Fulltext results:
- The Passive House in summer @basics
- uildings overheating in summer "due to their high level of insulation" is still one that is frequently ra... nt orientation** – taking account of the type and level of shading and ventilation. The first systematic ... res in this time period gradually increase from a level of barely **25° up to 28 and 30°C**. The surface... d also have a tool to keep it fixed at a specific level [[operation:operation_and_experience:user_behavio
- What is a Passive House? @basics
- e House buildings are also praised for their high level of comfort. They use **energy sources inside the ... utely **no cutting back on comfort**; instead the level of comfort is considerably increased (see [[basic... fort ==== The Passive House Standard offers a new level of quality pairing a maximum level of [[basics:building_physics_-_basics:thermal_comfort|comfort]] both
- Don’t save on the insulation @planning:thermal_protection
- Good insulation saves money – and the better the level of insulation, the more money will be saved. The ... o increase the insulation for decades.\\ \\ ===== Level of thermal protection ===== ^ Level of thermal protection ^Typical old\\ external wall ^Moderately insu... \\ ===== Interior surface temperatures ===== ^ Level of thermal protection ^Typical old\\ external wal
- Thermal insulation @planning:thermal_protection
- pes of mixed constructions. -> An appropriate level of insulation can also be applied to **existing b... thermal storage|insulation or storage]]). A high level of insulation has always proven to be effective; ... tion is affordable|careful analysis]]. ===== The level of insulation in Passive Houses ===== U-values (... type of heating used. This leads to a very high level of [[basics:building_physics_-_basics:thermal_com
- Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
- rimary Energy Renewable]]). Based on the achieved level of energy efficiency and the amount of renewable ... d shows how you can take your project to the next level. The first section provides a general overview of... round*a) (1a). In terms of energy generation, the level of Passive House Plus is reached, and we are not ... that reduces PER demand to 40 kWh/(m²TFA*a). The level of Passive House Plus is then reached for demand,
- Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
- h; for example, in the food sector these are on a level with the net profit. This may be an incentive for... usses in detail how these can be designed. A good level of airtightness of the remaining building envelop... al heating loads, the issue arises whether a good level of thermal protection would be productive all at ... al heat sources.** An x-axis value of 0 shows the level of insulation required according to the German En
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- ction measures with insulation thicknesses to the level of the Passive House (see [[planning:refurbishmen... or a long time.\\ Retrofitting with Passive House level insulation is econo-\\ mically ideal under the pr... Retrofitting with insulation to the Passive House level in practice\\ (Foto: Schulze-Darup).//| \\ The... t. The excellent thermal protection of the same level as the Passive House components is not only econo
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- llution is reduced to a hygienically satisfactory level (subjectively, visitors note that "it doesn't sme... so possible to heat up the rooms to a comfortable level during the preliminary purge phase in the morning... ter the setback phase, reheating to a comfortable level (particularly in relation to the radiation temper... if **the building's envelope surfaces have a high level of thermal protection**. For schools this is the
- Air volumes @planning:building_services:ventilation:basics
- d for a three-stage switch (the purge ventilation level "Party Ventilation" should automatically return t... s and air humidity are closely related ===== The level of relative indoor air humidity in internal space... %** results under these conditions. Usually, this level is comfortable enough if the air is reasonably cl... cient for indoor air hygiene.\\ At this rate, the level of air humidity in the house settles at 41%.**//|
- Heating load in Passive Houses @basics:building_physics_-_basics
- assive Houses ====== Due to their extremely high level of energy efficiency, the heating demand in Passi... nservatively, i.e. they must ensure a comfortable level of heating for the buildings planned. * The ca... refully: if the cumulated errors exceed a certain level, even the Passive House Standard’s tolerance level will be exceeded and the errors will have an even gre
- Certification of Passive House office buildings @certification:certified_passive_houses
- use Institute (PHI) based on a standard occupancy level and corresponding internal gains of 3.5 W/m² (the... y planning the building for a typical use, a high level of efficiency is reached over the entire lifetime... o reduce the internal gains even if the occupancy level is higher than the standard assumption. This is v... ermal comfort in summer:\\ \\ A higher occupancy level essentially leads to higher internal gains, which
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- is too variable to maintain a consistant hygienic level of air exchange and high ventilation heat losses ... ones. In energy efficient buildings an increased level of airtightness is particularly important. The ai... ollution with radon from the ground) An adequate level of airtightness is the basis for: * the use of... es for implementation ==== If a particularly low level of airtightness is expected for a building (many
- Playing on the Passive House hill - the new kindergarten in the Heidenau city park @examples:non-residential_buildings:passive_house_kindergartens:central_europe
- tomatically placing emphasis on the entrance. The level side at the opposite end is accessible and can be... and lobby, the standard setting provides a basic level of ventilation. A maximum volumetric air flow i... tilation and maximum ventilation. If the selected level cannot be achieved by the ventilation system due ... sage periods of the kindergarten, the ventilation level can be selected freely.\\ \\ \\ The supply air in
- The promotion of low energy construction and the Passive House Standard: Successful strategies for forming a Passive House Association
- erts to focus on first and foremost on a regional level may include various environmental, architectural ... professionals that were first involved on a local level included the energy group of the Latvian Chamber ... International networks ==== On an international level, the focus could tend towards expert research ins... nals that were first involved on an international level included the Energieinstitut Voralberg, Tartu Uni
- Passive House and the Sustainable Development Goals (SDGs): Connecting an international building standard with global aims @basics
- The promotion of low energy construction and the Passive House Standard: Successful strategies for forming a Passive House Association @experiences:connecting_the_passive_house_community
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Electric Energy Efficiency for Households – Doing the whole step towards energy efficiency @sinfonia
- Efficiency of household appliances and their impact on the primary energy demand of residential buildings @basics:passive_house_-_assuring_a_sustainable_energy_supply
- PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Economy and financing of efficiency: new buildings, renovation and step by step retrofit @basics:affordability:investing_in_energy_efficiency
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- Playing in a Passive House - A timber/mudbrick building for children @examples:non-residential_buildings:passive_house_kindergartens:central_europe
- Erfurt University of Applied Sciences – Faculty of Architecture @education_training:university_programmes
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- The Nestwerk Residential Project in Dresden @examples:residential_buildings:multi-family_buildings:central_europe
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- Certification of buildings in which the ground floor is used for commercial purposes (for PHPP 9, revised 5-Sep-2016) @certification
- Life Cycle energy balances, Embodied energy and the Passive House Standard @basics:energy_and_ecology
- Introduction - Passive House buildings in different climates @basics:passive_houses_in_different_climates
- Danube University Krems, Austria - Postgraduate University Program “Future Building Solutions, MSc” @education_training:university_programmes
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- Passive House – the next decade | Determining application-specific PER factors @basics:passive_house_-_assuring_a_sustainable_energy_supply:passive_house_the_next_decade
- Riedberg Passive House School, Frankfurt, Germany @examples:non-residential_buildings:passive_house_schools
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- Factors that influence the energy balance and affordability of non-residential EnerPHit projects @basics:affordability:investing_in_energy_efficiency:economic_feasibility_of_passive_house_retrofits
- Riedberg Passive House School, Frankfurt, Germany @examples:non-residential_buildings:passive_house_schools:central_europe
- The world’s first Passive House, Darmstadt-Kranichstein, Germany @examples:residential_buildings:multi-family_buildings:central_europe
- “Am Buir”, Wassenberg, Germany – the world’s smallest Passive House @examples:residential_buildings:single_-_family_houses:central_europe
- Exterior wall on floor slab @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples