[planning:thermal_protection... osting you around € 2,500, an investment you will have to make anyways. * Next, you should ask your ... r 15-25 years - just as an uninsulated wall would have to be repainted. After the 20 year loan period h
- Air volumes @planning:building_services:ventilation:basics
- s, people tend to complain.\\ Scientific studies have been carried out regarding **additional ventilati... , noise caused by the air flow and draughts would have a restrictive effect (apart from the energy expen... the multi-storey building in Kassel Marbachshöhe) have shown that the systems are almost always operated... the linear characteristics of the ducting network have to be determined by dimensioning the duct cross-s
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- ssess whether the finished modernisation projects have proved successful in operation. After completion ... /|\\ \\ Thus, the principle to be followed, as we have always maintained, is: if it has to be done, it s... he measures. Many countries and regions in Europe have similar programmes, as in most Austrian States fo... also benefit from all the other advantages, which have already been explained.\\ \\ The following demand
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- cant for some time (Figure 2). The current owners have done a refurbishment to prepare it for their pres... ng 4, 6 and 8 cm of mineral wool inner insulation have been calculated with PHPP software (Table 1). Bec... e on the flat from the inside and no common areas have been affected, neighbourhood association approval... ess. In particular, the airtightness improvements have to be made between the original wall and the ETIC
- Windows in a step-by-step retrofit @planning:refurbishment_with_passive_house_components
- . In the end, once the wall is insulated, it will have thermal bridges from installation, and solar gain... façade is renovated, the window frame can easily have insulation added to it. All other solutions turne... ore or less cold outdoor air, insulation does not have any advantages. It is therefore recommended tha... front-wall mounting system. It is a good idea to have the slats roll to the outside; the guide rails ar
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
- Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens