Fulltext results:
- Types of ventilation @planning:building_services:ventilation:basics
- aced by fresh air. Opening windows twice a day is not enough (see [[[planning:building services:Ventilation:Basics:Types of ventilation#Purge ventilation ... ies for ordinary new buildings. The issue here is not energy efficiency, but the health of the buildin... rgy conservation - but it turns out that there is no conflict at all, if efficient components are used
- Air volumes @planning:building_services:ventilation:basics
- mes without ventilation systems), therefore it is not energy-relevant or practical! Of course, it is ... the quality of the external air, but in reality, noise caused by the air flow and draughts would have... or air humidity is the primary limiting factor if no humidification is planned for (increased effort f... at the systems are almost always operated at the "Normal" setting in spite of the fact that it is poss
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery
- ion for the ventilation of residential as well as non-residential Passive Houses is a ventilation unit... is carried out for nine different climates across North America. By means of an hourly simulation we c... h/m³. The resulting total electricity demands can now be compared. ===== Investigated systems ===== ... 949 hours with outside temperatures below -3 °C). Note that it is generally not recommended to use sim
- Passive House - 6 reasons why you still need opening windows
- osed at all times? ==== \\ **Wrong** – Absolutely not! There are multiple reasons why there needs to b... a comfortable range (well, and as long as you are not building on Mars, there are only a few exception... laid out for really cold (or hot) periods and may not be too high to keep the air from getting too dry... , in some circumstances such systems can provide another solution. Providing large volumes of air by o
- Differentiation between Vv and Vn50 values
- cessary to ensure an appropriate air quality. For non-residential buildings, the value is merely infor... the calculation of the air exchange rate and does not really influence the calculation of ventilation ... hts in residential buildings it is recommended to not enter a larger value, since this would tend to r... level during the winter that may be too low. For non-residential buildings, the mean value of all roo
- The ventilation system – there is no alternative
- ====== The ventilation system – there is no alternative ====== Author: Dr. Vajda József, University o... drops in temperatures during the winter, traffic noise, insects, outside dust pollution etc.). * Th... equirement has been met, the most sensible and economical option will be to fulfil all the remaining P