Fulltext results:
- The Passive House in summer @basics
- uildings overheating in summer "due to their high level of insulation" is still one that is frequently ra... nt orientation** – taking account of the type and level of shading and ventilation. The first systematic ... res in this time period gradually increase from a level of barely **25° up to 28 and 30°C**. The surface... house sink perceptibly to constantly comfortable levels during the summer. This is one of several reason
- Playing on the Passive House hill - the new kindergarten in the Heidenau city park @examples:non-residential_buildings:passive_house_kindergartens:central_europe
- building envelope that can be experienced at all levels. The floor plan follows a curved line and the un... tomatically placing emphasis on the entrance. The level side at the opposite end is accessible and can be... and lobby, the standard setting provides a basic level of ventilation. A maximum volumetric air flow i... e group rooms. For this, the users can select two levels on a key switch: partial ventilation and maximum
- What is a Passive House? @basics
- e House buildings are also praised for their high level of comfort. They use **energy sources inside the ... draughts. This is e.g. a guarantee for low Radon levels and improves the health conditions. A highly eff... utely **no cutting back on comfort**; instead the level of comfort is considerably increased (see [[basic... fort ==== The Passive House Standard offers a new level of quality pairing a maximum level of [[basics:bu
- Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
- h; for example, in the food sector these are on a level with the net profit. This may be an incentive for... much higher with around 30 W/m², and illuminance levels may even be higher than 1000 lx. In grocery stor... usses in detail how these can be designed. A good level of airtightness of the remaining building envelop... al heating loads, the issue arises whether a good level of thermal protection would be productive all at
- Don’t save on the insulation @planning:thermal_protection
- acteristics of three different thermal protection levels are dealt with in the following list. Taking no ... Good insulation saves money – and the better the level of insulation, the more money will be saved. The ... o increase the insulation for decades.\\ \\ ===== Level of thermal protection ===== ^ Level of thermal protection ^Typical old\\ external wall ^Moderately insu
- Passive House for municipalities
- ns to improve climate protection at the municipal level, \\ from the building sector perspective. ** // \\ ===== Climate protection at municipal level ===== Climate change affects us all. In order to... hen it comes to climate protection – at the local level, with every individual, every community, in every... tion measures in the building sector at the local level: - [[:municipalities:1ph_legislation_new_build
- The Nestwerk Residential Project in Dresden @examples:residential_buildings:multi-family_buildings:central_europe
- tchen and a large living room are situated on two levels, with ample room height for the living area. On ... The apartments on the top floor extend across one level and are connected to a separate covered staircase... r a dynamic economic feasibility study. A similar level of user comfort was assumed for the analysis, i.e
- Thermal insulation @planning:thermal_protection
- pes of mixed constructions. -> An appropriate level of insulation can also be applied to **existing b... thermal storage|insulation or storage]]). A high level of insulation has always proven to be effective; ... tion is affordable|careful analysis]]. ===== The level of insulation in Passive Houses ===== U-values (... type of heating used. This leads to a very high level of [[basics:building_physics_-_basics:thermal_com
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Zero-energy and zero heating energy houses @basics:energy_and_ecology
- rades professionals to acquire qualitatively high-level advanced training. In order to achieve this, the ... rgy supply really is climate neutral.\\ \\ A high level of energy-efficiency is a prerequisite for the us
- User behaviour @operation:operation_and_experience
- appropriately shaded during the day and **a high level of air exchange is possible at night**. This is ... allow conclusions about the heating consumption levels..\\ \\ |{{ :picopen:korrelation_verbrauch_fenste... d out – but even without it, fresh air and a high level of comfort always exists in the home.\\ \\ =====... http://www.ig-passivhaus.de/index.php?page_id=157&level1_id=75|International Passive House Days]] propert
- Are Passive Houses cost-effective? @basics:affordability:investing_in_energy_efficiency
- s_analysis|]]. These short term changes, however, level each other in the life cycle of the building. Usi... rest rate conditions fixed at a comparatively low level for the next twenty or thirty years. It is rather... alent value of the funding conditions at the same level (difference to the market rate). This means that
- Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
