Fulltext results:
- Types of ventilation @planning:building_services:ventilation:basics
- aced by fresh air. Opening windows twice a day is not enough (see [[[planning:building services:Ventil... ies for ordinary new buildings. The issue here is not energy efficiency, but the health of the buildin... rgy conservation - but it turns out that there is no conflict at all, if efficient components are used... envelope ===== Gap ventilation through leaks is not adequate in the heating period at all (see also
- Energy balances - Background @planning:calculating_energy_efficiency
- he los-\\ ses as long as the internal energy does not change.**//|\\ \\ * An important note at this point: **The necessity for supplying heat arises on... ious and very effective. If the warmer system is not deliberately isolated ("thermally insulated"), m... which can be found, for example, in the European Norm EN 832 (now classified internationally as ISO13
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- download/product_page/PH_Krankenhaus|here.]]** Note: The guide was developed in the German context ... ated into English. Therefore, the translation may not take into account international or country-speci... n Germany with a total of 503,422 beds [[planning:non-residential_passive_house_buildings:ph_hospitals... build for the Frankfurt Höchst Clinic [[planning:non-residential_passive_house_buildings:ph_hospitals
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- iteria 1 to 9 as stated in the article [[planning:non-residential_passive_house_buildings:passive_hous... ith justifiable effort. These recommendations are not meant to be requirements – it is possible to dev... r achieving the Passive House standard [[planning:non-residential_passive_house_buildings:passive_hous... e achieved if the buildings are well-planned, and not unnecessarily broken up – which increases costs.
- Non-residential Passive House buildings
- ====== Non-residential Passive House buildings ====== The Passive House Standard allows for extremely... s of comfort as well as enormous energy savings - not only for residential buildings. The Passive Hous... tandard and experiences gained from their use are now available: The Passive House Standards allows fo... age new school buildings - and of course there is no need for an additional heating or cooling system.
- Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
- port processes. The room model works with one air node and one radiation node, which are clearly separated from each other. Heat transmitted to interior s... ature and solar radiation in each period of time (nonlinear). The wall model uses not transfer functions but uses a forward difference method, thereby ful
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- ent Situation ===== Refurbishment projects were not taken into account by the Spanish energy efficie... E) until 2013, when the CTE was updated, and till now comfort and efficiency are not measured in the compulsory technical inspections of existing building... f buildings in poor conditions. Their dwellers do not enjoy adequate comfort conditions or need a huge
- Commercial kitchens and cafeterias
- ation units to be used. [{{ :picopen:fig1_10.png?nolink&300 |View of the cooking area of a Passive Ho... i_publications:basic_principles]]** **[[planning:non-residential_passive_house_buildings:cafeterias_a... hen and cafeterias]]**{{:picopen:members_only.png?nolink&20|}} **[[planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens:en
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- lead to increased energy consumption. This should not be confused with __air__tightness that is being ... Pressure test results of old buildings that have not been modernised are often in the range between 3... in a building that needs to be refurbished. It is not known what effect this will have on the airtight... an be incorporated into the new concept. \\ ==== Notes for implementation ==== If a particularly low
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- {{:picopen:iee_.png?nolink }} [[http://europhit.eu|{{ :picopen:europhit_logo.png?nolink|}}]] \\ \\ \\ \\ \\ \\ ====== Internal heat ... smaller dwelling units (DU), as a result of which not only body heat from occupants but also the heat ... n from the PHPP worksheet IHG. First it must be noted that the fluctuation range of occupancy and IH
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- fluger in the relevant Protocol Volume [[planning:non-residential_passive_house_buildings:passive_hous... ools_requirements#Literature|[AkkP 33] ]].This is nothing new; these findings had often been made duri... anical fresh air supply. The first alternative is not realistic in typical Central European winter con... be based on health and educational objectives and not on the upper limits of the comfort criteria. Th
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- gains from solar radiation are insufficiently, or not at all, taken into account by scientists. The ... ty or the second law of thermodynamics) that have not been "proven". Strictly speaking, that is in fac... t has stood up to each test till today. This does not place the stand of scientific knowledge in the r... in the house.\\ \\ Simply stated: although it is not "absolutely" certain that the heat equation corr
- Airtightness measurements in Passive Houses @planning:airtight_construction
- to ISO 9972, method 1. The deviations (these are not of a fundamental nature), clarifications and add... according to the procedure listed below which is not part of the ISO 9972. The resulting volume is to... tant ones are compared here: [{{ :picopen:000_bd_norm_bezeichnungen.jpg?400 |}}] ==== 2. Calculatio... ng etc. will have been completed already. It will not be possible to access many important connections
- Air volumes @planning:building_services:ventilation:basics
- mes without ventilation systems), therefore it is not energy-relevant or practical! Of course, it is ... the quality of the external air, but in reality, noise caused by the air flow and draughts would have... or air humidity is the primary limiting factor if no humidification is planned for (increased effort f... at the systems are almost always operated at the "Normal" setting in spite of the fact that it is poss
- Don’t save on the insulation @planning:thermal_protection
- vels are dealt with in the following list. Taking no action will be much more expensive than carrying out insulation measures here and now! This is shown by the feasibility study (see [[P... ch should be applied to thermal protection. * No exterior painting and improvement of the render w... s:Thermal protection vs. thermal storage]].\\ For now: the U-value has actually proved to be the decis
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
- Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- Sound generation, sound dispersion and sound proofing in heat pumps @planning:building_services:heating_and_dhw:heating:heat_pumps
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
- PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package