Fulltext results:
- Types of ventilation @planning:building_services:ventilation:basics
- indispensable in every [[basics:what_is_a_passive_house|Passive House]]. A regular, guaranteed and adequate exchange of air in winter is only possible by means ... rences fluctuate too much in Central Europe. In a house which is not leaky enough for sufficient air exch... oor air pollution. It is correct, and the Passive House Institute shares this opinion, that first of all,
- Compact HVAC systems
- gienically required fresh air supply ===== Every house that is occupied by humans requires fresh air. ... ms (see heat capacity of fresh air). In a Passive House, the heating power requirement is extremely small... so applies for the low cooling loads of a Passive House building. This makes it possible to develop con... ngly simple building services systems for Passive Houses: “heating via ventilation systems”, without the
- Heating and DHW
- he high level of energy efficiency of the Passive House with its reduced heating demand in comparison wit... systems - overview ===== Experiences with Passive House heating systems over many years show that compact... of the Research Group for Cost-effective Passive Houses [AkkP 20] and [AkkP 26] Using the example of an intensively researched building (low-energy house in Schrecksbach, details of which can be found in
- Ventilation
- ts are the most important objectives of a Passive House design. Excellent indoor air quality is indispens... assipedia.org/planning/refurbishment_with_passive_house_components/prospects_for_the_modernisation_of_exi... rg/planning/building_services/ventilation/passive_house_-_6_reasons_why_you_still_need_windows|Passive House - 6 reasons why you still need opening windows]]
- Air volumes @planning:building_services:ventilation:basics
- ditional ventilation through windows** in Passive Houses during the heating period. Although this still o... to change the setting. * Even in single-family houses, the air volumes are only adjusted for longer pe... mes? ==== As early as 1991, in the first Passive House in Darmstadt Kranichstein a moisture and CO2-cont... indoor air. With ordinary moisture sources in the household (330 g/h – varying individually) and “standar
- The ventilation system – there is no alternative @planning:building_services:ventilation
- its small energy consumption, one of the Passive House’s many advantages. In Passive Houses, a healthy indoor climate is achieved in the following ways:\\ *... comfort (see also “Thermal Comfort in the Passive House”), * through controlled home ventilation, which... vel of airtightness of the room meets the Passive House requirement (n50 < 0.6 1/h). * The wind shield
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- ecovery ====== Author: Dr Tomas Mikeska, Passive House Institute ===== Introduction ===== The standard... of residential as well as non-residential Passive Houses is a ventilation unit equipped with a passive he... a building according to the International Passive House standard ([[https://passiv.de/downloads/03_buildi... electricity consumption for heating in a Passive House with a heat pump system. [{{ :picopen:vent_artic
- Differentiation between Vv and Vn50 values @planning:building_services:ventilation
- with detailed rules given in the [[https://passivehouse.com/downloads/03_building_criteria_en.pdf| Criter... lope. ===== Example ===== ==== Single family house - Calculation of TFA, VV and Vn50 ==== | {{:pic... construction:airtightness_measurements_in_passive_houses|Airtightness measurements in Passive Houses]] {{:picopen:members_only.png?nolink&20|}} [[planning:refu
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- ====== Passive House - 6 reasons why you still need opening windows ====== \\ ==== ...do I need to keep ... .// The standard air exchange provided by Passive House ventilation systems generally is far lower, and w... ults suggest that there is little risk of Passive Houses not getting warm or requiring significantly more... e event of an emergency.\\ There are few Passive House buildings partially or entirely fitted with fixed
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
- o process gray water. Even the very first Passive House building in Darmstadt-Kranichstein was built with... edings of the Working Group on Affordable Passive Houses\\ \\ ====== See also ====== [[planning:buildin... nd DHW" [[phi_publications:international_passive_house_conference_contributions_4|List]] of all released... nce proceedings of the 18th International Passive House Conference 2014 in Aachen [[http://www.passiv.de
- Checklist for Design: Ventilation System in a residential Passive House Building @planning:building_services:ventilation
- sign: Ventilation System in a residential Passive House Building====== This checklist for the design of a ventilation system in a residential Passive House building has been written to aid building designe... ownload the Checklist **[[https://database.passivehouse.com/de/download/product_page/ventilation-system-c... ust Systems** for Residential Kitchens in Passive Houses Guidelines]] [[planning:building_services:venti
- Heating @planning:building_services:heating_and_dhw
- eating_and_dhw:heating:Biomass heating in Passive Houses]] {{:picopen:members_only.png?25|}} [[Plannin... building_services:heating_and_dhw:heating:Passive House heating systems in practice]] {{:picopen:members
- Basics @planning:building_services:ventilation
- gs]] of the 17<sup>th</sup> International Passive House Conference 2013: // [[planning:building service