Fulltext results:
- Thermal insulation
- ===== In low-energy buildings in climates with a heating demand the entire **building envelope** has to be... the air temperature, irrespective of the type of heating used. This leads to a very high level of [[basic... tly well based on these calculations. In terms of heating, they require as little as 10 percent of the ener... l central European buildings: about 1.5 litres of heating oil per square metre and year compared with 15 or
- Don’t save on the insulation
- reased and there are better options for effective heating. These are the advantages of good insulation whic... e the best proof of that: they hardly require any heating energy ([[Operation:Operation and Experience:Meas... /(m²K) | 0.125 W/(m²K) | ^Annual demand for heating oil\\ (per 1 m² wall)(( Calculation basis: average location in Germany with 3250 heating degree days at an indoor temperature of 20 °C and
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- ion", for example:\\ * What happens, when the heating system of an old building breaks down in winter? ... ower vase froze. * And what happens when the heating in a Passive House breaks down? Even at minus tem... d the air exchange are mainly responsible for the heating energy consumption of a house in Central Europe. ... adiation on external wall surfaces in the average heating period is usually an insignificant effect with ve
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- ====== Energy use for heating in a well insulated new building ====== Here is further evidence that insula... }}| |//**This diagram shows the recorded data for heating energy.\\ Left: Average consumption in existing b... 0 kWh/(m²yr).\\ All other values: energy use for heating measured in the terraced house in Darmstadt\\ Kr... se an average of 160 kWh of fuel (oil or gas) for heating alone – see statistics from the companies in char
- Types of glazing and their specific values @planning:thermal_protection:windows
- alent to the energy expenditure from 60 litres of heating oil => Assuming average energy prices in Germany... ach square metre of such a window "costs" € 42 in heating energy each year. Not only the energy losses are... losses to less than the equivalent of 7 litres of heating oil per square metre – less than one eighth of th... the room is ensured independently of the type of heating supply. That this was made possible, is due in co
- Thermal protection works
- protection_works:insulation_works_-_evidence_no.2_heating_energy_use_in_a_well_insulated_new_building|Evidence no.2]] - ** Insulation saves energy** - Heating energy use in a well insulated new building \\ \\... enging_connection_details_and_their_impact_on_the_heating_demand|]] [[planning:thermal_protection:thermal_
- Outdoor thermography @planning:thermal_protection:thermal_protection_works
- t in an exemplary way reducing the energy use for heating to less than 10% of the original figure. These va... pecially if there hasn’t been any direct sunlight heating up individual areas of the facade. The last few h
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- m!); the mean temperature is 24 °C. Note that the heating system was not turned on in this room throughout ... advantages it saves a great amount of energy for heating.**\\ \\ ===== Magnified view ===== This magnifie
- Windows
- ld surfaces at the facade and will require active heating near the windows to compensate for cold air drops
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- low, uncomfortable surface temperatures and high heating demands. In order to produce comparable thermal c