@planning:refurbishment_with_passive_house_components
  • Any namespace
  • planning:refurbishment_with_passive_house_components:thermal_envelope (4)
  • planning:refurbishment_with_passive_house_components:ventilation (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Fulltext results:

Refurbishment with Passive House components - introduction
8 Hits, Last modified: 6 years ago
ction measures with insulation thicknesses to the level of the Passive House (see [[planning:refurbishmen... or a long time.\\ Retrofitting with Passive House level insulation is econo-\\ mically ideal under the pr... Retrofitting with insulation to the Passive House level in practice\\ (Foto: Schulze-Darup).//| \\ The... t. The excellent thermal protection of the same level as the Passive House components is not only econo
Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
6 Hits, Last modified: 10 months ago
is too variable to maintain a consistant hygienic level of air exchange and high ventilation heat losses ... ones. In energy efficient buildings an increased level of airtightness is particularly important. The ai... ollution with radon from the ground) An adequate level of airtightness is the basis for: * the use of... ure|[Peper 2000] ]]). Such excellent airtightness levels can also be achieved for modernised buildings if
Component Award 2016: Affordable ventilation solutions for retrofits
4 Hits, Last modified: 6 years ago
eration (Passive House Institute recommends noise levels of ≤ 25 dB(A) in a living room and ≤ 30 dB(A) in... ns can easily lead to excessive power consumption levels. Air volumes also have to be constantly balance... to install and have very good energy consumption levels. The participants are to offer working ventilati... :** When the unit is in constant operation, noise levels must not exceed ≤ 25 dB(A) in living rooms and ≤
Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
4 Hits, Last modified: 9 years ago
since May 2015, and temperature, humidity and CO2 level are being monitored in three rooms (living room, ... en the windows to avoid overheating. The humidity levels are below 50 %. CO2 levels are below 1000 ppm most of the day. ==== 3.3 San Sebastián Social Housing... rtment. Madrid, which has presented air pollution levels above the recommended in the last months, could
Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
3 Hits, Last modified: 5 years ago
ovating other similar buildings could fall to the level that no subventions would be needed for such proj... ==== The renovation to the “full” Passive House level is planned (and has already partially been implem... lar modules is approximately 25 €/m², at the same level as alternative façade and roof materials, and les
Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
3 Hits, Last modified: 6 years ago
bridges that only insulation to the Passive House level can ensure sufficiently high interior surface tem... ght windows are installed. With the Passive House level of insulation on the outside, one can be sure to ... these is to position the airtight envelope at the level of the old exterior plaster. Without careful airt
Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
2 Hits, Last modified: 6 years ago
minating heat and moisture, enhancing the comfort level of the occupants. [{{ :picopen:pv_ventilated_faca... , while simultaneously enhancing interior comfort level. When BIPV solutions are planned to be integrated
Prospects for the modernisation of existing buildings using highly efficient components
2 Hits, Last modified: 7 years ago
Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
2 Hits, Last modified: 6 years ago
insulated exterior wall, each based on different levels of insulation (compound insulation system, EIFS)... ence in investment costs for increased insulation levels is even less significant, as additional costs ar
Crosstalk silencers @planning:refurbishment_with_passive_house_components:ventilation
2 Hits, Last modified: 11 years ago
s to leave the duct. The difference in the sound level between the inlet and outlet section is known as
Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
1 Hits, Last modified: 6 years ago
Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
1 Hits, Last modified: 6 years ago
improved to achieve a high efficiency and comfort level, whereas in non-residential buildings, retrofit m
Windows in a step-by-step retrofit
1 Hits, Last modified: 9 years ago
shading. A position within the future insulation level may be good in terms of installation thermal brid
Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
1 Hits, Last modified: 8 years ago
is family dwelling is pure rock and also has high levels of radon gas emissions. An additional radon-shie