Fulltext results:
- Thermal insulation
- mperature inside the building envelope is usually higher than it is outside. As a result, heat is lost t... n vs. thermal storage|insulation or storage]]). A high level of insulation has always proven to be effec... al European climate; these values may be slightly higher or lower depending on the climate). These value... f the type of heating used. This leads to a very high level of [[basics:building_physics_-_basics:therm
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- sulation works – Evidence no.1 "Measurements at a highly insulated wall" ====== ===== Long-term measurements at exterior walls of highly insulated new buildings ===== [[planning:therm... ollowing image shows the temperatures measured by high-precision sensors built into the surfaces and the... orks.png?600 }}| |//** Temperatures measured at a highly insulated wall.\\ The entire section of the bri
- Don’t save on the insulation
- bout that...|It won’t be possible to cover\\ such high consumptions in\\ a sustainable way in the future... ary fan heater is not enough, therefore a special high performance heat supply system is required.))| ... in 2011 the energy prices have been more than 35% higher, but in 2016-2020 the average level of ~0.60 €/... uessed quite well. In future it might be somewhat higher due to the need for an energy taxation). The ma
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- ent level of scientific knowledge to reach a very high degree of reliability: it has stood up to each te... eat into the surroundings. This is reflected by\\ high surface temperatures between 6 and 7 °C.\\ -> **O... tremely small.\\ The heat loss through windows is higher. And the tilted window (above left) proves\\ th... se so-called thermal bridge effects can result in high additional heat losses, therefore they must be av
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- nsulation_works_-_evidence_no.1_measurements_at_a_highly_insulated_wall| measurements at a highly insulated wall]]and it is based on the energy consumption data recorded in highly insulated newly built constructions. ===== Meas... age shows the heat consumption data recorded in a highly insulated building, the first Passive House in
- Outdoor thermography @planning:thermal_protection:thermal_protection_works
- sunlight would not be the cause for the slightly higher temperatures of 6.81 °C on average. In fact, t... oor which have not yet been insulated have a much higher average temperature of 9.14 °C. Moreover, their... iated into the surroundings. This is reflected in high surface temperatures between 6 and 7 °C. On the ... This shows that the heat loss is extremely small. Higher heat losses at the windows and the colours arou
- Thermal protection works
- nts have been proven by practical experience with highly insulated new buildings as well as older buildi... sulation_works_-_evidence_no.1_ measurements_at_a_highly_insulated_wall |Evidence no.1]] - **Insulation works** - Temperature measurements at a highly insulated wall \\ \\ [[planning:thermal_protect
- Types of glazing and their specific values @planning:thermal_protection:windows
- ly installed\\ french window here) has somewhat\\ higher surface temperatures (16 °C on\\ average). In t... window frame is particularly noticeable.\\ Such high heat losses and low surface\\ temperatures are no... ===== Conclusion ===== Passive House windows are high quality products which are now produced and suppl
- Windows
- nd “cold radiation” caused by the cold surfaces. Highly insulated windows, on the other hand, will make... contribution to increasing the level of comfort. High performance windows, specifically developed to me
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- with low, uncomfortable surface temperatures and high heating demands. In order to produce comparable t... am heads outside the insulation plane can cause a higher risk of damage by increased moisture contents.
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
- there were not yet any windows on the market with high enough quality. The required thermal qualities co... and worked together with manufacturers to develop high-quality windows for market launch. By now, more t