Fulltext results:
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- ntelligent Energy –Europe (IEE) programme, deep renovations carried out step by step have been the foc... for a more efficient heating system, which could not be installed for now. In other multi-family buildings, only one dwelling was improved to achieve a high efficiency and comfort level, whereas in non-residential buildings, retrofit measures consist
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- ent Situation ===== Refurbishment projects were not taken into account by the Spanish energy efficie... E) until 2013, when the CTE was updated, and till now comfort and efficiency are not measured in the compulsory technical inspections of existing building... f buildings in poor conditions. Their dwellers do not enjoy adequate comfort conditions or need a huge
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- was conducted under behlaf of the Ministry of Economic Affairs, Energy, Transport, and Housingfor the... download/product_page/PH_Krankenhaus|here.]]** Note: The guide was developed in the German context ... ated into English. Therefore, the translation may not take into account international or country-speci... n Germany with a total of 503,422 beds [[planning:non-residential_passive_house_buildings:ph_hospitals
- Types of ventilation @planning:building_services:ventilation:basics
- aced by fresh air. Opening windows twice a day is not enough (see [[[planning:building services:Ventilation:Basics:Types of ventilation#Purge ventilation ... ies for ordinary new buildings. The issue here is not energy efficiency, but the health of the buildin... rgy conservation - but it turns out that there is no conflict at all, if efficient components are used
- Energy balances - Background @planning:calculating_energy_efficiency
- ore, the energy flowing out has to be replaced: another heat flow must travel from the outside toward... he los-\\ ses as long as the internal energy does not change.**//|\\ \\ * An important note at this point: **The necessity for supplying heat arises on... ious and very effective. If the warmer system is not deliberately isolated ("thermally insulated"), m
- Non-residential Passive House buildings
- ====== Non-residential Passive House buildings ====== The Passive House Standard allows for extremely high levels of comfort as well as enormous energy savings - not only for residential buildings. The Passive House Standard has been success... tandard and experiences gained from their use are now available: The Passive House Standards allows fo
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- iteria 1 to 9 as stated in the article [[planning:non-residential_passive_house_buildings:passive_hous... ith justifiable effort. These recommendations are not meant to be requirements – it is possible to dev... r achieving the Passive House standard [[planning:non-residential_passive_house_buildings:passive_hous... e achieved if the buildings are well-planned, and not unnecessarily broken up – which increases costs.
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- es discomfort and heat losses because the heat cannot be recovered from air lost through building joints (also known as uncontrolled ventilation). In particular, a... lead to increased energy consumption. This should not be confused with __air__tightness that is being ... Pressure test results of old buildings that have not been modernised are often in the range between 3
- Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
- port processes. The room model works with one air node and one radiation node, which are clearly separated from each other. Heat transmitted to interior s... ature and solar radiation in each period of time (nonlinear). The wall model uses not transfer functions but uses a forward difference method, thereby ful
- Commercial kitchens and cafeterias
- ation units to be used. [{{ :picopen:fig1_10.png?nolink&300 |View of the cooking area of a Passive Ho... i_publications:basic_principles]]** **[[planning:non-residential_passive_house_buildings:cafeterias_a... hen and cafeterias]]**{{:picopen:members_only.png?nolink&20|}} **[[planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens:en
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- gains from solar radiation are insufficiently, or not at all, taken into account by scientists. The ... ty or the second law of thermodynamics) that have not been "proven". Strictly speaking, that is in fac... d principles, the serious scientific community cannot thoroughly prove any of its statements.** In fac... lace and enabled the present level of scientific knowledge to reach a very high degree of reliability:
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- fluger in the relevant Protocol Volume [[planning:non-residential_passive_house_buildings:passive_hous... ools_requirements#Literature|[AkkP 33] ]].This is nothing new; these findings had often been made duri... the air quality in schools, but were repeatedly ignored. In the long term however, one can't get arou... anical fresh air supply. The first alternative is not realistic in typical Central European winter con
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- {{:picopen:iee_.png?nolink }} [[http://europhit.eu|{{ :picopen:europhit_logo.png?nolink|}}]] \\ \\ \\ \\ \\ \\ ====== Internal heat ... smaller dwelling units (DU), as a result of which not only body heat from occupants but also the heat ... n from the PHPP worksheet IHG. First it must be noted that the fluctuation range of occupancy and IH
- Don’t save on the insulation @planning:thermal_protection
- vels are dealt with in the following list. Taking no action will be much more expensive than carrying out insulation measures here and now! This is shown by the feasibility study (see [[P... ch should be applied to thermal protection. * No exterior painting and improvement of the render w... s:Thermal protection vs. thermal storage]].\\ For now: the U-value has actually proved to be the decis
- Airtightness measurements in Passive Houses @planning:airtight_construction
- to ISO 9972, method 1. The deviations (these are not of a fundamental nature), clarifications and add... according to the procedure listed below which is not part of the ISO 9972. The resulting volume is to... tant ones are compared here: [{{ :picopen:000_bd_norm_bezeichnungen.jpg?400 |}}] ==== 2. Calculatio... ng etc. will have been completed already. It will not be possible to access many important connections
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
- Sound generation, sound dispersion and sound proofing in heat pumps @planning:building_services:heating_and_dhw:heating:heat_pumps
- PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Passive House refurbishment - thermal envelope @planning:refurbishment_with_passive_house_components