- rimary Energy Renewable]]). Based on the achieved level of energy efficiency and the amount of renewable ... d shows how you can take your project to the next level. The first section provides a general overview of... round*a) (1a). In terms of energy generation, the level of Passive House Plus is reached, and we are not ... that reduces PER demand to 40 kWh/(m²TFA*a). The level of Passive House Plus is then reached for demand,
- Energy balances - Background @planning:calculating_energy_efficiency
- athematical value – and it too increases with the level of insulation and with all types of dead volumes,... ined in such a way that a Passive House with this level of insulation will also function as a Passive Hou... fficient to keep the temperature at a comfortable level. The reduction of heat losses first and foremost
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- Playing in a Passive House - A timber/mudbrick building for children @examples:non-residential_buildings:passive_house_kindergartens:central_europe
- Passive House and the Sustainable Development Goals (SDGs): Connecting an international building standard with global aims @basics
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- Secondary School in Baesweiler, Germany @examples:non-residential_buildings:passive_house_schools:central_europe
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- Riedberg Passive House School, Frankfurt, Germany @examples:non-residential_buildings:passive_house_schools:central_europe
- Economy and financing of efficiency: new buildings, renovation and step by step retrofit @basics:affordability:investing_in_energy_efficiency
- Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Efficiency of household appliances and their impact on the primary energy demand of residential buildings @basics:passive_house_-_assuring_a_sustainable_energy_supply
- Introduction - Passive House buildings in different climates @basics:passive_houses_in_different_climates
- The promotion of low energy construction and the Passive House Standard: Successful strategies for forming a Passive House Association @experiences:connecting_the_passive_house_community
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Software for calculating thermal bridges @basics:building_physics_-_basics:thermal_bridges:tbcalculation
- “Am Buir”, Wassenberg, Germany – the world’s smallest Passive House @examples:residential_buildings:single_-_family_houses:central_europe
- Electric Energy Efficiency for Households – Doing the whole step towards energy efficiency @sinfonia
- PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Energy efficiency of the Passive House Standard: Expectations confirmed by measurements in practice @operation:operation_and_experience:measurement_results
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- The Hanssen-Höppener Passive House @examples:residential_buildings:single_-_family_houses:central_europe
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- Life Cycle energy balances, Embodied energy and the Passive House Standard @basics:energy_and_ecology
- Erfurt University of Applied Sciences – Faculty of Architecture @education_training:university_programmes
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- Factors that influence the energy balance and affordability of non-residential EnerPHit projects @basics:affordability:investing_in_energy_efficiency:economic_feasibility_of_passive_house_retrofits
- St. Josef Caritas-Haus, Germany - the first prefabricated large module Passive House nursing home @examples:residential_buildings:nursing_homes:central_europe
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
- Certification of buildings in which the ground floor is used for commercial purposes (for PHPP 9, revised 5-Sep-2016) @certification
- Evaluation of server and server room efficiency for non-residential buildings that exceed the primary energy criterion @certification
- Philips Experimental House Research 1974ff: Passive versus Active Measures in Europe & America @basics:the_passive_house_-_historical_review
- Danube University Krems, Austria - Postgraduate University Program “Future Building Solutions, MSc” @education_training:university_programmes
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- Passive House – the next decade | Determining application-specific PER factors @basics:passive_house_-_assuring_a_sustainable_energy_supply:passive_house_the_next_decade
- Riedberg Passive House School, Frankfurt, Germany @examples:non-residential_buildings:passive_house_schools
- Checklist for Design: Ventilation System in a residential Passive House Building @planning:building_services:ventilation
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- Lengdorf nursery school, Germany @examples:non-residential_buildings:passive_house_kindergartens:central_europe
- The world’s first Passive House, Darmstadt-Kranichstein, Germany @examples:residential_buildings:multi-family_buildings:central_europe
- Single-family Passive House buildings in Germany and Austria @examples:residential_buildings:single_-_family_houses:central_europe
- Exterior wall on floor slab @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples