• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin ยป high

high

Search

You can find the results of your search below.

Exact match
  • Exact match
  • Starts with
  • Ends with
  • Contains
@basics:building_physics_-_basics
  • Any namespace
  • basics:building_physics_-_basics:thermal_bridges (4)
  • basics:building_physics_-_basics:thermal_comfort (3)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Fulltext results:

Heating load in Passive Houses
8 Hits, Last modified: 6 years ago
in Passive Houses ====== Due to their extremely high level of energy efficiency, the heating demand in... is actually possible to achieve energy savings as high as 90% compared to conventional buildings [AkkP-2... ry minimal requirements. If occupants requiring a high standard of comfort are present, internal heat ga... ngs with very small heating loads often have very high time constants (anywhere from 5 to 30 days or mor
Definition and effects of thermal bridges @basics:building_physics_-_basics:thermal_bridges
2 Hits, Last modified: 3 years ago
es: the interior surface temperatures are then so high everywhere that critical levels of moisture canno... wever, in general it is not possible to state how high the heat losses due to thermal bridges actually a
Special features and characteristics of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
2 Hits, Last modified: 3 years ago
el of the mean annual temperature is reached. The high phase shifts no longer allow a purely steady-stat... nsional transient numerical calculation is not so high that this extra effort can also be justified (exc
Heat transfer
1 Hits, Last modified: 3 years ago
rences in the tendency to transfer heat are quite high between different materials. Air, as long as it i
What defines thermal bridge free design?
1 Hits, Last modified: 3 years ago
mple changes in the details and without incurring high costs. However, this must be **recognised and tak
Adaptive versus Heat Balance Comfort Models @basics:building_physics_-_basics:thermal_comfort
1 Hits, Last modified: 6 years ago
es far away from comfort (usually correlated with high ambient temperatures), where none of the subjects
Local thermal comfort @basics:building_physics_-_basics:thermal_comfort
1 Hits, Last modified: 6 years ago
veys of a representative number of residents gave high marks for well insulated buildings ([[basics:buil
Thermal comfort parameters @basics:building_physics_-_basics:thermal_comfort
1 Hits, Last modified: 5 years ago
ow is worse, then air speed rises to disturbingly high values. Therefore it is recommended, with "normal
Basic principle for calculating thermal bridges @basics:building_physics_-_basics:thermal_bridges:tbcalculation
1 Hits, Last modified: 3 years ago
and the actual temperatures on the inside are too high. If the dynamic simulations are dispensed with, t
Exterior wall on floor slab @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
1 Hits, Last modified: 3 years ago
ght of the exterior wall should be three times as high as the area to be examined. It is essential that

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN