• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » no

no

Search

You can find the results of your search below.

Starts with
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning
  • Any namespace
  • planning:refurbishment_with_passive_house_components (15)
  • planning:building_services (12)
  • planning:thermal_protection (11)
  • planning:non-residential_passive_house_buildings (10)
  • planning:calculating_energy_efficiency (8)
  • planning:airtight_construction (6)
  • planning:guides_and_aids (2)
  • planning:planning (1)
  • planning:summer_comfort (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • Non-residential Passive House buildings
  • Introduction: Retail stores as Passive Houses
  • Passive House schools
  • Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
  • The ventilation system – there is no alternative
  • Variant calculations and economic assessment with PHPP 9
  • Energy efficiency in cafeterias and commercial kitchens
  • Ventilation in commercial kitchens
  • Passive House schools – How to go about it
  • Passive House Schools - Boundary Conditions
  • Aspects of efficient ventilation in hospitals
  • Baseline study - implementing the Passive House concept in hospitals
  • Passive House Hospitals
  • Passive House swimming pools
  • Outdoor thermography
  • Thermal protection in retrofits
  • Insulation works – Evidence no.1 "Measurements at a highly insulated wall"
  • Energy use for heating in a well insulated new building

Fulltext results:

Types of ventilation @planning:building_services:ventilation:basics
41 Hits, Last modified: 2 years ago
aced by fresh air. Opening windows twice a day is not enough (see [[[planning:building services:Ventil... ies for ordinary new buildings. The issue here is not energy efficiency, but the health of the buildin... rgy conservation - but it turns out that there is no conflict at all, if efficient components are used... envelope ===== Gap ventilation through leaks is not adequate in the heating period at all (see also
Energy balances - Background @planning:calculating_energy_efficiency
40 Hits, Last modified: 5 years ago
he los-\\ ses as long as the internal energy does not change.**//|\\ \\ * An important note at this point: **The necessity for supplying heat arises on... ious and very effective. If the warmer system is not deliberately isolated ("thermally insulated"), m... which can be found, for example, in the European Norm EN 832 (now classified internationally as ISO13
Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
40 Hits, Last modified: 2 years ago
download/product_page/PH_Krankenhaus|here.]]** Note: The guide was developed in the German context ... ated into English. Therefore, the translation may not take into account international or country-speci... n Germany with a total of 503,422 beds [[planning:non-residential_passive_house_buildings:ph_hospitals... build for the Frankfurt Höchst Clinic [[planning:non-residential_passive_house_buildings:ph_hospitals
Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
39 Hits, Last modified: 8 years ago
iteria 1 to 9 as stated in the article [[planning:non-residential_passive_house_buildings:passive_hous... ith justifiable effort. These recommendations are not meant to be requirements – it is possible to dev... r achieving the Passive House standard [[planning:non-residential_passive_house_buildings:passive_hous... e achieved if the buildings are well-planned, and not unnecessarily broken up – which increases costs.
Non-residential Passive House buildings
37 Hits, Last modified: 14 months ago
====== Non-residential Passive House buildings ====== The Passive House Standard allows for extremely... s of comfort as well as enormous energy savings - not only for residential buildings. The Passive Hous... tandard and experiences gained from their use are now available: The Passive House Standards allows fo... age new school buildings - and of course there is no need for an additional heating or cooling system.
Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
33 Hits, Last modified: 5 years ago
port processes. The room model works with one air node and one radiation node, which are clearly separated from each other. Heat transmitted to interior s... ature and solar radiation in each period of time (nonlinear). The wall model uses not transfer functions but uses a forward difference method, thereby ful
Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
33 Hits, Last modified: 9 years ago
ent Situation ===== Refurbishment projects were not taken into account by the Spanish energy efficie... E) until 2013, when the CTE was updated, and till now comfort and efficiency are not measured in the compulsory technical inspections of existing building... f buildings in poor conditions. Their dwellers do not enjoy adequate comfort conditions or need a huge
Commercial kitchens and cafeterias
30 Hits, Last modified: 3 years ago
ation units to be used. [{{ :picopen:fig1_10.png?nolink&300 |View of the cooking area of a Passive Ho... i_publications:basic_principles]]** **[[planning:non-residential_passive_house_buildings:cafeterias_a... hen and cafeterias]]**{{:picopen:members_only.png?nolink&20|}} **[[planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens:en
Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
30 Hits, Last modified: 10 months ago
lead to increased energy consumption. This should not be confused with __air__tightness that is being ... Pressure test results of old buildings that have not been modernised are often in the range between 3... in a building that needs to be refurbished. It is not known what effect this will have on the airtight... an be incorporated into the new concept. \\ ==== Notes for implementation ==== If a particularly low
Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
29 Hits, Last modified: 3 years ago
{{:picopen:iee_.png?nolink }} [[http://europhit.eu|{{ :picopen:europhit_logo.png?nolink|}}]] \\ \\ \\ \\ \\ \\ ====== Internal heat ... smaller dwelling units (DU), as a result of which not only body heat from occupants but also the heat ... n from the PHPP worksheet IHG. First it must be noted that the fluctuation range of occupancy and IH
Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
29 Hits, Last modified: 4 years ago
fluger in the relevant Protocol Volume [[planning:non-residential_passive_house_buildings:passive_hous... ools_requirements#Literature|[AkkP 33] ]].This is nothing new; these findings had often been made duri... anical fresh air supply. The first alternative is not realistic in typical Central European winter con... be based on health and educational objectives and not on the upper limits of the comfort criteria. Th
Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
27 Hits, Last modified: 3 years ago
gains from solar radiation are insufficiently, or not at all, taken into account by scientists. The ... ty or the second law of thermodynamics) that have not been "proven". Strictly speaking, that is in fac... t has stood up to each test till today. This does not place the stand of scientific knowledge in the r... in the house.\\ \\ Simply stated: although it is not "absolutely" certain that the heat equation corr
Airtightness measurements in Passive Houses @planning:airtight_construction
26 Hits, Last modified: 2 years ago
to ISO 9972, method 1. The deviations (these are not of a fundamental nature), clarifications and add... according to the procedure listed below which is not part of the ISO 9972. The resulting volume is to... tant ones are compared here: [{{ :picopen:000_bd_norm_bezeichnungen.jpg?400 |}}] ==== 2. Calculatio... ng etc. will have been completed already. It will not be possible to access many important connections
Air volumes @planning:building_services:ventilation:basics
25 Hits, Last modified: 6 years ago
mes without ventilation systems), therefore it is not energy-relevant or practical! Of course, it is ... the quality of the external air, but in reality, noise caused by the air flow and draughts would have... or air humidity is the primary limiting factor if no humidification is planned for (increased effort f... at the systems are almost always operated at the "Normal" setting in spite of the fact that it is poss
Don’t save on the insulation @planning:thermal_protection
22 Hits, Last modified: 5 years ago
vels are dealt with in the following list. Taking no action will be much more expensive than carrying out insulation measures here and now! This is shown by the feasibility study (see [[P... ch should be applied to thermal protection. * No exterior painting and improvement of the render w... s:Thermal protection vs. thermal storage]].\\ For now: the U-value has actually proved to be the decis
Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
22 Hits, Last modified: 3 years ago
Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
21 Hits, Last modified: 7 years ago
Ventilation @planning:building_services
20 Hits, Last modified: 19 months ago
Thermal insulation @planning:thermal_protection
18 Hits, Last modified: 4 years ago
Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
18 Hits, Last modified: 3 years ago
Types of glazing and their specific values @planning:thermal_protection:windows
18 Hits, Last modified: 3 years ago
Windows in a step-by-step retrofit @planning:refurbishment_with_passive_house_components
16 Hits, Last modified: 9 years ago
Ventilation tools
14 Hits, Last modified: 4 years ago
Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
14 Hits, Last modified: 6 years ago
Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
13 Hits, Last modified: 6 years ago
Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
12 Hits, Last modified: 3 years ago
Outdoor thermography @planning:thermal_protection:thermal_protection_works
12 Hits, Last modified: 3 years ago
Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
11 Hits, Last modified: 6 years ago
Why build an airtight house? – Leakage problems @planning:airtight_construction:general_principles
11 Hits, Last modified: 6 years ago
Calculating energy efficiency
10 Hits, Last modified: 5 years ago
Climate data tool for the southern hemisphere
10 Hits, Last modified: 4 years ago
Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
10 Hits, Last modified: 5 years ago
Summer Comfort
9 Hits, Last modified: 22 months ago
Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
9 Hits, Last modified: 6 years ago
Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
