• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » level

level

Search

You can find the results of your search below.

Exact match
  • Exact match
  • Starts with
  • Ends with
  • Contains
@basics
  • Any namespace
  • basics:building_physics_-_basics (8)
  • basics:affordability (5)
  • basics:energy_and_ecology (4)
  • basics:passive_house_-_assuring_a_sustainable_energy_supply (4)
  • basics:passive_houses_in_different_climates (3)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Fulltext results:

The Passive House in summer
16 Hits, Last modified: 4 years ago
uildings overheating in summer "due to their high level of insulation" is still one that is frequently ra... nt orientation** – taking account of the type and level of shading and ventilation. The first systematic ... res in this time period gradually increase from a level of barely **25° up to 28 and 30°C**. The surface... d also have a tool to keep it fixed at a specific level [[operation:operation_and_experience:user_behavio
What is a Passive House?
12 Hits, Last modified: 3 years ago
e House buildings are also praised for their high level of comfort. They use **energy sources inside the ... utely **no cutting back on comfort**; instead the level of comfort is considerably increased (see [[basic... fort ==== The Passive House Standard offers a new level of quality pairing a maximum level of [[basics:building_physics_-_basics:thermal_comfort|comfort]] both
Heating load in Passive Houses @basics:building_physics_-_basics
5 Hits, Last modified: 6 years ago
assive Houses ====== Due to their extremely high level of energy efficiency, the heating demand in Passi... nservatively, i.e. they must ensure a comfortable level of heating for the buildings planned. * The ca... refully: if the cumulated errors exceed a certain level, even the Passive House Standard’s tolerance level will be exceeded and the errors will have an even gre
Passive House and the Sustainable Development Goals (SDGs): Connecting an international building standard with global aims
4 Hits, Last modified: 4 years ago
sources, Passive House substantially improves the level of energy efficiency and encourages energy supply... to mould and moisture damage. Due to their high level of insulation and airtight and thermal bridge-fre... many of the aforementioned issues, but on a city level. Health and wellbeing, resilient and innovative b... gnificantly, close to the new-build Passive House level. EnerPHit can be achieved as a single deep retrof
Primary Energy Renewable PER @basics:energy_and_ecology
3 Hits, Last modified: 13 months ago
the context of individual buildings. The achieved level of energy efficiency and renewable energy supply ... the building in terms of their overall efficiency level and the renewable energy production into three di... vide the energy services. The higher the achieved level of overall efficiency and of renewable energy gen
Efficiency of household appliances and their impact on the primary energy demand of residential buildings @basics:passive_house_-_assuring_a_sustainable_energy_supply
3 Hits, Last modified: 5 years ago
ary energy demand of the building. At a household level, the energy demand from appliances (white goods) ... tterns and potential for savings at the household level is strongly recommended, especially when the buil... iciency. First experiences on evaluations at this level show the potential for savings is high (see more
Planning criteria for Passive Houses in New Zealand @basics:passive_houses_in_different_climates
3 Hits, Last modified: 6 years ago
ation with highly efficient heat recovery. A high level of thermal comfort and excellent air quality can ... becoming increasingly popular on an international level where it must always be adapted to the respective... ) that illustrate the influence of the insulation level of individual constructional elements (wall, roof
Are Passive Houses cost-effective? @basics:affordability:investing_in_energy_efficiency
3 Hits, Last modified: 3 years ago
s_analysis|]]. These short term changes, however, level each other in the life cycle of the building. Usi... rest rate conditions fixed at a comparatively low level for the next twenty or thirty years. It is rather... alent value of the funding conditions at the same level (difference to the market rate). This means that
Economy and financing of efficiency: new buildings, renovation and step by step retrofit @basics:affordability:investing_in_energy_efficiency
3 Hits, Last modified: 6 years ago
and the concept of cost optimality ("cost optimal level") based on life cycle costs has become a major is... the member states have to meet the 'cost optimal level' which is supposed to move in the direction of hi... ential of profit -at least up to the cost optimal level. Otherwise it would become very difficult to mobi
Unheated basement @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
3 Hits, Last modified: 3 years ago
alue ==== The substitute U-value of the basement level is calculated in accordance with Equation 1. Beca... t is assumed that the Base Area A of the basement level based on exterior dimensions correlates with the ... et so that the overall resistance of the basement level can be calculated afterwards with the aid of the
The Passive House - definition
2 Hits, Last modified: 7 years ago
rd but an integrated concept assuring the highest level of comfort. The exact definition is as follows:\\... ion of the energy balance will help determine the level of insulation that will be required in a given bu
The Passive House – historical review
2 Hits, Last modified: 3 years ago
ad taught them the right way to do things: a high level of airtightness, very good insulation, good windo... r quality has always been monitored, and the high level of thermal comfort was confirmed by field measure
Greenhouse effect and climate protection @basics:energy_and_ecology
2 Hits, Last modified: 5 years ago
clearly. (Data up to 2006. \\ In the meantime the level is still continuously rising,\\ e.g. at 414 ppm i... res per square metre remaining). In doing so, the level of **living comfort ** is improved even more. Old
Zero-energy and zero heating energy houses @basics:energy_and_ecology
2 Hits, Last modified: 6 years ago
rades professionals to acquire qualitatively high-level advanced training. In order to achieve this, the ... rgy supply really is climate neutral.\\ \\ A high level of energy-efficiency is a prerequisite for the us
Cost-effectiveness analysis @basics:affordability:investing_in_energy_efficiency
2 Hits, Last modified: 6 years ago
t.\\ \\ ==== Oil prices will determine the price level for a long time to come ==== Even today, crude o... **//|\\ \\ ==== Conclusions for the energy price level in the future (see Fig. 1) ==== Thus we venture
Definition and effects of thermal bridges @basics:building_physics_-_basics:thermal_bridges
2 Hits, Last modified: 3 years ago
Energy efficiency – the key to future energy supply
1 Hits, Last modified: 3 years ago
Internal heat capacity
1 Hits, Last modified: 3 years ago
Passive House - Assuring a sustainable energy supply
1 Hits, Last modified: 14 months ago
Life cycle cost analysis of energy interventions in 18 reference buildings @basics:affordability
1 Hits, Last modified: 6 years ago
Life Cycle energy balances, Embodied energy and the Passive House Standard @basics:energy_and_ecology
1 Hits, Last modified: 4 years ago
Passive House – On-grid or Off-grid? @basics:passive_house_-_assuring_a_sustainable_energy_supply
1 Hits, Last modified: 5 years ago
Passive House – the next decade @basics:passive_house_-_assuring_a_sustainable_energy_supply
1 Hits, Last modified: 14 months ago
Passive Houses in hot, humid climates @basics:passive_houses_in_different_climates
1 Hits, Last modified: 7 years ago
Introduction - Passive House buildings in different climates @basics:passive_houses_in_different_climates
1 Hits, Last modified: 6 years ago
Local thermal comfort @basics:building_physics_-_basics:thermal_comfort
1 Hits, Last modified: 6 years ago
Thermal comfort parameters @basics:building_physics_-_basics:thermal_comfort
1 Hits, Last modified: 5 years ago
Passive House – the next decade | Determining application-specific PER factors @basics:passive_house_-_assuring_a_sustainable_energy_supply:passive_house_the_next_decade
1 Hits, Last modified: 14 months ago
Factors that influence the energy balance and affordability of non-residential EnerPHit projects @basics:affordability:investing_in_energy_efficiency:economic_feasibility_of_passive_house_retrofits
1 Hits, Last modified: 6 years ago
Exterior wall on floor slab @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
1 Hits, Last modified: 3 years ago
Heated basement @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
1 Hits, Last modified: 3 years ago
Special features and characteristics of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
1 Hits, Last modified: 3 years ago

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki