Fulltext results:
- Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
- (m²a). It describes the maximum demand for annual heating energy for compliance with the Passive House Stan... ng the amount of useful energy made available for heating purposes indoors. Useful energy demand for coolin... ne are also the same for all three classes. But heating energy demand does not tell the whole story; after all, heating energy demand is roughly equal to hot water deman
- PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
- logical consequence of the temporal correlations, heating – which occurs only during seasons with low RE av... ption: household electricity, domestic hot water, heating, cooling and dehumi¬dification. Examples are show... he local climate data. The remaining profiles – heating, cooling and dehumidification – are determined wi... pecifications as to account for variations in the heating and cooling period: A typical Passive House, as w
- Certification of buildings in which the ground floor is used for commercial purposes (for PHPP 9, revised 5-Sep-2016)
- e upper floors). The area-weighted average of the heating and cooling demands for the ground floor and uppe... ding envelope including the ground floor. e) The heating system on the first floor must be dimensioned ade... of thermal comfort and structural integrity, and heating costs should not greatly exceed those for the oth... tailed construction planning is required. e) The heating system on the first floor must be dimensioned ade
- Certification of terraced houses and semi-detached/duplex houses according to Passive House Institute criteria
- important to take into account the usually higher heating load of the end-of-terrace houses when dimensioning the heating system (supply air heating alone may not be sufficient). The end-of-terrace houses are part of a larger
- The Passive House Classes: Classic, Plus and Premium
- ree classes (relating to useful energy demand for heating and cooling, as well as airtightness and comfort ... s are adjusted slightly to account for the higher heating energy demand limits There are different ways of... an, however, be quite significant (especially for heating demand, as shown by the PER methodology). For an
- Certification of Passive House office buildings @certification:certified_passive_houses
- very significant for the overall performance, as heating the building with losses from office equipment and lighting is equivalent to direct electric heating, which is very disadvantageous solution in terms
- Building Criteria: Overview of Changes
- e of the previous Standards. The requirements for heating and cooling demand remain the same for all classe