9 Hits, Last modified: 7 years ago
Airtightness test @planning:airtight_construction:general_principles
9 Hits, Last modified: 7 years ago
Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
9 Hits, Last modified: 6 years ago
Window tools
8 Hits, Last modified: 11 months ago
Compact HVAC systems @planning:building_services
8 Hits, Last modified: 5 years ago
Passive House schools @planning:non-residential_passive_house_buildings
8 Hits, Last modified: 5 years ago
Thermal protection and modernisation of existing buildings @planning:planning
8 Hits, Last modified: 6 years ago
Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
8 Hits, Last modified: 6 years ago
Thermal protection works @planning:thermal_protection
8 Hits, Last modified: 6 years ago
Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
8 Hits, Last modified: 2 years ago
Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
8 Hits, Last modified: 6 years ago
PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
8 Hits, Last modified: 12 months ago
Thermal protection in retrofits @planning:thermal_protection:thermal_protection_works
8 Hits, Last modified: 11 years ago
PHPP – Passive House Planning Package @planning:calculating_energy_efficiency
7 Hits, Last modified: 12 months ago
PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
7 Hits, Last modified: 3 years ago
Cooling tools
6 Hits, Last modified: 11 months ago
Building envelope
6 Hits, Last modified: 11 months ago
Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
6 Hits, Last modified: 17 months ago
Passive House swimming pools @planning:non-residential_passive_house_buildings:swimming_pools
6 Hits, Last modified: 13 months ago
Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
6 Hits, Last modified: 6 years ago
Airtight construction
5 Hits, Last modified: 10 months ago
Climate tools
5 Hits, Last modified: 11 months ago
General principles for improving airtightness @planning:airtight_construction:general_principles
5 Hits, Last modified: 10 years ago
Supplying Passive Houses with sustainable energy @planning:building_services:heating_and_dhw
5 Hits, Last modified: 11 years ago
Differentiation between Vv and Vn50 values @planning:building_services:ventilation
5 Hits, Last modified: 2 years ago
Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
5 Hits, Last modified: 8 years ago
Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
5 Hits, Last modified: 6 years ago
Component guidelines for cost-optimal Passive Houses and EnerPHit retrofits
4 Hits, Last modified: 8 years ago
Airtightness Measurement of High-Rise Buildings @planning:airtight_construction
4 Hits, Last modified: 3 years ago
Planning Guidelines for Passive House Indoor Swimming Pools @planning:guides_and_aids
4 Hits, Last modified: 13 months ago
Summer Comfort Guideline @planning:summer_comfort
4 Hits, Last modified: 2 years ago
Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
4 Hits, Last modified: 23 months ago
Passive House Hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
4 Hits, Last modified: 21 months ago
Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
4 Hits, Last modified: 6 years ago
Sound generation, sound dispersion and sound proofing in heat pumps @planning:building_services:heating_and_dhw:heating:heat_pumps
4 Hits, Last modified: 7 years ago
Climate data tool
3 Hits, Last modified: 4 years ago
Design tools
3 Hits, Last modified: 11 months ago
PHLuft
3 Hits, Last modified: 3 years ago
Educational Buildings-Kindergarten-Sports Hall @planning:guides_and_aids
3 Hits, Last modified: 3 years ago
The ventilation system – there is no alternative @planning:building_services:ventilation
3 Hits, Last modified: 3 years ago
Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
3 Hits, Last modified: 6 years ago
Guides and Aids
2 Hits, Last modified: 12 months ago
Heat pump tools
2 Hits, Last modified: 11 months ago
Lift energy demand tool
2 Hits, Last modified: 4 years ago
PHErde
2 Hits, Last modified: 3 years ago
Pressure Loss Calculation Tool
2 Hits, Last modified: 2 years ago
Tools and calculation relating to sound protection
2 Hits, Last modified: 2 years ago
Thermal bridge tool
2 Hits, Last modified: 4 years ago
Passive House refurbishment - ventilation @planning:refurbishment_with_passive_house_components
2 Hits, Last modified: 7 years ago
PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
2 Hits, Last modified: 6 years ago
Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
2 Hits, Last modified: 6 years ago
Building Services
1 Hits, Last modified: 24 months ago
Cooling Systems tool
1 Hits, Last modified: 4 years ago
Electricity tools
1 Hits, Last modified: 11 months ago
Hygiene tool
1 Hits, Last modified: 4 years ago
Thermal bridges tools
1 Hits, Last modified: 11 months ago
Tools
1 Hits, Last modified: 10 months ago
Ventilation tool
1 Hits, Last modified: 4 years ago
Window tool
1 Hits, Last modified: 4 years ago
Heating and DHW @planning:building_services
1 Hits, Last modified: 7 years ago
Passive House refurbishment - thermal envelope @planning:refurbishment_with_passive_house_components
1 Hits, Last modified: 7 years ago
Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
1 Hits, Last modified: 4 years ago

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN