• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » here

here

Search

You can find the results of your search below.

Exact match
  • Exact match
  • Starts with
  • Ends with
  • Contains
@basics:building_physics_-_basics:thermal_bridges:tbcalculation
  • Any namespace
  • basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples (3)
  • basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Fulltext results:

Heated basement @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
6 Hits, Last modified: 3 years ago
oned linear thermal transmittance is given below. Here it should be mentioned that in the Ground workshe... n system however, Option B should also be applied here for determining the Ψ-values. {{ :picopen:beheiz... f the exterior wall can also be calculated easily here from the U-value and the adopted length. The cond... n practice, pre-prepared Excel templates are used here also for determining the Ψ-values. The heat flows
Exterior wall on floor slab @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
5 Hits, Last modified: 3 years ago
rier or sealing layers.// For the example given here, the bottom concrete layer (layer number 19) is d... ext{m}$). $B' = 7{,}992 \, \text{m}$ was selected here (including the exterior wall) //[Note: With some ... package |PHPP]] calculation. In the example shown here, the length of the exterior wall is 2.03 m. The b... an enter the heat flows and the necessary lengths here and the desired Ψ-value is received as the result
Unheated basement @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
3 Hits, Last modified: 3 years ago
$L_{iu}$ were calculated with only 2 simulations here. In this case the desired heat flows must be dete... ext{m}^2\cdot \text{K}}{\text{W}}$ should be used here as well. <WRAP centeralign> **Determining the mi... circ C$, so a $f_{Rsi}$* factor can also be given here. ===== See also ===== * [[basics:building_phy
Special features and characteristics of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
2 Hits, Last modified: 3 years ago
5 °C (on 21.07) in the test reference years shown here only has an impact 91 days later at a depth of 5 m. Here the peak temperature was still 13.1 °C on 20.10.
Basic principle for calculating thermal bridges
1 Hits, Last modified: 3 years ago
The minimum surface temperature can then be read here; however this only refers to the respective tempe