Fulltext results:
- Types of ventilation @planning:building_services:ventilation:basics
- 's occupants; Indoor Air Quality (IAQ) has a much higher priority than energy conservation - but it turn... losses\\ during strong winds will be intolerably high. Gap ventilation is\\ therefore no longer accepte... is usually poor and there is an increased risk of high air humidity. Because we cannot perceive the ind... ry and energy consumption will become excessively high. => One of the reasons for home ventilation is t
- Thermal insulation @planning:thermal_protection
- mperature inside the building envelope is usually higher than it is outside. As a result, heat is lost t... n vs. thermal storage|insulation or storage]]). A high level of insulation has always proven to be effec... al European climate; these values may be slightly higher or lower depending on the climate). These value... f the type of heating used. This leads to a very high level of [[basics:building_physics_-_basics:therm
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- se of Passive Houses - could be reproduced with a high degree of accuracy using the energy balancing sof... erest is the fact that although there is always a high (relative) user (statistical) spread, the project... of the measurement nor of the calculation is very high. Nevertheless, the depicted values are actual mea... h in the case of passive houses, because even the highest consumption is still very small.\\ \\ ===== Mo
- Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
- for the modernisation of existing buildings using highly efficient components ====== This article (base... for_the_modernisation_of_existing_buildings_using_highly_efficient_components#Literature|[Feist 2003] ]] focuses on the use of highly energy-efficient building components for the mo... ology like compact heat pump units for example, a high standard of thermal protection, increased airtigh
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- gs [Grant 2014]. For the UK they ascertained that higher occupancy rates on average prevailed in smaller... age values for the model shown here, which may be higher or lower in individual cases. Nevertheless, suc... average occupancy density in the UK is up to 20 % higher in smaller dwelling units; with large dwelling ... t was interesting due to the large sample and the high degree of detail. The measurements showed the se
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- Integrated into the countryside, friendly, almost high class – and cost-efficient at the same time: the ... econdary School in Alsfeld in infrared light; the high heat losses through the windows are very noticeab... e_schools_requirements#Literature|[AkkP 30] ]]). Highly-efficient heat recovery from exhaust air is ess... red air**). The volumetric fresh air flow rate is high, otherwise it would lead to significant heat loss
- Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
- internal heat gains becomes negative in spite of high energy expenditure for lighting. Conversely, there are such high heating loads in non-food stores that even modera... ores in the USA. The energy costs are accordingly high; for example, in the food sector these are on a l... ore will not need any active cooling, despite the high loads caused by the lighting (see below). At the
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- (up to 3 hours) in the air. The infection risk is higher, the higher the concentration. Therefor, providing a decent amount of fresh air (which is around some... ween 15 and 20 m³/person/h__ (possibly more for a higher average age of the pupils).**\\ \\ With these r... idity does not even arise.\\ \\ If we go for even higher fresh air flows, what is desirable in case of i
- Thermal protection and modernisation of existing buildings @planning:planning
- irements must simultaneously go hand-in-hand with high cost efficiency of the thermal protection measure... evel of thermal comfort, structural integrity and high quality indoor air. \\ The primary aim of this c... easures only, and buildings are not improved to a high efficiency level such as EnerPHit in the first sh... trofits lead to lock in effects ==== [{{:picopen:high_reduction_potentials_for_step-by-step_retrofits.p
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- sulation works – Evidence no.1 "Measurements at a highly insulated wall" ====== ===== Long-term measurements at exterior walls of highly insulated new buildings ===== [[planning:therm... ollowing image shows the temperatures measured by high-precision sensors built into the surfaces and the... orks.png?600 }}| |//** Temperatures measured at a highly insulated wall.\\ The entire section of the bri
- Don’t save on the insulation @planning:thermal_protection
- bout that...|It won’t be possible to cover\\ such high consumptions in\\ a sustainable way in the future... ary fan heater is not enough, therefore a special high performance heat supply system is required.))| ... in 2011 the energy prices have been more than 35% higher, but in 2016-2020 the average level of ~0.60 €/... uessed quite well. In future it might be somewhat higher due to the need for an energy taxation). The ma
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- ent level of scientific knowledge to reach a very high degree of reliability: it has stood up to each te... eat into the surroundings. This is reflected by\\ high surface temperatures between 6 and 7 °C.\\ -> **O... tremely small.\\ The heat loss through windows is higher. And the tilted window (above left) proves\\ th... se so-called thermal bridge effects can result in high additional heat losses, therefore they must be av
- Compact HVAC systems @planning:building_services
- is not recovered from the used air, there will be high ventilation heat losses – this isn't the way to a... nit, also known as “enthalpy”, isn't particularly high, and condensing moisture contained in the air acc... r such compact ventilation units. These units are highly efficient, as proven by scientifically evaluate... for heating and cooling and dehumidification is a highly attractive integrated system that is easy to in
- Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
- ble for energy inefficient buildings, but lead to high differences in the calculated demand as soon as h... ndoor climate and energy balance results from the high level of complexity which the "house and heating"... ermal behavior of buildings is characterized by a high level of complexity as shown in the last section:... e dependency on the external climate is also very high: In different years at the same Central European
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- ?** \\ The energy efficiency market is subject to high price variability. We can use the phEco model to ... tric), wall insulation. * Normal laws used for high added value components, for which prices have a higher reduction potential due to industrial scaling: w... 7). **6. Was there room for optimization: would higher efficiency pay off?** \\ The ventilation layout
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens