• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » heat

heat

Search

You can find the results of your search below.

Starts with
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning:thermal_protection:thermal_protection_works
  • Any namespace
  • planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • Energy use for heating in a well insulated new building

Fulltext results:

Insulation vs. thermal mass
70 Hits, Last modified: 3 years ago
of the thermal storage capacity of a wall and the heat gains from solar radiation are insufficiently, or... e the scientific community of applying laws (e.g. heat conductivity or the second law of thermodynamics)... ion", for example:\\ * What happens, when the heating system of an old building breaks down in winte... ower vase froze. * And what happens when the heating in a Passive House breaks down? Even at minus
Insulation works – Evidence no.1 "Measurements at a highly insulated wall"
27 Hits, Last modified: 3 years ago
tside temperatures\\ since it is protected by the heat insulation. The measurement values are exactly\\ ... The measurement results clearly indicate that the heat insulation works: * Throughout the entire pe... m!); the mean temperature is 24 °C. Note that the heating system was not turned on in this room throughout the entire period of time. The heat is provided exclusively by the sun entering throu
Energy use for heating in a well insulated new building
24 Hits, Last modified: 6 years ago
====== Energy use for heating in a well insulated new building ====== Here is further evidence that ins... Measurements ===== The following image shows the heat consumption data recorded in a highly insulated b... }}| |//**This diagram shows the recorded data for heating energy.\\ Left: Average consumption in existin... 0 kWh/(m²yr).\\ All other values: energy use for heating measured in the terraced house in Darmstadt\\
Outdoor thermography
20 Hits, Last modified: 3 years ago
aphs – the only difference being that they depict heat rays instead of visible light.\\ \\ |{{ :picopen:... t in an exemplary way reducing the energy use for heating to less than 10% of the original figure. These... the outdoor air; therefore they neither give off heat nor do they absorb heat. * ** The temperatures measured for the areas of the facade that have alr
Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
2 Hits, Last modified: 6 years ago
low, uncomfortable surface temperatures and high heating demands. In order to produce comparable therma... i 2010]** DELPHIN: Simulation program for coupled heat, air, moisture, salt and VOC transport. Available

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN