- Refurbishment with Passive House components - introduction
- ion that should be asked is: which alternative is more “worthwhile“? The result of these analyses of th... eating system is renewed, a smaller power output (more economical) and a lower flow temperature (more efficient) is sufficient. Even more money is saved with this measure at this point. The excellent the
- Component Award 2016: Affordable ventilation solutions for retrofits
- controlled ventilation with heat recovery becomes more affordable. ===== 2. Aspects of affordable resid... supply and extract air systems) can be built much more efficiently, at lower cost and with lower mainten... ation system takes up less space in the building, more floor space is available for active use. Properly... unit’s effective heat recovery rate is – and the more airtight the building is (Figure 2). [{{:picope
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- side and outside is achieved for large buildings (more than 4000 m³). In order to reduce the volume to ... ³}{hm²}]} $$ </WRAP> The q<sub>50</sub>-value is more suitable for calculating the air transporting dev... rough building components or at the corners where more than two components meet together (at a “point”).... mple. In any case, it has proved to be easier and more cost-efficient if only a few points are assigned
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
- etrofit step have been completed by April 2016, 9 more projects are currently ongoing and will have comp... Standard was implemented completely except for a more efficient heating system, which could not be inst... reseen to start or complete retrofit processes of more than 40.000 m² of floor area to EnerPHit Standard
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
- ic 200 litre hot water tank will be replaced by a more efficient model by 2025, connected to solar therm... ic assessment tool linked to PHPP9. It provides a more detailed view on operational and investment costs
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
- ated and covered with thin film solar modules and more effective crystalline solar modules will be insta... esource suggests that this approach would be even more feasible in areas with better solar resource and
- Windows in a step-by-step retrofit
- nsulated. Because the roller shutter box contains more or less cold outdoor air, insulation does not hav... lding strip is reduced. Krypton, however, is much more expensive than argon, and also the losses at the
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- of building component, these figures may be even more extreme. In the case of a roof, the U-value of an... ing sections of this article. \\ \\ \\ ===== Read more ===== [[planning:refurbishment with Passive Hou
- Prospects for the modernisation of existing buildings using highly efficient components
- well as efficient heating technology. ===== Read more ===== [[planning:refurbishment_with_passive_hou
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
- proved when the old entrance door is changed to a more airtight model and when the airtightness works be
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
- his publication are also quoted. \\ \\ ===== Read more ===== //These in-depth articles are available ex
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- nsidered for each type of ceiling. \\ ===== Read more ===== [[planning:refurbishment_with_passive_hous