• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » heat

heat

Search

You can find the results of your search below.

Ends with
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning:thermal_protection
  • Any namespace
  • planning:thermal_protection:thermal_protection_works (5)
  • planning:thermal_protection:windows (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • Energy use for heating in a well insulated new building

Fulltext results:

Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
58 Hits, Last modified: 3 years ago
of the thermal storage capacity of a wall and the heat gains from solar radiation are insufficiently, or... e the scientific community of applying laws (e.g. heat conductivity or the second law of thermodynamics)... erature doesn't fall below 14°C. The few interior heat sources have a moderating effect on the temperatu... although it is not "absolutely" certain that the heat equation correctly describes the thermal processe
Thermal insulation
37 Hits, Last modified: 4 years ago
s usually higher than it is outside. As a result, heat is lost through the envelope and, unless this heat is replaced, the inside of the building cools down a... t climates (or during hot periods) with excessive heat entering the building through its envelope. Therefore, it makes sense **to restrict the heat flow** in any building irrespective of the climat
Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
24 Hits, Last modified: 3 years ago
tside temperatures\\ since it is protected by the heat insulation. The measurement values are exactly\\ ... The measurement results clearly indicate that the heat insulation works: * Throughout the entire pe... is room throughout the entire period of time. The heat is provided exclusively by the sun entering throu... e close to that of the room air. Extremely little heat is lost through the wall and can be compensated f
Types of glazing and their specific values @planning:thermal_protection:windows
17 Hits, Last modified: 3 years ago
han for any other building component. The overall heat transfer coefficient (U<sub>w</sub>-value) of win... -value was about **5.5 W/(m²K)**, * the annual heat losses through 1 m² of such a window were equival... er to about **2.8 W/(m²K)**, which means that the heat losses are about half of those of the single glaz... dew point (see picture right hand side). * The heat losses cost about € 21 per m² each year - and tha
Outdoor thermography @planning:thermal_protection:thermal_protection_works
16 Hits, Last modified: 3 years ago
aphs – the only difference being that they depict heat rays instead of visible light.\\ \\ |{{ :picopen:... the outdoor air; therefore they neither give off heat nor do they absorb heat. * ** The temperatures measured for the areas of the facade that have alr... fact, the temperature difference is due to small heat losses which remain even with the wall being insu
Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
14 Hits, Last modified: 6 years ago
Measurements ===== The following image shows the heat consumption data recorded in a highly insulated b... entral European buildings. In fact, the amount of heat required is negligibly small – so small that such... indows. The ventilation system is equipped with a heat recovery unit. If even a single element of this concept did not work as planned, the heat loss would be considerably higher and the expecte
Don’t save on the insulation
9 Hits, Last modified: 5 years ago
has actually proved to be the decisive factor for heat loss. Built and functioning Passive Houses are th... ting loads can be dealt with easily: 400 watts of heat are provided by 4 light bulbs of 100 watts each.\... not enough, therefore a special high performance heat supply system is required.))| 4.5 kW | 1.6 ... |Still too much –\\ just for compen-\\ sating the heat\\ losses through\\ the external walls.|400 Watt -
Thermal protection works
2 Hits, Last modified: 6 years ago
dings as well as older buildings retrofitted with heat insulation. In all cases, this evidence is based ... == A detailed study on the cost-effectiveness of heat insulation is included in the publication "Bewert
Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
1 Hits, Last modified: 6 years ago
i 2010]** DELPHIN: Simulation program for coupled heat, air, moisture, salt and VOC transport. Available

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki