- Types of ventilation @planning:building_services:ventilation:basics
- lso applies for ordinary new buildings. The issue here is not energy efficiency, but the health of the b... than energy conservation - but it turns out that there is no conflict at all, if efficient components ar... Accordingly, the air quality is usually poor and there is an increased risk of high air humidity. Becau... s insufficient, the air quality will be poor and there will be a risk of condensation occurring. * If
- Passive House - 6 reasons why you still need opening windows
- t all times? ==== \\ **Wrong** – Absolutely not! There are multiple reasons why there needs to be at least one opening window in each room typically used for ... least this is true for all places on the planet, there external conditions are at least sometimes near t... ll, and as long as you are not building on Mars, there are only a few exceptions). //Saving costs on wi
- Air volumes @planning:building_services:ventilation:basics
- ed on the number of people (30 m³/h per person), there are hardly any complaints about poor air quality.... of absence. Nevertheless, this doesn't mean that there is no need for a three-stage switch (the purge ve... (120 m³/h in the example - DIN 1946 is applicable here), a **relative indoor air humidity of 33.5 %** re... nder the given external\\ air conditions depicted here, the relative humidity of the room\\ reaches slig
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery
- ch energy as a passive heat recovery ventilator. There is only one case where active and passive heat recovery have approximately the same energy demand: the ... st always be identified for a specific building. There are cases (e.g. very mild climates) where direct-passive-heat recovery is not absolutely necessary and
- Checklist for Design: Ventilation System in a residential Passive House Building
- wnload/product_page/ventilation-system-checklist |here]]** for free. ---- [[planning:guides_and_aids:*... cles on **ventilation** Click [[planning:guides_and_aids|here]] to go back to the** Guides and Aids**
- Basics
- ed on the number of people (30 m³/h per person), there are hardly any complaints about poor air quality.
- Differentiation between Vv and Vn50 values
- mean value of all room heights should be entered here. The air volume V<sub>v</sub> is calculated aut
- The ventilation system – there is no alternative
- ====== The ventilation system – there is no alternative ====== Author: Dr. Vajda József, University of