Fulltext results:
- Passive House – the next decade | Determining application-specific PER factors @basics:passive_house_-_assuring_a_sustainable_energy_supply:passive_house_the_next_decade
- House - the next decade” by Wolfgang Feist. Click here to the [[basics:passive_house_-_assuring_a_sustai... day, short-term storage is not the decisive issue here, since financially feasible technology is already... kWh<sub>el</sub> is achieved for the "ideal mix" (here) of 54 percent PV, 36 percent wind, and 10 percen... rrent natural gas network can continue to be used here). \\ \\ |{{:picopen:en_18pht_139_plenum_sanm_feis
- The Passive House in summer
- the Central European climate is being dealt with here, the study initially concentrates on the operativ... eration of the ventilation system, it was assumed here that * the heat recovery (80%) is in operatio... s than 1 % in the reference case being considered here.\\ \\ |{{ :picopen:bas_ohne_lueft_jdl_014.gif?600... re is no temporary shading in the case calculated here!**//||\\ \\ ===== The influence of the window si
- Greenhouse effect and climate protection @basics:energy_and_ecology
- ossibilities for practical measures will be shown here and on the the other pages of passipedia.** Measu... of rich and powerful special interests affected. Here is another video giving some background informati... auses of climate change being observed today, lie here and not in the developing nations. However, many... ialised countries for their development. Because here the use of energy is seen as being smart and a si
- Are Passive Houses cost-effective? @basics:affordability:investing_in_energy_efficiency
- is better to keep the reference areas the same.** Here, we have actually increased the area a little, bu... ings in interest for the example being dealt with here. What the situation will be like later on, is sho... see:// ((**Notice concerning methodology:**\\ \\ Here we have applied the established annuity method us... minal) 2.1 % p.a. 100% payment, 30 year duration, here: * without repayment period. First few years. C
- Heated basement @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
- oned linear thermal transmittance is given below. Here it should be mentioned that in the Ground workshe... n system however, Option B should also be applied here for determining the Ψ-values. {{ :picopen:beheiz... f the exterior wall can also be calculated easily here from the U-value and the adopted length. The cond... n practice, pre-prepared Excel templates are used here also for determining the Ψ-values. The heat flows
- Exterior wall on floor slab @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
- rier or sealing layers.// For the example given here, the bottom concrete layer (layer number 19) is d... ext{m}$). $B' = 7{,}992 \, \text{m}$ was selected here (including the exterior wall) //[Note: With some ... package |PHPP]] calculation. In the example shown here, the length of the exterior wall is 2.03 m. The b... an enter the heat flows and the necessary lengths here and the desired Ψ-value is received as the result
- Internal heat capacity
- ic simulation|article about dynamic simulation]]. Here information can also be found about achieving rel... th this storage process. In the case represented here, the temperature increase between the smallest an... that has been carried out. The simulations shown here were based on the boundary condition of residenti... Apart from that, the summer case study mentioned here also revealed improved levels of comfort, irrespe
- What defines thermal bridge free design? @basics:building_physics_-_basics
- significant, they will not be discussed in detail here. ($\varPsi$ **is the linear,** $\chi $ **the punc... his detail depending on the base point block used here (based on [AkkP 16]}}] [{{:picopen:psi_waermebru... bridge free design” that has often been mentioned here, numerous other details for building envelopes wi... onnections have been presented besides that shown here. If a new building is not built in accordance wi
- Primary energy – quantifying sustainability @basics:energy_and_ecology
- standard set there (same problem with statistics here).\\ -> ** For the "EnEV 2002" category ** with t... standard set there (same problem with statistics here).\\ -> ** The stacking columns for the Passive H... t household appliances are used, the values shown here are typical for modern Passive Houses.((**Primary... energy ==== Grey energy has not been dealt with here. Of course, energy expenditure also plays a role
- Superior thermal protection is affordable @basics:affordability:investing_in_energy_efficiency
- hy it is correct to apply a life cycle assessment here. * In order to avoid speculations about the en... t medium-sized businesses; the businesses located here have a high concentration of employment, so that ... mobilisation of the economic potentials as shown here will have a significant employment effect.\\ \\ G... 005**; The full version of the study can be found here, in German: {{:picopen:wirtschaftlichkeit_waermed
- Thermal Bridges Catalogue @basics:building_physics_-_basics:thermal_bridges
- arising from the use of the information presented here is therefore excluded. |[[https://database.passi... rmal Bridges Tool [[:planning:thermal_bridge_tool|here]]. {{:picopen:sinfonia_eu_phi.png?nolink&300}} ... See also ===== Click [[:planning:guides_and_aids|here]] to go back to the Guides and Aids click [[planning:tools|here]] to go to the "Tool" Further articles about [[
- Local thermal comfort @basics:building_physics_-_basics:thermal_comfort
- ble-glazed window of an old buil-\\ ding is shown here.The average surface tempera-\\ tures are already ... ional\\ window frame is particularly noticeable\\ here. Passive House frames enable a\\ significant impr... is also less air movement. The results presented here are documented in the publication [[basics:buildi... uses experimentally confirm the results presented here ([[basics:building_physics_-_basics:thermal_comfo
- Energy efficiency – the key to future energy supply
- l considered to be “nearly zero” in the case made here – problem solved). However, the “solution” being promoted here goes in the wrong direction, leading to new depen... 2, New edition with footnotes from 2010 available here in German: [[http://www.scribd.com/doc/31156315/P
- The Passive House – historical review
- use" only a new name for "superinsulated homes"? Here are some comments which, although naturally incom... rough the ventilator; yet in spite of this we sit here warm and comfortable, with only a lamp burning. I... rst_passive_house_darmstadt-kranichstein_germany| here]]. The houses have been occupied since 1991. An a
- What is a Passive House?
- ssive House estates. Notice: No "perfomance gap" here. **// |:::| \\ \\ ===== The Passive House has g... ology:Primary energy – quantifying sustainability|here]] to learn about the amount of **primary energy**... Passive House concept works! ==== \\ Please click here to view [[:examples|Passive House examples]]. See
- Efficiency of household appliances and their impact on the primary energy demand of residential buildings @basics:passive_house_-_assuring_a_sustainable_energy_supply
- Passive House – the next decade | Methodology @basics:passive_house_-_assuring_a_sustainable_energy_supply:passive_house_the_next_decade
- Life Cycle energy balances, Embodied energy and the Passive House Standard @basics:energy_and_ecology
- Renewable primary energy demand in residential buildings with high energy intensity @basics:passive_house_-_assuring_a_sustainable_energy_supply
- Special features and characteristics of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
- Introduction - Passive House buildings in different climates @basics:passive_houses_in_different_climates
- Philips Experimental House Research 1974ff: Passive versus Active Measures in Europe & America @basics:the_passive_house_-_historical_review